Return to study ST000422 main page
MB Sample ID: SA021450
Local Sample ID: | 15feb12_38-r002.d |
Subject ID: | SU000443 |
Subject Type: | Animal |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Species Group: | Human |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN000667 | AN000668 | AN000669 | AN000670 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | HILIC | HILIC | Reversed phase | Reversed phase |
Chromatography system | Agilent 6220 | Agilent 6220 | Agilent 6220 | Agilent 6220 |
Column | none | none | none | none |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | TOF | TOF | TOF | TOF |
MS instrument name | Agilent 6220 TOF | Agilent 6220 TOF | Agilent 6220 TOF | Agilent 6220 TOF |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | intensity | intensity | intensity | intensity |
MS:
MS ID: | MS000593 |
Analysis ID: | AN000667 |
Instrument Name: | Agilent 6220 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
Ion Mode: | POSITIVE |
Capillary Temperature: | 300°C |
Capillary Voltage: | 3.5 kV |
Fragment Voltage: | 150 V |
Mass Accuracy: | <5 parts per million and ~20000 respectively |
Nebulizer: | nebulizer gas 325°C |
Octpole Voltage: | 250 V |
Scan Range Moverz: | 50-1200 |
Scanning Cycle: | 0.5 s |
Skimmer Voltage: | 58 V |
MS ID: | MS000594 |
Analysis ID: | AN000668 |
Instrument Name: | Agilent 6220 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
Ion Mode: | NEGATIVE |
Capillary Temperature: | 300°C |
Capillary Voltage: | 3.5 kV |
Fragment Voltage: | 150 V |
Mass Accuracy: | <5 parts per million and ~20000 respectively |
Nebulizer: | nebulizer gas 325°C |
Octpole Voltage: | 250 V |
Scan Range Moverz: | 50-1200 |
Scanning Cycle: | 0.5 s |
Skimmer Voltage: | 58 V |
MS ID: | MS000595 |
Analysis ID: | AN000669 |
Instrument Name: | Agilent 6220 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
Ion Mode: | POSITIVE |
Capillary Temperature: | 300°C |
Capillary Voltage: | 3.5 kV |
Fragment Voltage: | 150 V |
Mass Accuracy: | <5 parts per million and ~20000 respectively |
Nebulizer: | nebulizer gas 325°C |
Octpole Voltage: | 250 V |
Scan Range Moverz: | 50-1200 |
Scanning Cycle: | 0.5 s |
Skimmer Voltage: | 58 V |
MS ID: | MS000596 |
Analysis ID: | AN000670 |
Instrument Name: | Agilent 6220 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
Ion Mode: | NEGATIVE |
Capillary Temperature: | 300°C |
Capillary Voltage: | 3.5 kV |
Fragment Voltage: | 150 V |
Mass Accuracy: | <5 parts per million and ~20000 respectively |
Nebulizer: | nebulizer gas 325°C |
Octpole Voltage: | 250 V |
Scan Range Moverz: | 50-1200 |
Scanning Cycle: | 0.5 s |
Skimmer Voltage: | 58 V |