MB Sample ID: SA320903
Local Sample ID: | WT1 |
Subject ID: | SU003060 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Species Group: | Mammals |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004832 | AN004833 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Reversed phase | Reversed phase |
Chromatography system | Thermo Vanquish | Thermo Vanquish |
Column | Thermo Accucore C30 (150 x 2.1mm,2.6um) | Thermo Accucore C30 (150 x 2.1mm,2.6um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Orbitrap Exploris 120 | Thermo Orbitrap Exploris 120 |
Ion Mode | POSITIVE | NEGATIVE |
Units | Peak Area | Peak Area |
MS:
MS ID: | MS004578 |
Analysis ID: | AN004832 |
Instrument Name: | Thermo Orbitrap Exploris 120 |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The mass spectrometry analysis was processed using an Orbitrap Exploris 120 mass spectrometer Thermo Fisher (Waltham, MA, USA) equipped with a HESI II probe in polar switching mode with source parameters set as follows: sheath gas flow rate, 60; auxiliary gas flow rate, 17; sweep gas flow rate, 1; spray voltage,+3.5/-3.0 kV; capillary temperature, 275 oC; S-lens RF level, 70; and heater temperature, 325 °C. Data was collected at dd-MS2 mode. Data analysis was performed using Lipidsearch (Thermofisher Scientific/Mitsui Knowledge Industries) with the default parameters for Orbitrap MS Product Search and Alignment. After alignment, raw peak areas for all identified lipids were exported to Excel files. |
Ion Mode: | POSITIVE |
MS ID: | MS004579 |
Analysis ID: | AN004833 |
Instrument Name: | Thermo Orbitrap Exploris 120 |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The mass spectrometry analysis was processed using an Orbitrap Exploris 120 mass spectrometer Thermo Fisher (Waltham, MA, USA) equipped with a HESI II probe in polar switching mode with source parameters set as follows: sheath gas flow rate, 60; auxiliary gas flow rate, 17; sweep gas flow rate, 1; spray voltage,+3.5/-3.0 kV; capillary temperature, 275 oC; S-lens RF level, 70; and heater temperature, 325 °C. Data was collected at dd-MS2 mode. Data analysis was performed using Lipidsearch (Thermofisher Scientific/Mitsui Knowledge Industries) with the default parameters for Orbitrap MS Product Search and Alignment. After alignment, raw peak areas for all identified lipids were exported to Excel files. |
Ion Mode: | NEGATIVE |