Summary of Study ST000134

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000119. The data can be accessed directly via it's Project DOI: 10.21228/M86C76 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files
Study IDST000134
Study TitleMonitoring In Vitro Response of Selenium-Treated Prostate Cells by 1H NMR Spectroscopy
Study TypeMetabolite level response after treatment with organoselenium
Study SummaryMetabolomics analysis was performed on DU145 prostate cancer cells and PNT1A non-tumorigenic prostate cells after treatment with selenomethionine and Se-methylselenocysteine using 800 MHz Bruker NMR spectrometer on 18 cell samples.
Institute
Purdue University
DepartmentBiology/Chemistry
LaboratoryBiology/Chemistry
Last NameIsaac-Lam
First NameMeden
Address1401 S US Hwy 421, Westville, IN 46391
Emailisaaclam@pnc.edu
Phone219-785-5776
Submit Date2015-01-13
Num Groups6
Total Subjects18
Raw Data AvailableNo
Analysis Type DetailNMR
Release Date2015-01-13
Release Version1
Meden Isaac-Lam Meden Isaac-Lam
https://dx.doi.org/10.21228/M86C76
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


NMR:

NMR ID:NM000050
Analysis ID:AN000216
Instrument Name:Bruker Avance III
Instrument Type:FT-NMR
NMR Experiment Type:1D 1H
Field Frequency Lock:Deuterium
Standard Concentration:1.43 mM
Spectrometer Frequency:800 MHz
NMR Probe:TX1, inverse
NMR Solvent:D2O
NMR Tube Size:5 mm x 7 in
Shimming Method:gradient, topshim
Pulse Sequence:zg one-pulse
Water Suppression:presaturation
Pulse Width:8.5 msec
Power Level:12.25 W
Receiver Gain:912
Offset Frequency:4.8 ppm
Presaturation Power Level:57 dB
Chemical Shift Ref Cpd:TMSP
Temperature:295.9
Number Of Scans:256
Dummy Scans:8
Acquisition Time:1.4680564
Relaxation Delay:6.5 msec
Spectral Width:11160 Hz
Num Data Points Acquired:32 K
Real Data Points:32 K
Line Broadening:1 Hz
Zero Filling:16K
Apodization:lorentzian
Baseline Correction Method:polynomial
Chemical Shift Ref Std:TMSP