Summary of Study ST000955

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000656. The data can be accessed directly via it's Project DOI: 10.21228/M8W39D This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000955
Study TitleEffects of ODC inhibition on T cell metabolism
Study Typedrug treatment at two time
Study SummaryIsolated T cells were activated for 48-72 hours in the presence and absence of 5mM DFMO, an ODC inhibitor
Institute
University of Florida
DepartmentSECIM
Last NameHesterberg
First NameRebecca
Address12902 Magnolia Dr
Emailrebecca.hesterberg@moffitt.org
Phone813-270-9181
Submit Date2018-04-14
Num Groups4
Total Subjects16
Study CommentsOT-1 mice express a transgenic T cell receptor in all CD8+ T cells that binds with high affinity to a peptide derived from the protein ovalbumin (SIINFEKL).
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2019-05-15
Release Version1
Rebecca Hesterberg Rebecca Hesterberg
https://dx.doi.org/10.21228/M8W39D
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001566 AN001567
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column ACE Excel 2 C18-PFP (100 x 2.1mm, 2um) ACE Excel 2 C18-PFP (100 x 2.1mm, 2um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak height peak height

MS:

MS ID:MS001444
Analysis ID:AN001566
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
Ion Mode:POSITIVE
  
MS ID:MS001445
Analysis ID:AN001567
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
Ion Mode:NEGATIVE
  logo