Summary of Study ST000287

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000229. The data can be accessed directly via it's Project DOI: 10.21228/M8259N This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files
Study IDST000287
Study TitleEnergetics in dystrophic muscle
Study TypeCross-sectional
Study SummaryThis project utilizes mouse models to establish whether lack of sarcolemma-localized nNOS impairs muscle metabolism and perfusion.
Institute
University of Florida
DepartmentSECIM
LaboratoryMuscle Physiology Laboratory
Last NameForbes
First NameSean
AddressUniversity of Florida, College of Public Health & Health Professions, Department of Physical Therapy, Box 100154, UFHSC
Emailscforbes@ufl.edu
Phone352-273-6111
Submit Date2015-09-30
Num Groups4
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2016-12-22
Release Version1
Sean Forbes Sean Forbes
https://dx.doi.org/10.21228/M8259N
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000456 AN000457
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 1290 Infinity Agilent 1290 Infinity
Column Thermo Hypercarb (50 x 2.1mm,3um) Waters Acquity HSS T3 (100 x 2.1mm,1.8um)
MS Type ESI ESI
MS instrument type Triple quadrupole Triple quadrupole
MS instrument name Agilent 6490 QQQ Agilent 6490 QQQ
Ion Mode POSITIVE POSITIVE
Units pmol/mg dry powder pmol/mg dry powder

Chromatography:

Chromatography ID:CH000325
Chromatography Summary:NAD-ATP method
Methods Filename:SB_NAD-ATP_Assay_Agilent.pdf
Instrument Name:Agilent 1290 Infinity
Column Name:Thermo Hypercarb (50 x 2.1mm,3um)
Chromatography Type:Reversed phase
  
Chromatography ID:CH000326
Chromatography Summary:NAD-ATP method
Methods Filename:SB_NADH_Assay_Agilent.pdf
Instrument Name:Agilent 1290 Infinity
Column Name:Waters Acquity HSS T3 (100 x 2.1mm,1.8um)
Column Temperature:30
Flow Rate:0.54 mL/min
Solvent A:100% water; 5 mM ammonium acetate, pH 6
Solvent B:100% acetonitrile
Chromatography Type:Reversed phase
  logo