Summary of Study ST004390

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR002783. The data can be accessed directly via it's Project DOI: 10.21228/M8XK1H This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST004390
Study TitlePolar metabolites profiling between Human Fragile X Syndrome (FXS) and typically developing (TD) human cortex.
Study Summary​​Human but not mouse brain shows Fragile X mental retardation protein (FMRP)-dependent metabolic changes. Therefore, polar metabolomics were performed to compare human cortex from patients with and without Fragile X Syndrome. Many metabolic changes relate to glutamine and glutamate metabolism.
Institute
UMass Chan Medical School
Last NameUMass Chan
First NameRichter Lab
Address55 Lake Avenue North, Worcester, Massachusetts, 01605, USA
Emailspinellilab@gmail.com
Phone(508) 856-8989 ext. 68148
Submit Date2025-11-12
Raw Data AvailableYes
Raw Data File Type(s)mzML, raw(Thermo)
Analysis Type DetailLC-MS
Release Date2025-12-02
Release Version1
Richter Lab UMass Chan Richter Lab UMass Chan
https://dx.doi.org/10.21228/M8XK1H
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN007335 AN007336
Chromatography ID CH005566 CH005566
MS ID MS007029 MS007030
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Vanquish Thermo Vanquish
Column Merck SeQuant ZIC-HILIC (150 x 2.1mm,5um) Merck SeQuant ZIC-HILIC (150 x 2.1mm,5um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Peak Area Peak Area

Chromatography:

Chromatography ID:CH005566
Instrument Name:Thermo Vanquish
Column Name:Merck SeQuant ZIC-HILIC (150 x 2.1mm,5um)
Column Temperature:25
Flow Gradient:20 min, 80% - 20% B; 0.5 min, 20% - 80% B; 7.5min, 80% B
Flow Rate:0.15ml/min
Solvent A:100% water; 0.1% ammonium hydroxide; 20mM ammonium carbonate
Solvent B:100% acetonitrile
Chromatography Type:HILIC