Summary of Study ST003315

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR002062. The data can be accessed directly via it's Project DOI: 10.21228/M82Z4P This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003315
Study TitleRandomized phase II trial of pre-operative fulvestrant with or without enzalutamide for ER+/Her2- primary breast cancer: effects on tumor immune microenvironment and clinical outcomes.
Study SummaryThis randomized phase II trial of 4 months of neoadjuvant fulvestrant (Fulv) alone or with enzalutamide (Combo) assessed whether the addition of AR blockade to Fulv would limit residual tumor at time of surgery, as measured by modified preoperative endocrine predictive index (PEPI) score. Eligible patients were women with ER+/HER2- primary BC cT2 or greater. Lithium-heparin (LiHep) plasma samples were obtained every 4 weeks until surgery and one month after surgery then analyzed by MS-based metabolomics.
Institute
University of Colorado Anschutz Medical Campus
Last NameHaines
First NameJulie
Address12801 E 17th Ave, Room 1303, Aurora, Colorado, 80045, USA
Emailjulie.haines@cuanschutz.edu
Phone3037243339
Submit Date2024-06-28
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-08-01
Release Version1
Julie Haines Julie Haines
https://dx.doi.org/10.21228/M82Z4P
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005428 AN005429
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) Phenomenex Kinetex C18 (150 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Orbitrap Exploris 120 Thermo Orbitrap Exploris 120
Ion Mode NEGATIVE POSITIVE
Units peak area peak area

Chromatography:

Chromatography ID:CH004117
Chromatography Summary:Negative C18
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (150 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:0-0.5 min 0% B, 0.5-1.1 min 0-100% B, 1.1-2.75 min hold at 100% B, 2.75-3 min 100-0% B, 3-5 min hold at 0% B
Flow Rate:450 uL/min
Sample Injection:10 uL
Solvent A:95% water/5% acetonitrile; 1 mM ammonium acetate
Solvent B:95% acetonitrile/5% water; 1 mM ammonium acetate
Chromatography Type:Reversed phase
  
Chromatography ID:CH004118
Chromatography Summary:Positive C18
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (150 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:0-0.5 min 5% B, 0.5-1.1 min 5-95% B, 1.1-2.75 min hold at 95% B, 2.75-3 min 95-5% B, 3-5 min hold at 5% B
Flow Rate:450 uL/min
Sample Injection:10 uL
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:Reversed phase
  logo