Summary of Study ST000327

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000263. The data can be accessed directly via it's Project DOI: 10.21228/M8SK5S This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000327
Study TitlePrimary metabolites at different points along dog gastrointestinal tract (HILIC chromatography)
Study SummaryThis experiment tests the primary metabolites at four different points along the gastrointestinal tract of a dog. The four points being tested were the duodenum, ileum, colon, and rectum.
Institute
University of California, Davis
DepartmentGenome and Biomedical Sciences Facility
LaboratoryWCMC Metabolomics Core
Last NameFiehn
First NameOliver
Address1315 Genome and Biomedical Sciences Facility, 451 Health Sciences Drive, Davis, CA 95616
Emailofiehn@ucdavis.edu
Phone(530) 754-8258
Submit Date2015-02-27
Num Groups8
Total Subjects48
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2016-01-27
Release Version1
Oliver Fiehn Oliver Fiehn
https://dx.doi.org/10.21228/M8SK5S
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000521 AN000522
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Unspecified Unspecified
Column Waters Acquity BEH Amide (150 x 2.1mm,1.7um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6530 QTOF Agilent 6550 QTOF
Ion Mode POSITIVE NEGATIVE
Units Peak height Peak height

Chromatography:

Chromatography ID:CH000365
Chromatography Summary:UPLC
Methods Filename:Data_Dictionary_Fiehn_laboratory_HILIC_QTOF_MS.pdf
Instrument Name:Unspecified
Column Name:Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
Column Pressure:200-700 bar
Column Temperature:45 C
Flow Gradient:100% B to 30% B
Flow Rate:0.4 mL/min
Internal Standard:See data dictionary
Retention Time:See data dictionary
Sample Injection:3 uL
Analytical Time:14 min
Capillary Voltage:4500
Time Program:16.75 min
Weak Wash Solvent Name:1:1 ACN:H2O
Weak Wash Volume:5 seconds
Strong Wash Solvent Name:1:1 ACN:H2O
Target Sample Temperature:Autosampler temp 4 C
Randomization Order:Excel
Chromatography Type:HILIC