Summary of Study ST000237

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000190. The data can be accessed directly via it's Project DOI: 10.21228/M8Q30F This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Show all samples  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files
Study IDST000237
Study TitleQuick Comparison of Serum Metabolites in SD Rats of Different Sex by Untargeted UPLC-TOFMS and In-house Software Platform
Study TypeBiomarker Discovery
Study SummaryMale (n=8) and female (n=8) SD rats weighing between 220 and 250g were used. On the morning of sample collection day, each rat was deprived of food and put in metabolic cage for 24h urine collection. Then a blood sample (3-5ml) was collected from the aorta of the rat under anesthesia and centrifuged to obtain serum. All urine and serum samples were frozen at -80°C prior to analysis.
Institute
Beijing Institute of Radiation Medicine
DepartmentDepartment of Pharmacology and Toxicology
Last NameLiang
First NameQiande
Address27 Taiping Road, Beijing, P.R.China
Emailliangqiande@yeah.net
Submit Date2015-08-09
Num Groups2
Total Subjects16
Raw Data File Type(s)raw(Waters)
Analysis Type DetailLC-MS
Release Date2015-09-09
Release Version1
Qiande Liang Qiande Liang
https://dx.doi.org/10.21228/M8Q30F
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000363 AN000364
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Waters Acquity Waters Acquity
Column Waters Acquity HSS T3 (100 x 2.1mm,1.8um) Waters Acquity HSS T3 (100 x 2.1mm,1.8um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Waters Synapt-HDMS Waters Synapt-HDMS
Ion Mode POSITIVE NEGATIVE
Units Peak Height Peak Height

MS:

MS ID:MS000309
Analysis ID:AN000363
Instrument Name:Waters Synapt-HDMS
Instrument Type:QTOF
MS Type:ESI
Ion Mode:POSITIVE
Capillary Voltage:3kV
Collision Energy:6V (trap)/4V (transfer)
Collision Gas:Ar
Dry Gas Flow:900 L/h
Dry Gas Temp:450?
Ion Source Temperature:100?
Ionization:ESI
Source Temperature:100?
Desolvation Gas Flow:900 L/h
Desolvation Temperature:450?
Acquisition Parameters File:Inlet_Method_File_Name:_20100505
_Positive_MS_Mehod_File_Name:_20120221_pos_50-1500
Processing Parameters File:TR_0-18_50-1500_005_020_YES6_YES.mlm
  
MS ID:MS000310
Analysis ID:AN000364
Instrument Name:Waters Synapt-HDMS
Instrument Type:QTOF
MS Type:ESI
Ion Mode:NEGATIVE
Capillary Voltage:2.9kV
Collision Energy:6V (trap)/4V (transfer)
Collision Gas:Ar
Dry Gas Flow:900 L/h
Dry Gas Temp:450?
Ion Source Temperature:100?
Ionization:ESI
Source Temperature:100?
Desolvation Gas Flow:900 L/h
Desolvation Temperature:450?
Acquisition Parameters File:Negative_MS_Mehod_File_Name:_20120221_neg_50-1500
Processing Parameters File:TR_0-18_50-1500_005_020_YES6_YES.mlm
  logo