Summary of Study ST004390
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR002783. The data can be accessed directly via it's Project DOI: 10.21228/M8XK1H This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
| Study ID | ST004390 |
| Study Title | Polar metabolites profiling between Human Fragile X Syndrome (FXS) and typically developing (TD) human cortex. |
| Study Summary | Human but not mouse brain shows Fragile X mental retardation protein (FMRP)-dependent metabolic changes. Therefore, polar metabolomics were performed to compare human cortex from patients with and without Fragile X Syndrome. Many metabolic changes relate to glutamine and glutamate metabolism. |
| Institute | UMass Chan Medical School |
| Last Name | UMass Chan |
| First Name | Richter Lab |
| Address | 55 Lake Avenue North, Worcester, Massachusetts, 01605, USA |
| spinellilab@gmail.com | |
| Phone | (508) 856-8989 ext. 68148 |
| Submit Date | 2025-11-12 |
| Raw Data Available | Yes |
| Raw Data File Type(s) | mzML, raw(Thermo) |
| Analysis Type Detail | LC-MS |
| Release Date | 2025-12-02 |
| Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
| Analysis ID | AN007335 | AN007336 |
|---|---|---|
| Chromatography ID | CH005566 | CH005566 |
| MS ID | MS007029 | MS007030 |
| Analysis type | MS | MS |
| Chromatography type | HILIC | HILIC |
| Chromatography system | Thermo Vanquish | Thermo Vanquish |
| Column | Merck SeQuant ZIC-HILIC (150 x 2.1mm,5um) | Merck SeQuant ZIC-HILIC (150 x 2.1mm,5um) |
| MS Type | ESI | ESI |
| MS instrument type | Orbitrap | Orbitrap |
| MS instrument name | Thermo Q Exactive Plus Orbitrap | Thermo Q Exactive Plus Orbitrap |
| Ion Mode | POSITIVE | NEGATIVE |
| Units | Peak Area | Peak Area |
MS:
| MS ID: | MS007029 |
| Analysis ID: | AN007335 |
| Instrument Name: | Thermo Q Exactive Plus Orbitrap |
| Instrument Type: | Orbitrap |
| MS Type: | ESI |
| MS Comments: | The mass spectrometer was set to full scan (70-1000 m/z), with the spray voltage set to 4.0 kV, heated capillary to 350°C, and the HESI probe at 30 °C. The sheath gas flow was set at 10 units, auxiliary gas at 1 units, and sweep gas flow at 1 unit. The resolution of scan was set to 70,000, AGC target to 1x106, and maximum injection time at 20 msec. Data acquired by Thermo Fisher's Xcalibur software and analyzed by their Tracefinder software. The raw files provided contain data from both positive and negative ion mode. |
| Ion Mode: | POSITIVE |
| MS ID: | MS007030 |
| Analysis ID: | AN007336 |
| Instrument Name: | Thermo Q Exactive Plus Orbitrap |
| Instrument Type: | Orbitrap |
| MS Type: | ESI |
| MS Comments: | The mass spectrometer had the spray voltage set to 4.0 kV, heated capillary to 350°C, and the HESI probe at 30 °C. The sheath gas flow was set at 10 units, auxiliary gas at 1 units, and sweep gas flow at 1 unit. An additional scan between 220-700 m/z was used to enhance nucleotide detection in the negative mode as well with the maximum injection time set to 80 msec. Data acquired by Thermo Fisher's Xcalibur software and analyzed by their Tracefinder software. The raw files provided contain data from both positive and negative ion mode. |
| Ion Mode: | NEGATIVE |