Summary of Study ST000770
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000556. The data can be accessed directly via it's Project DOI: 10.21228/M8ST09 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST000770 |
Study Title | Intranasal oxytocin in lean and obese men |
Study Type | MS analysis |
Study Summary | From Lawson et al., Obesity 2015 (PMID: 25865294). Methods: A randomized, placebo-controlled crossover study of single-dose intranasal oxytocin (24 IU) in 25 fasting healthy men was performed. After oxytocin/placebo, subjects selected breakfast from a menu and were given double portions. Caloric content of food consumed was measured. Visual analog scales were used to assess appetite, and blood was drawn for appetite-regulating hormones, insulin, and glucose before and after oxytocin/placebo. Indirect calorimetry assessed resting energy expenditure (REE) and substrate utilization. Here, T0 refers to immediately before OXT or Placebo was administered (fasting), and T55 refers to 55 minutes post-administration (fasting, immediately pre-meal). |
Institute | University of Michigan |
Department | Biomedical Research Core Facilities |
Laboratory | Metabolomics core |
Last Name | Kachman |
First Name | Maureen |
Address | 6300 Brehm Tower, 1000 Wall Street, Ann Arbor, MI 48105-5714 |
mkachman@med.umich.edu | |
Phone | (734) 232-8175 |
Submit Date | 2017-06-19 |
Num Groups | 8 |
Total Subjects | 25 |
Raw Data Available | Yes |
Raw Data File Type(s) | d |
Analysis Type Detail | LC-MS |
Release Date | 2017-12-06 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN001217 |
---|---|
Analysis type | MS |
Chromatography type | Reversed phase |
Chromatography system | Agilent |
Column | Waters Xbridge BEH C18 (50 x 1mm,3.5um) |
MS Type | ESI |
MS instrument type | Triple quadrupole |
MS instrument name | Agilent 6490A QQQ |
Ion Mode | POSITIVE |
Units | uM |
MS:
MS ID: | MS001112 |
Analysis ID: | AN001217 |
Instrument Name: | Agilent 6490A QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
Ion Mode: | POSITIVE |
Analysis Protocol File: | A008_-_Acyl_Carnitines.pdf |