Return to study ST002862 main page
MB Sample ID: SA309345
Local Sample ID: | A_76 |
Subject ID: | SU002974 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU002974 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
A_76 | SA309345 | FL037197 | high-altitude group | Treatment |
Collection:
Collection ID: | CO002967 |
Collection Summary: | Fecal samples were collected from participants using fecal sampling tubes (Shenzhen Medico Biomedical Technology Co., Ltd) and were also stored at -80°C after sampling. |
Sample Type: | Feces |
Treatment:
Treatment ID: | TR002983 |
Treatment Summary: | The study enrolled two distinct groups: a plain group (PL) comprising 67 adult males from the Chengdu plain in Sichuan, and a high-altitude group (HA) comprising 163 adult males from Tibet residing at altitudes ranging from 3500m to 4500m. They were all graduated from Chengdu Medical College and enrolled in this study with the patients' consent and the sampling process was strictly consistent.The study received approval from the Ethics Committee of the Academy of Military Medicine, Chinese Academy of Military Sciences, with the approval number AF/SC-08/02.153. |
Sample Preparation:
Sampleprep ID: | SP002980 |
Sampleprep Summary: | For fecal samples, 60mg of the sample was mixed with 600μL of 80% iced methanol, which included 0.001mg/mL 4-chloro-DL-phenylalanine as an internal standard. Zirconia crushing beads were added to the mixture, and the samples were disrupted using a vibratory crusher operating at 60 hertz. Subsequently, the samples were processed by ultrasonication in an ice bath for 10 minutes and left to stand at -20℃ for 30 minutes. The supernatants were collected by centrifugation at 20,000 g under 4 C for 10 minutes and then mixed with three-fold volumes of distilled water. After ultrasonication for 3 minutes to ensure even mixing, the samples were placed in a -20℃ environment for 2 hours. Finally, the supernatants obtained from centrifugation were transferred to sample vials for metabolomics analysis |
Combined analysis:
Analysis ID | AN004693 | AN004694 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Agilent 1290 Infinity | Agilent 1290 Infinity |
Column | Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,1.8um) | Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,1.8um) |
MS Type | ESI | ESI |
MS instrument type | Triple quadrupole | Triple quadrupole |
MS instrument name | Agilent 6495 QQQ | Agilent 6495 QQQ |
Ion Mode | POSITIVE | NEGATIVE |
Units | counts | counts |
Chromatography:
Chromatography ID: | CH003534 |
Chromatography Summary: | In this study, a newly developed precision-targeted metabolomics method with a UPLC-TQ/MS system (Agilent 1290 Infnity, Agilent Technologies, USA; Agilent 6495 QQQ, Agilent Technologies, USA) in a DMRM scan-mode was applied to analyze the metabolome of interest from trial samples (serum, liver tissues and stool). Briefly, the method was performed with an ACQUITY UPLC HSS T3 column (2.1 mm i.d. × 100 mm, 1.8 μm; Waters); mobile phase A and B were water and acetonitrile with 0.1% formic acid (v/v) respectively. The flow rate was at 0.3 mL/min and the column temperature was maintained at 40 ℃. The samples were placed in an auto-sampler maintained at 4 °C with a 5 μL injection volume. The optimized gradient-elution program, as follows: 0-2 min, 98% A; 2-10 min, 98-65% A; 10-12 min, 65-20% A; 12-14 min, 20-2% A; 14-30 min, 2% A. |
Methods Filename: | Chromatography.pdf |
Instrument Name: | Agilent 1290 Infinity |
Column Name: | Waters ACQUITY UPLC HSS T3 (100 x 2.1mm,1.8um) |
Column Temperature: | 40 ℃ |
Flow Gradient: | 0-2 minutes, 98% A 2-10 minutes, 98%-65% A 10-12 minutes, 65%-20% A 12-14 minutes, 20%-2% A 14-30 minutes, 2% A. |
Flow Rate: | 0.3 ml/min |
Solvent A: | 100% water + 0.1% formic acid |
Solvent B: | 100% acetonitrile + 0.1% formic acid |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS004440 |
Analysis ID: | AN004693 |
Instrument Name: | Agilent 6495 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Agilent MassHunter Workstation Data Acquisition Agilent MassHunter |
Ion Mode: | POSITIVE |
Analysis Protocol File: | MS.pdf |
MS ID: | MS004441 |
Analysis ID: | AN004694 |
Instrument Name: | Agilent 6495 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Agilent MassHunter Workstation Data Acquisition Agilent MassHunter |
Ion Mode: | NEGATIVE |
Analysis Protocol File: | MS.pdf |