Summary of Study ST001807
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001141. The data can be accessed directly via it's Project DOI: 10.21228/M8711S This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001807 |
Study Title | Untargeted metabolomics of Daphnia magna exposed to a lithium cobalt oxide nanomaterial |
Study Type | Untargeted MS |
Study Summary | The goal of this project was to determine lithium cobalt oxide (LCO)’s effects on pathways in the model organism Daphnia magna through untargeted metabolomics. |
Institute | University of Wisconsin - Milwaukee |
Department | School of Freshwater Sciences |
Laboratory | Rebecca Klaper |
Last Name | Klaper |
First Name | Rebecca |
Address | 600 E Greenfield Ave, Milwaukee, WI 53204 |
rklaper@uwm.edu | |
Phone | 4143821713 |
Submit Date | 2021-05-18 |
Num Groups | 4 |
Total Subjects | 36 |
Study Comments | Pooled samples of 20 Daphnia magna per replicate. |
Raw Data Available | Yes |
Raw Data File Type(s) | mzXML |
Analysis Type Detail | MS(Dir. Inf.) |
Release Date | 2022-05-19 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002929 | AN002930 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | None (Direct infusion) | None (Direct infusion) |
Chromatography system | LTQ Orbitrap Elite (Thermo Fisher Scientific) | LTQ Orbitrap Elite (Thermo Fisher Scientific) |
Column | none | none |
MS Type | ESI | ESI |
MS instrument type | LTQ-FT | LTQ-FT |
MS instrument name | Thermo Orbitrap Elite Hybrid Ion Trap-Orbitrap | Thermo Orbitrap Elite Hybrid Ion Trap-Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | arbitrary units | arbitrary units |
Chromatography:
Chromatography ID: | CH002171 |
Chromatography Summary: | Non-targeted analysis was carried out on polar fractions by direct infusion mass spectrometry (DIMS) using an LTQ Orbitrap Elite (Thermo Fisher Scientific). 21 overlapping selected ion monitoring (SIM) windows were collected covering m/z values from 50 to 620. |
Instrument Name: | LTQ Orbitrap Elite (Thermo Fisher Scientific) |
Column Name: | none |
Chromatography Type: | None (Direct infusion) |