Summary of Study ST001686

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001084. The data can be accessed directly via it's Project DOI: 10.21228/M8KH57 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001686
Study TitleExposure to per- and polyfluoroalkyl substances associates with altered lipid profile of breast milk (Part 3)
Study SummaryIn this mother-infant study (n=44) we investigated the levels of PFAS in maternal serum and detailed lipidomic profile in breast milk at birth and at three months using ultra high performance liquid chromatography combined with quadrupole-time-of-flight mass spectrometry.
Institute
University of Turku
Last NameLamichhane
First NameSantosh
AddressTykistökatu 6, FI-20520 Turku, Finland
Emailsantosh.lamichhane@utu.fi
Phone0452299070
Submit Date2021-02-08
Raw Data AvailableYes
Raw Data File Type(s)mzdata.xml
Analysis Type DetailLC-MS
Release Date2021-10-02
Release Version1
Santosh Lamichhane Santosh Lamichhane
https://dx.doi.org/10.21228/M8KH57
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002753
Analysis type MS
Chromatography type Reversed phase
Chromatography system Waters Acquity UPLC
Column BEH C18
MS Type ESI
MS instrument type QTOF
MS instrument name Agilent 6210 TOF
Ion Mode NEGATIVE
Units ng/ml

MS:

MS ID:MS002550
Analysis ID:AN002753
Instrument Name:Agilent 6210 TOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Dual jet stream electrospray (dual ESI) ion source was used and the ion polarity was on negative mode. The capillary voltage and the nozzle voltage were kept at 4500 V and 1500 V. The N2 pressure was set on 21 psi, with the sheath gas flow as 11 L/min and temperature at 379°C for the nebulizer. The data was acquired with MassHunter B.06.01 software (Agilent Technologies, Santa Clara, CA, The United States of America).
Ion Mode:NEGATIVE