Summary of Study ST003065

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001911. The data can be accessed directly via it's Project DOI: 10.21228/M8Q148 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST003065
Study TitleInvestigative needle core biopsies for multi-omics in Glioblastoma
Study SummaryGlioblastoma (GBM) is a primary brain cancer with an abysmal prognosis and few effective therapies. The ability to investigate the tumor microenvironment before and during treatment would greatly enhance both our understanding of disease response and progression, as well as the delivery and impact of therapeutics. Stereotactic biopsies are a routine surgical procedure performed primarily for diagnostic histopathologic purposes. The role of investigative biopsies – tissue sampling for the purpose of understanding tumor microenvironmental responses to treatment using integrated multi-modal molecular analyses (‘Multi-omics”) has yet to be defined. Here we adapt stereotactic needle core biopsy tissue for highly resolved multi-omics analysis methods including single cell RNA sequencing, spatial-transcriptomics, metabolomics, proteomics, phosphoproteomics, T-cell clonotype analysis, and MHC Class I immunopeptidomics. Biopsy tissue was obtained from a single patient with recurrent GBM during one procedure. In a second patient, we analyzed multi-regional core biopsies to decipher spatial and genomic variance. Finally in a separate cohort of patients we investigated the utility of stereotactic biopsies as a method for generating patient derived xenograft models. Dataset integration across modalities showed good correspondence between spatial modalities and highlighted immune cell associated metabolic pathways and poor correlation between RNA expression and the tumor MHC Class I immunopeptidome. In conclusion, stereotactic needle biopsy cores are of sufficient quality for the purposes of investigative biopsy and can generate multi-omics data, providing data rich insight into a patient’s disease process and tumor immune microenvironment and could be of potential value in evaluating treatment responses.
Institute
Brigham and Women's Hospital
DepartmentDepartment of Neurosurgery
LaboratoryNathalie Y.R. Agar
Last NameStopka
First NameSylwia
Address60 Fenwood Rd
Emailsstopka@bwh.harvard.edu
Phone617-525-9746
Submit Date2024-02-01
Raw Data AvailableYes
Raw Data File Type(s)imzML
Analysis Type DetailMALDI
Release Date2025-02-03
Release Version1
Sylwia Stopka Sylwia Stopka
https://dx.doi.org/10.21228/M8Q148
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN005021
Analysis type MS
Chromatography type None (Direct infusion)
Chromatography system none
Column none
MS Type MALDI
MS instrument type FT-ICR
MS instrument name Bruker Solarix FT-ICR-MS
Ion Mode NEGATIVE
Units Total Ion Count

MS:

MS ID:MS004760
Analysis ID:AN005021
Instrument Name:Bruker Solarix FT-ICR-MS
Instrument Type:FT-ICR
MS Type:MALDI
MS Comments:Bruker software
Ion Mode:NEGATIVE