Summary of Study ST000742

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000535. The data can be accessed directly via it's Project DOI: 10.21228/M8HH47 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000742
Study TitleMetabolite-phenotype link in X-linked Adrenoleukodystrophy (part II)
Study TypeMS analysis
Study SummaryUntargeted metabolomics of control, AMN and ALD patient-derived fibroblasts. Human Postmortem brain tissue were obtained from NICHD Brain Bank. Brain regions were directed by the neuropathologist at Henry Ford Health System and sample tissue were immediately frozen at -80C until shipping to the UMICH Core.
Institute
University of Michigan
DepartmentBiomedical Research Core Facilities
LaboratoryMetabolomics core
Last NameKachman
First NameMaureen
Address6300 Brehm Tower, 1000 Wall Street, Ann Arbor, MI 48105-5714
Emailmkachman@med.umich.edu
Phone(734) 232-8175
Submit Date2017-06-19
Num Groups9
Total Subjects3
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2017-12-06
Release Version1
Maureen Kachman Maureen Kachman
https://dx.doi.org/10.21228/M8HH47
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001157 AN001158
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent Agilent
Column Waters Acquity HSS T3 (50 x 2.1mm,1.8um) Waters Acquity HSS T3 (50 x 2.1mm,1.8um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6530 QTOF Agilent 6530 QTOF
Ion Mode NEGATIVE POSITIVE
Units peak area normalized peak area normalized

MS:

MS ID:MS001052
Analysis ID:AN001157
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:NEGATIVE
Analysis Protocol File:A003_-_Untargeted_Metabolomics.pdf
  
MS ID:MS001053
Analysis ID:AN001158
Instrument Name:Agilent 6530 QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:POSITIVE
Analysis Protocol File:A003_-_Untargeted_Metabolomics.pdf
  logo