Summary of Study ST001651

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001057. The data can be accessed directly via it's Project DOI: 10.21228/M82Q48 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001651
Study TitleAnalysis of metabolites in gut microbioal culture media and microbial cells
Study SummaryWe developed an untargeted stable isotope-resolved metabolomics (SIRM) approach for the holistic study of gut microbial metabolites
Institute
University of Kentucky
Last NameDeng
First NamePan
Address789 South Limestone
Emailpde233@uky.edu
Phone8595623039
Submit Date2020-12-11
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2021-03-01
Release Version1
Pan Deng Pan Deng
https://dx.doi.org/10.21228/M82Q48
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002697 AN002698
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column SeQuant ZIC-HILIC (150 x 2.1mm,5um) SeQuant ZIC-HILIC (150 x 2.1mm,5um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak area peak area

MS:

MS ID:MS002495
Analysis ID:AN002697
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The mass spectrometer was operated in positive and negative ionization modes. Initial metabolite identification was performed using Compound Discoverer 3.1 (Thermo Fisher Scientific).Metabolites were further confirmed by comparison of the ion features in the samples with an in-house reference library of authentic chemical standards. Peak areas of metabolites and isotopologues were integrated and exported to Excel via the TraceFinder 5.0 software package (Thermo Fisher Scientific).
Ion Mode:POSITIVE
  
MS ID:MS002496
Analysis ID:AN002698
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The mass spectrometer was operated in positive and negative ionization modes. Initial metabolite identification was performed using Compound Discoverer 3.1 (Thermo Fisher Scientific).Metabolites were further confirmed by comparison of the ion features in the samples with an in-house reference library of authentic chemical standards. Peak areas of metabolites and isotopologues were integrated and exported to Excel via the TraceFinder 5.0 software package (Thermo Fisher Scientific).
Ion Mode:NEGATIVE
  logo