Summary of Study ST004390

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR002783. The data can be accessed directly via it's Project DOI: 10.21228/M8XK1H This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST004390
Study TitlePolar metabolites profiling between Human Fragile X Syndrome (FXS) and typically developing (TD) human cortex.
Study Summary​​Human but not mouse brain shows Fragile X mental retardation protein (FMRP)-dependent metabolic changes. Therefore, polar metabolomics were performed to compare human cortex from patients with and without Fragile X Syndrome. Many metabolic changes relate to glutamine and glutamate metabolism.
Institute
UMass Chan Medical School
Last NameUMass Chan
First NameRichter Lab
Address55 Lake Avenue North, Worcester, Massachusetts, 01605, USA
Emailspinellilab@gmail.com
Phone(508) 856-8989 ext. 68148
Submit Date2025-11-12
Raw Data AvailableYes
Raw Data File Type(s)mzML, raw(Thermo)
Analysis Type DetailLC-MS
Release Date2025-12-02
Release Version1
Richter Lab UMass Chan Richter Lab UMass Chan
https://dx.doi.org/10.21228/M8XK1H
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN007335 AN007336
Chromatography ID CH005566 CH005566
MS ID MS007029 MS007030
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system Thermo Vanquish Thermo Vanquish
Column Merck SeQuant ZIC-HILIC (150 x 2.1mm,5um) Merck SeQuant ZIC-HILIC (150 x 2.1mm,5um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap Thermo Q Exactive Plus Orbitrap
Ion Mode POSITIVE NEGATIVE
Units Peak Area Peak Area

MS:

MS ID:MS007029
Analysis ID:AN007335
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The mass spectrometer was set to full scan (70-1000 m/z), with the spray voltage set to 4.0 kV, heated capillary to 350°C, and the HESI probe at 30 °C. The sheath gas flow was set at 10 units, auxiliary gas at 1 units, and sweep gas flow at 1 unit. The resolution of scan was set to 70,000, AGC target to 1x106, and maximum injection time at 20 msec. Data acquired by Thermo Fisher's Xcalibur software and analyzed by their Tracefinder software. The raw files provided contain data from both positive and negative ion mode.
Ion Mode:POSITIVE
  
MS ID:MS007030
Analysis ID:AN007336
Instrument Name:Thermo Q Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The mass spectrometer had the spray voltage set to 4.0 kV, heated capillary to 350°C, and the HESI probe at 30 °C. The sheath gas flow was set at 10 units, auxiliary gas at 1 units, and sweep gas flow at 1 unit. An additional scan between 220-700 m/z was used to enhance nucleotide detection in the negative mode as well with the maximum injection time set to 80 msec. Data acquired by Thermo Fisher's Xcalibur software and analyzed by their Tracefinder software. The raw files provided contain data from both positive and negative ion mode.
Ion Mode:NEGATIVE