Summary of Study ST000655

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000461. The data can be accessed directly via it's Project DOI: 10.21228/M8G609 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files
Study IDST000655
Study TitleOmega-6 and omega-3 oxylipins are implicated in soybean oil-induced obesity in mice (part II)
Study SummaryIn this study we have compared the metabolic effects of conventional soybean oil to those of genetically modified Plenish soybean oil, that is low in linoleic acid and high in oleic acid. This work builds on our previous study showing that soybean oil, rich in polyunsaturated fats, is more obesogenic and diabetogenic than coconut oil, rich in saturated fats (PMID: 26200659). Here, in order to elucidate the mechanisms responsible for soybean oil induced obesity, we have performed the first ever metabolomics (in plasma and liver) and proteomics on the livers of mice fed the two soybean oil diets (plus those fed a high coconut oil and Viv chow diet). Our results show that the new high oleic soybean oil induces less obesity and adiposity than conventional soybean oil, but can cause hepatomegaly and liver dysfunction. Metabolomic analysis reveals that the hepatic and plasma metabolic profiles differ considerably between the two soybean oils. Hepatic C18 oxylipin metabolites of omega-6 (ω6) and omega-3 (ω3) fatty acids (linoleic and α-linolenic acid, respectively) in the cytochrome P450/soluble epoxide hydrolase pathway were found to correlate positively with obesity.
Institute
University of California, Davis
DepartmentGenome and Biomedical Sciences Facility
LaboratoryWCMC Metabolomics Core
Last NameFiehn
First NameOliver
Address1315 Genome and Biomedical Sciences Facility, 451 Health Sciences Drive, Davis, CA 95616
Emailofiehn@ucdavis.edu
Phone(530) 754-8258
Submit Date2017-06-22
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2017-07-01
Release Version1
Oliver Fiehn Oliver Fiehn
https://dx.doi.org/10.21228/M8G609
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000999 AN001000
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 6530 Agilent 6550
Column Waters Acquity CSH C18 (100 x 2.1mm,1.7um) Waters Acquity CSH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6530 QTOF Agilent 6550 QTOF
Ion Mode POSITIVE NEGATIVE
Units Counts Counts

MS:

MS ID:MS000894
Analysis ID:AN000999
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:POSITIVE
Capillary Voltage:3500 eV
Collision Energy:25 eV
Collision Gas:Nitrogen
Dry Gas Flow:8L/min
Dry Gas Temp:325 C
Fragment Voltage:120 eV
Fragmentation Method:Auto MS/MS
Ion Source Temperature:325 C
Ion Spray Voltage:1000
Ionization:Pos
Precursor Type:Intact Molecule
Reagent Gas:Nitrogen
Source Temperature:325 C
Dataformat:.d
Desolvation Gas Flow:11 L/min
Desolvation Temperature:350 C
Nebulizer:35 psig
Octpole Voltage:750
Resolution Setting:Exteded Dyamic Range
Scan Range Moverz:60-1700 Da
Scanning Cycle:2 Hz
Scanning Range:60-1700 Da
Skimmer Voltage:65
  
MS ID:MS000895
Analysis ID:AN001000
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:NEGATIVE
Capillary Voltage:3500 eV
Collision Energy:40 eV
Collision Gas:Nitrogen
Dry Gas Flow:13L/min
Dry Gas Temp:200 C
Fragment Voltage:175 eV
Fragmentation Method:Auto MS/MS
Ion Source Temperature:325 C
Ion Spray Voltage:1000
Ionization:Neg
Precursor Type:Intact Molecule
Reagent Gas:Nitrogen
Source Temperature:325 C
Dataformat:.d
Desolvation Gas Flow:11 L/min
Desolvation Temperature:350 C
Nebulizer:35 psig
Octpole Voltage:750
Resolution Setting:Exteded Dyamic Range
Scan Range Moverz:60-1700 Da
Scanning Cycle:2 Hz
Scanning Range:60-1700 Da
Skimmer Voltage:65
  logo