Return to study ST001048 main page
MB Sample ID: SA071175
Local Sample ID: | C-1FTD1-U-00 |
Subject ID: | SU001090 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN001716 | AN001717 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | Reversed phase |
Chromatography system | Agilent 1290 Infinity II | Agilent 1290 Infinity II |
Column | SeQuant ZIC-pHILIC (100 x 2.1mm,3.5um) | Agilent Zorbax Eclipse Plus C18 (50 x 2.1mm, 1.8 um) |
MS Type | ESI | ESI |
MS instrument type | QTOF | QTOF |
MS instrument name | Agilent 6550 QTOF | Agilent 6550 QTOF |
Ion Mode | POSITIVE | NEGATIVE |
Units | Peak Intensity | Peak Intensity |
Chromatography:
Chromatography ID: | CH001212 |
Chromatography Summary: | Sample extracts were analyzed using an ultra-high performance liquid chromatography (UHPLC) 1290 Infinity II system (including 0.3 µm inline filter, Agilent Technologies, Santa Clara, USA) with 1260 Infinity II isocratic pump (including 1:100 splitter) coupled to a 6550 iFunnel quadrupole-time time of flight (Q-TOF) mass spectrometer with a dual AJS electrospray ionization source (Agilent Technologies, Santa Clara, USA). Samples were maintained at 5C in the autosampler module. For polar metabolites separation, 2 uL of sample was injected onto a HILIC SeQuant® ZIC®-HILIC column (100 mm × 2.1 mm, 100 Å, 3.5 µm particle size, Merck, Darmstadt, Germany) with a guard fitting (14 mm × 1 mm, 5.0 µm particle size, Merck, Darmstadt, Germany) maintained at 25C. Separation occurred using Mobile phase A consisted of water with 0.1% formic acid and Mobile phase B consisted of Acetonitrile with 0.1% formic acid at a flow rate of 0.3 ml/min as described in Table 1. Data was acquired with a mass range of 40-1200 m/z. Solvent gradients were as follows: 95% solvent B, hold for 1.5 min; linear decrease to 40% solvent B at 12 minutes; hold for 2 min, linear decrease to 25% solvent B at 14.2 min, hold for 2.8 min; increase to 95% solvent B at 18 min, hold for 7 min. |
Instrument Name: | Agilent 1290 Infinity II |
Column Name: | SeQuant ZIC-pHILIC (100 x 2.1mm,3.5um) |
Column Temperature: | 25C |
Flow Rate: | 0.3 mL/min |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% acetonitrile; 0.1% formic acid |
Analytical Time: | 25 min |
Chromatography Type: | HILIC |
Chromatography ID: | CH001213 |
Chromatography Summary: | Sample extracts were analyzed using an ultra-high performance liquid chromatography (UHPLC) 1290 Infinity II system (including 0.3 µm inline filter, Agilent Technologies, Santa Clara, USA) with 1260 Infinity II isocratic pump (including 1:100 splitter) coupled to a 6550 iFunnel quadrupole-time time of flight (Q-TOF) mass spectrometer with a dual AJS electrospray ionization source (Agilent Technologies, Santa Clara, USA). Samples were maintained at 5C in the autosampler module. For nonpolar metabolites separation, 2 uL of sample sandwiched between 10 uL of water was injected onto a Zorbax Eclipse Plus C18, RRHD column (50 mm × 2.1 mm, 1.8 µm particle size, Agilent Technologies, Santa Clara, USA) coupled to a guard column (5 mm × 2 mm, 1.8 µm Agilent Technologies, Santa Clara, USA) maintained at 50C. Separation occurred using Mobile phase A consisted of water with 0.1% formic acid and Mobile phase B consisted of 2-propanol:ACN (90:10, v/v) with 0.1% formic acid at a flow rate of 0.4 ml/min as described in Table 2. Data was acquired with a mass range of 50-1200 m/z. Solvent gradients were as follows: 5% solvent B; linear increase to 98% solvent B at 13.5 min, hold for 1.5 min; decrease to 5% solvent B at 15.5 min, hold for 3.5 min. |
Instrument Name: | Agilent 1290 Infinity II |
Column Name: | Agilent Zorbax Eclipse Plus C18 (50 x 2.1mm, 1.8 um) |
Column Temperature: | 50C |
Flow Rate: | 0.4 mL/min |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 90% isopropanol/10% acetonitrile; 0.1% formic acid |
Analytical Time: | 19 min |
Chromatography Type: | Reversed phase |