This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001104. The data can be accessed directly via it's Project DOI: 10.21228/M80M6C This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001723
Study TitleThe effects of birth weight and breeding value for protein deposition on the plasma metabolome in growing pigs (part-II)
Study SummaryAn experiment was conducted with growing pigs, to determine the effects of birth weight (BiW) and estimated breeding value for protein deposition (EBV) on the metabolomic profile in plasma samples collected under different dietary regimens: protein adequate (A) or protein restricted (R, 70% of A).
Institute
Aarhus University
DepartmentAnimal Science
LaboratoryMetabolomics LC-MS platform Aarhus University Foulum
Last NameHedemann
First NameMette
AddressBlichers Alle 20, Tjele, -, 8830, Denmark
EmailMette.Hedemann@anis.au.dk
Phone51448783
Submit Date2021-03-14
Total Subjects40
Num Males40
Raw Data AvailableYes
Raw Data File Type(s)mzXML
Analysis Type DetailLC-MS
Release Date2021-03-31
Release Version1
Mette Hedemann Mette Hedemann
https://dx.doi.org/10.21228/M80M6C
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002807
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 RS
Column Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um)
MS Type ESI
MS instrument type QTOF
MS instrument name Bruker Impact HD
Ion Mode POSITIVE
Units peak area

MS:

MS ID:MS002602
Analysis ID:AN002807
Instrument Name:Bruker Impact HD
Instrument Type:QTOF
MS Type:ESI
MS Comments:The eluent was introduced into the mass spectrometer by electrospray ionization, with capillary set in the positive and negative mode to 4500 and 3600 V, respectively. End-plate offset voltage was set to 500 V. Nitrogen was used as both nebulizer and drying gas with a gas pressure of 1.8 bar. Drying gas temperature and flow were 200 °C and 8.0 L/min, respectively. Spectra were acquired over the scan range of 50−1000 m/z. A solution of lithium formate clusters (5 mM) (water/isopropanol/formic acid in a 50:50:0.2 v/v/v ratio) was injected prior to each chromatographic run as an external calibrant.
Ion Mode:POSITIVE