Return to study ST002930 main page
MB Sample ID: SA318102
| Local Sample ID: | HIF KO C2C12 UnT1 M_Dasarathy_Nicole_114Cells_02042022_HILIC_POS249 |
| Subject ID: | SU003043 |
| Subject Type: | Cultured cells |
| Subject Species: | Mus musculus |
| Taxonomy ID: | 10090 |
| Age Or Age Range: | Passage 4-8 |
| Gender: | Female |
| Species Group: | Mammals |
Select appropriate tab below to view additional metadata details:
Subject:
| Subject ID: | SU003043 |
| Subject Type: | Cultured cells |
| Subject Species: | Mus musculus |
| Taxonomy ID: | 10090 |
| Age Or Age Range: | Passage 4-8 |
| Gender: | Female |
| Species Group: | Mammals |
Factors:
| Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
|---|---|---|---|---|
| HIF KO C2C12 UnT1 M_Dasarathy_Nicole_114Cells_02042022_HILIC_POS249 | SA318102 | FL037859 | HIF1a KO | Genotype |
| HIF KO C2C12 UnT1 M_Dasarathy_Nicole_114Cells_02042022_HILIC_POS249 | SA318102 | FL037859 | Untreated | Treatment |
Collection:
| Collection ID: | CO003036 |
| Collection Summary: | Metabolites were extracted from myotubes and skeletal muscle using chilled methanol containing 6 labeled internal standards (Betaine-d9, Carnitine-d9, Estrone-13C3, Cholesterol-13C3, Valeric acid-d9, Choline-d13). After centrifugation at 14,000g for 20 minutes to precipitate the protein pellet, the supernatant was removed, dried, and reconstituted in 5% acetonitrile. LC/MS (liquid chromatography/mass spectrometry) analysis was then performed, including on pooled quality control samples. |
| Sample Type: | Skeletal myotubes |
Treatment:
| Treatment ID: | TR003052 |
| Treatment Summary: | Cells were not treated (Untreated, UnT) |
Sample Preparation:
| Sampleprep ID: | SP003049 |
| Sampleprep Summary: | Metabolites were extracted from myotubes and skeletal muscle using chilled methanol containing 6 labeled internal standards (Betaine-d9, Carnitine-d9, Estrone-13C3, Cholesterol-13C3, Valeric acid-d9, Choline-d13). After centrifugation at 14,000g for 20 minutes to precipitate the protein pellet, the supernatant was removed, dried, and reconstituted in 5% acetonitrile. LC/MS (liquid chromatography/mass spectrometry) analysis was then performed, including on pooled quality control samples. |
Combined analysis:
| Analysis ID | AN004807 | AN004808 |
|---|---|---|
| Chromatography ID | CH003633 | CH003633 |
| MS ID | MS004553 | MS004554 |
| Analysis type | MS | MS |
| Chromatography type | HILIC | HILIC |
| Chromatography system | Thermo Vanquish | Thermo Vanquish |
| Column | Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um) | Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um) |
| MS Type | ESI | ESI |
| MS instrument type | QTRAP | QTRAP |
| MS instrument name | Thermo Q Exactive Focus | Thermo Q Exactive Focus |
| Ion Mode | POSITIVE | NEGATIVE |
| Units | relative abundance | relative abundance |
Chromatography:
| Chromatography ID: | CH003633 |
| Instrument Name: | Thermo Vanquish |
| Column Name: | Waters ACQUITY UPLC BEH Amide (150 x 2.1mm,1.7um) |
| Column Temperature: | 40 |
| Flow Gradient: | Time (min.) Flow Rate (mL/min) %B 0.0 0.2 100 2.0 0.2 70 4.0 0.2 60 5.5 0.2 60 10.5 0.2 50 11.5 0.2 50 12.0 0.2 100 16.0 0.2 100 |
| Flow Rate: | 0.2 mL/min |
| Solvent A: | 100% water;10 mM ammonium acetate; 0.125% acetic acid |
| Solvent B: | 5% water/95% acetonitrile;10 mM ammonium acetate; 0.125% acetic acid |
| Chromatography Type: | HILIC |
MS:
| MS ID: | MS004553 |
| Analysis ID: | AN004807 |
| Instrument Name: | Thermo Q Exactive Focus |
| Instrument Type: | QTRAP |
| MS Type: | ESI |
| MS Comments: | Data dependent acquisitions (DDA) on the pooled representative QC samples include MS full scans at a resolution of 120,000 and HCD MS/MS scans taken on the top 5 most abundant ions at a resolution of 30,000 with dynamic exclusion. The resolution of the MS2 scans were taken at a stepped NCE energy of 10.0, 20.0 and 30.0. |
| Ion Mode: | POSITIVE |
| MS ID: | MS004554 |
| Analysis ID: | AN004808 |
| Instrument Name: | Thermo Q Exactive Focus |
| Instrument Type: | QTRAP |
| MS Type: | ESI |
| MS Comments: | Data dependent acquisitions (DDA) on the pooled representative QC samples include MS full scans at a resolution of 120,000 and HCD MS/MS scans taken on the top 5 most abundant ions at a resolution of 30,000 with dynamic exclusion. The resolution of the MS2 scans were taken at a stepped NCE energy of 10.0, 20.0 and 30.0. |
| Ion Mode: | NEGATIVE |