Return to study ST001521 main page

MB Sample ID: SA128035

Local Sample ID:9003-2-PE
Subject ID:SU001595
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:20-60
Weight Or Weight Range:BMI range: 20-35
Gender:Male and female
Human Race:White; American Indian/Alaskan Native; Black/African American
Human Ethnicity:Hispanic or Latino; Non-Hispanic or Latino
Human Trial Type:Intervention trial
Human Exclusion Criteria:Key exclusion criteria included inflammatory bowel disease, celiac disease, or other chronic intestinal disorders; prior bowel resection surgery other than appendectomy; baseline bowel frequency less than every 2 days or greater than 3 times daily; creatinine concentration greater than the upper limit of normal; diabetes mellitus; currently smoking; body mass index (BMI) <18.5 or >35; and use of antibiotics and probiotics in the prior 6 months

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002533 AN002534 AN002535 AN002536
Analysis type MS MS MS MS
Chromatography type HILIC Reversed phase HILIC Reversed phase
Chromatography system Shimadzu Nexera X2 Shimadzu Nexera X2 Shimadzu Nexera X2 Shimadzu Nexera X2
Column Waters Atlantis HILIC (150 x 2mm,3um) Waters Acquity BEH C8 (100 x 2.1mm,1.7um) Phenomenex Luna NH2 (150 x 2.1mm,3um) Waters Acquity T3 (150 x 2.1 mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Exactive Plus Orbitrap Thermo Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE POSITIVE NEGATIVE NEGATIVE
Units unitless peak areas unitless peak areas unitless peak areas unitless peak areas

MS:

MS ID:MS002351
Analysis ID:AN002533
Instrument Name:Thermo Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS analyses were carried out using electrospray ionization in the positive ion mode using full scan analysis over m/z 70-800 at 70,000 resolution and 3 Hz data acquisition rate. Additional MS settings were: ion spray voltage, 3.5 kV; capillary temperature, 350°C; probe heater temperature, 300°C; sheath gas, 40; auxiliary gas, 15; and S-lens RF level 40. All raw data were processed using Progenesis QI software (NonLinear Dynamics) for feature alignment, nontargeted signal detection, and signal integration. Targeted processing of a subset of known metabolites was conducted using TraceFinder software (Thermo Fisher Scientific; Waltham, MA). Compound identities were confirmed using reference standards
Ion Mode:POSITIVE
  
MS ID:MS002352
Analysis ID:AN002534
Instrument Name:Thermo Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS analyses were carried out using electrospray ionization in the positive ion mode using full scan analysis over m/z 200-1100 at 70,000 resolution and 3 Hz data acquisition rate. Additional MS settings were: ion spray voltage, 3.0 kV; capillary temperature, 300°C; probe heater temperature, 300°C; sheath gas, 50; auxiliary gas, 15; and S-lens RF level 60. All raw data were processed using Progenesis QI software (NonLinear Dynamics) for feature alignment, nontargeted signal detection, and signal integration. Targeted processing of a subset of known lipids was conducted using TraceFinder software (Thermo Fisher Scientific; Waltham, MA). Lipid identities were confirmed using reference standards representative of different lipid classes and previously characterized reference samples. Lipids were denoted by headgroup and total acyl carbon number and double bond content.
Ion Mode:POSITIVE
  
MS ID:MS002353
Analysis ID:AN002535
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS analyses were carried out using electrospray ionization in the negative ion mode using full scan analysis over m/z 60-750 at 70,000 resolution and 3 Hz data acquisition rate. Additional MS settings were: ion spray voltage, -3.0 kV; capillary temperature, 350°C; probe heater temperature, 325°C; sheath gas, 55; auxiliary gas, 10; and S-lens RF level 40. All raw data were processed using Progenesis QI software (NonLinear Dynamics) for feature alignment, nontargeted signal detection, and signal integration. Targeted processing of a subset of known metabolites was conducted using TraceFinder software (Thermo Fisher Scientific; Waltham, MA). Compound identities were confirmed using reference standards.
Ion Mode:NEGATIVE
  
MS ID:MS002354
Analysis ID:AN002536
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS analyses were carried out using electrospray ionization in the negative ion mode using full scan analysis over m/z 70-850 at 70,000 resolution and 3 Hz data acquisition rate. Additional MS settings were: ion spray voltage, -3.5 kV; capillary temperature, 320°C; probe heater temperature, 300°C; sheath gas, 45; auxiliary gas, 10; and S-lens RF level 60All raw data were processed using Progenesis QI software (NonLinear Dynamics) for feature alignment, nontargeted signal detection, and signal integration. Targeted processing of a subset of known metabolites was conducted using TraceFinder software (Thermo Fisher Scientific; Waltham, MA). Compound identities were confirmed using reference standards.
Ion Mode:NEGATIVE