Summary of Study ST001807

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001141. The data can be accessed directly via it's Project DOI: 10.21228/M8711S This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001807
Study TitleUntargeted metabolomics of Daphnia magna exposed to a lithium cobalt oxide nanomaterial
Study TypeUntargeted MS
Study SummaryThe goal of this project was to determine lithium cobalt oxide (LCO)’s effects on pathways in the model organism Daphnia magna through untargeted metabolomics.
Institute
University of Wisconsin - Milwaukee
DepartmentSchool of Freshwater Sciences
LaboratoryRebecca Klaper
Last NameKlaper
First NameRebecca
Address600 E Greenfield Ave, Milwaukee, WI 53204
Emailrklaper@uwm.edu
Phone4143821713
Submit Date2021-05-18
Num Groups4
Total Subjects36
Study CommentsPooled samples of 20 Daphnia magna per replicate.
Raw Data AvailableYes
Raw Data File Type(s)mzXML
Analysis Type DetailMS(Dir. Inf.)
Release Date2022-05-19
Release Version1
Rebecca Klaper Rebecca Klaper
https://dx.doi.org/10.21228/M8711S
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002929 AN002930
Analysis type MS MS
Chromatography type None (Direct infusion) None (Direct infusion)
Chromatography system LTQ Orbitrap Elite (Thermo Fisher Scientific) LTQ Orbitrap Elite (Thermo Fisher Scientific)
Column none none
MS Type ESI ESI
MS instrument type LTQ-FT LTQ-FT
MS instrument name Thermo Orbitrap Elite Hybrid Ion Trap-Orbitrap Thermo Orbitrap Elite Hybrid Ion Trap-Orbitrap
Ion Mode POSITIVE NEGATIVE
Units arbitrary units arbitrary units

Chromatography:

Chromatography ID:CH002171
Chromatography Summary:Non-targeted analysis was carried out on polar fractions by direct infusion mass spectrometry (DIMS) using an LTQ Orbitrap Elite (Thermo Fisher Scientific). 21 overlapping selected ion monitoring (SIM) windows were collected covering m/z values from 50 to 620.
Instrument Name:LTQ Orbitrap Elite (Thermo Fisher Scientific)
Column Name:none
Chromatography Type:None (Direct infusion)
  logo