Return to study ST003108 main page
MB Sample ID: SA333682
Local Sample ID: | DS1-095-010L+ |
Subject ID: | SU003223 |
Subject Type: | Cultured cells |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN005087 | AN005088 | AN005089 | AN005090 |
---|---|---|---|---|
Analysis type | MS | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish | Thermo Vanquish | Thermo Vanquish |
Column | Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) | Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) | Phenomenex Kinetex C18 (30 x 2.1mm, 1.7um) | Phenomenex Kinetex C18 (30 x 2.1mm, 1.7um) |
MS Type | ESI | ESI | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE | POSITIVE | NEGATIVE |
Units | area | area | area | area |
MS:
MS ID: | MS004824 |
Analysis ID: | AN005087 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | El-Maven used for data analysis. Orbitrap scanning in full MS mode from 65-975 m/z at 60,000 resolution, with 50 Arb sheath gas, 10 Arb auxiliary gas, and 3.4 kV spray voltage. |
Ion Mode: | POSITIVE |
MS ID: | MS004825 |
Analysis ID: | AN005088 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | El-Maven used for data analysis. Orbitrap scanning in full MS mode from 65-975 m/z at 60,000 resolution, with 50 Arb sheath gas, 10 Arb auxiliary gas, and 3 kV spray voltage. |
Ion Mode: | NEGATIVE |
MS ID: | MS004826 |
Analysis ID: | AN005089 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Lipidsearch used for data analysis. Orbitrap scanning using data dependent MS2 (top 10) from 125-1500 m/z at 17,500 resolution, with 45 Arb sheath gas, 25 Arb auxiliary gas, and 4 kV spray voltage. |
Ion Mode: | POSITIVE |
MS ID: | MS004827 |
Analysis ID: | AN005090 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Lipidsearch used for data analysis. Orbitrap scanning using data dependent MS2 (top 10) from 125-1500 m/z at 17,500 resolution, with 45 Arb sheath gas, 25 Arb auxiliary gas, and 4 kV spray voltage. |
Ion Mode: | NEGATIVE |