MB Sample ID: SA322961
Local Sample ID: | MB-C1 |
Subject ID: | SU003079 |
Subject Type: | Plant |
Subject Species: | Corydalis yanhusuo |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004873 | AN004874 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | HILIC |
Chromatography system | SHIMADZU Nexera X2 | SHIMADZU Nexera X2 |
Column | Agilent ZORBAX RRHD SB-C18 (100 x 2.1mm,1.8um) | Agilent ZORBAX RRHD SB-C18 (100 x 2.1mm,1.8um) |
MS Type | ESI | APCI |
MS instrument type | Triple quadrupole | Triple quadrupole |
MS instrument name | ABI Sciex API 4000 QTrap | ABI Sciex API 4000 QTrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | peak area | peak area |
MS:
MS ID: | MS004617 |
Analysis ID: | AN004873 |
Instrument Name: | ABI Sciex API 4000 QTrap |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | LIT and triple quadrupole (QQQ) scans were acquired on a triple quadrupole-linear ion trap mass spectrometer (Q TRAP), AB4500 Q TRAP UPLC/MS/MS System, equipped with an ESI Turbo Ion-Spray interface, operating in positive and negative ion mode and controlled by Analyst 1.6.3 software (AB Sciex). The ESI source operation parameters were as follows: ion source, turbo spray; source temperature 550°C; ion spray voltage (IS) 5500 V (positive ion mode)/-4500 V (negative ion mode); ion source gas I (GSI), gas II(GSII), curtain gas (CUR) were set at 50, 60, and 25.0 psi, respectively; the collision-activated dissociation(CAD) was high. Instrument tuning and mass calibration were performed with 10 and 100 μmol/L polypropylene glycol solutions in QQQ and LIT modes, respectively. QQQ scans were acquired as MRM experiments with collision gas (nitrogen) set to medium. DP and CE for individual MRM transitions was done with further DP and CE optimization. A specific set of MRM transitions were monitored for each period according to the metabolites eluted within this period. |
Ion Mode: | POSITIVE |
MS ID: | MS004618 |
Analysis ID: | AN004874 |
Instrument Name: | ABI Sciex API 4000 QTrap |
Instrument Type: | Triple quadrupole |
MS Type: | APCI |
MS Comments: | LIT and triple quadrupole (QQQ) scans were acquired on a triple quadrupole-linear ion trap mass spectrometer (Q TRAP), AB4500 Q TRAP UPLC/MS/MS System, equipped with an ESI Turbo Ion-Spray interface, operating in positive and negative ion mode and controlled by Analyst 1.6.3 software (AB Sciex). The ESI source operation parameters were as follows: ion source, turbo spray; source temperature 550°C; ion spray voltage (IS) 5500 V (positive ion mode)/-4500 V (negative ion mode); ion source gas I (GSI), gas II(GSII), curtain gas (CUR) were set at 50, 60, and 25.0 psi, respectively; the collision-activated dissociation(CAD) was high. Instrument tuning and mass calibration were performed with 10 and 100 μmol/L polypropylene glycol solutions in QQQ and LIT modes, respectively. QQQ scans were acquired as MRM experiments with collision gas (nitrogen) set to medium. DP and CE for individual MRM transitions was done with further DP and CE optimization. A specific set of MRM transitions were monitored for each period according to the metabolites eluted within this period. |
Ion Mode: | NEGATIVE |