MoNA MS database records for trans-zeatin
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
BML82270 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | positive | MS1 |
BML82271 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | - | - | negative | MS1 |
BML82272 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | positive | MS1 |
BML82273 | Agilent 1200 RRLC; Agilent 652... | LC-APCI-QTOF | - | - | - | negative | MS1 |
BML00864 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M+H]+ | positive | MS2 |
BML00873 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M+H]+ | positive | MS2 |
BML00882 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M+H]+ | positive | MS2 |
BML00890 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 10 ev | [M-H]- | negative | MS2 |
BML00895 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 20 ev | [M-H]- | negative | MS2 |
BML00900 | Agilent 1200 RRLC; Agilent 652... | LC-ESI-QTOF | - | 40 ev | [M-H]- | negative | MS2 |
CE000580 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 47.0eV | [M+H]+ | positive | MS2 |
KO002018 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
KO002019 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
KO002020 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
KO002021 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
KO002022 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
KO004276 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO004277 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO004278 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO004279 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO004280 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
KO009317 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.7 | [M+H]+ | positive | MS2 |
ML005601 | LTQ Orbitrap Velos Thermo Scie... | LC-ESI-ITFT | ESI | 50 % (nominal) | [M+H]+ | positive | MS2 |
NA000868 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 10 % (nominal) | [M+H]+ | positive | MS2 |
NA000869 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
NA000870 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 20 % (nominal) | [M+H]+ | positive | MS2 |
NA000871 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 25 % (nominal) | [M+H]+ | positive | MS2 |
NA000872 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
NA000993 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 15 % (nominal) | [M+H]+ | positive | MS2 |
NA000994 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 20 % (nominal) | [M+H]+ | positive | MS2 |
NA000995 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 25 % (nominal) | [M+H]+ | positive | MS2 |
NA000996 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 30 % (nominal) | [M+H]+ | positive | MS2 |
NA000997 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
NA001122 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 40 % (nominal) | [M+H]+ | positive | MS2 |
NA001123 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 35 % (nominal) | [M+H]+ | positive | MS2 |
NA001124 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 50 % (nominal) | [M+H]+ | positive | MS2 |
NA001125 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
NA001126 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 60 % (nominal) | [M+H]+ | positive | MS2 |
NA001244 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 45 % (nominal) | [M+H]+ | positive | MS2 |
NA001245 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 40 % (nominal) | [M+H]+ | positive | MS2 |
NA001246 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 % (nominal) | [M+H]+ | positive | MS2 |
NA001247 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 50 % (nominal) | [M+H]+ | positive | MS2 |
NA001248 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 65 % (nominal) | [M+H]+ | positive | MS2 |
NA001374 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 70 % (nominal) | [M+H]+ | positive | MS2 |
NA001375 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 % (nominal) | [M+H]+ | positive | MS2 |
NA001376 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 % (nominal) | [M+H]+ | positive | MS2 |
NA001377 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 65 % (nominal) | [M+H]+ | positive | MS2 |
NA001378 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
NA001499 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 70 % (nominal) | [M+H]+ | positive | MS2 |
NA001500 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 55 % (nominal) | [M+H]+ | positive | MS2 |
NA001501 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 % (nominal) | [M+H]+ | positive | MS2 |
NA001502 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 65 % (nominal) | [M+H]+ | positive | MS2 |
NA001503 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
NA001754 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 100 % (nominal) | [M+H]+ | positive | MS2 |
NA001755 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 75 % (nominal) | [M+H]+ | positive | MS2 |
NA001756 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 110 % (nominal) | [M+H]+ | positive | MS2 |
NA001757 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 85 % (nominal) | [M+H]+ | positive | MS2 |
NA001758 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 120 % (nominal) | [M+H]+ | positive | MS2 |
NA001881 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 105 % (nominal) | [M+H]+ | positive | MS2 |
NA001882 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 % (nominal) | [M+H]+ | positive | MS2 |
NA001883 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 115 % (nominal) | [M+H]+ | positive | MS2 |
NA001884 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
NA001885 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 125 % (nominal) | [M+H]+ | positive | MS2 |
NA001999 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 105 % (nominal) | [M+H]+ | positive | MS2 |
NA002000 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 % (nominal) | [M+H]+ | positive | MS2 |
NA002001 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 115 % (nominal) | [M+H]+ | positive | MS2 |
NA002002 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
NA002003 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 125 % (nominal) | [M+H]+ | positive | MS2 |
NA002110 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 105 % (nominal) | [M+H]+ | positive | MS2 |
NA002111 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 80 % (nominal) | [M+H]+ | positive | MS2 |
NA002112 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 115 % (nominal) | [M+H]+ | positive | MS2 |
NA002113 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 90 % (nominal) | [M+H]+ | positive | MS2 |
NA002114 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | ESI | 125 % (nominal) | [M+H]+ | positive | MS2 |
PR020086 | UPLC Waters, Quattro Ultima Pt... | LC-ESI-QQ | ESI | 10.0 eV | [M+H]+ | positive | MS2 |
PR020087 | UPLC Waters, Quattro Ultima Pt... | LC-ESI-QQ | ESI | 20.0 eV | [M+H]+ | positive | MS2 |
PR020088 | UPLC Waters, Quattro Ultima Pt... | LC-ESI-QQ | ESI | 30.0 eV | [M+H]+ | positive | MS2 |
PR100323 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M+H]+ | positive | MS2 |
PR100759 | UPLC Q-Tof Premier, Waters | LC-ESI-QTOF | ESI | Ramp 5-60 V | [M-H]- | negative | MS2 |
PS073101 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS073102 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS073103 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS073104 | TQD, Waters | Flow-injection QqQ/MS | ESI | 40 | [M+H]+ | positive | MS2 |
PS073107 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M-H]- | negative | MS2 |
PT107310 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M+H]+ | positive | MS2 |
PT207310 | Q-Tof Premier, Waters | LC-Q-TOF/MS | ESI | Ramp 5-45 V | [M-H]- | negative | MS2 |
VF-NPL-LTQ000295 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-QEHF000628 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000629 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000630 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000631 | Thermo Q Exactive HF | ESI-QFT | - | 25HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000632 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000633 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002132 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002133 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002134 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF002135 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002136 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF002137 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF005107 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF005108 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF005109 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF005110 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF005111 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF005112 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF005113 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF005114 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF005115 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009983 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF009984 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF009985 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Cl]- | negative | MS2 |
VF-NPL-QTOF009986 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+FA-H]- | negative | MS2 |
VF-NPL-QTOF009987 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+FA-H]- | negative | MS2 |
VF-NPL-QTOF009988 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+FA-H]- | negative | MS2 |
VF-NPL-QTOF009989 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF009990 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF009991 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+Na]+ | positive | MS2 |
VF-NPL-QTOF009992 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009993 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009994 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF009995 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009996 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF009997 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000298 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
VF-NPL-LTQ000296 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
KO009318 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.70/0.70 | [M+H]+ | positive | MS3 |
KO009319 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.70/0.70 | [M+H]+ | positive | MS3 |
KO009320 | LC/MSD Trap XCT, Agilent Techn... | LC-ESI-IT | - | 0.70/0.60 | [M+H]+ | positive | MS3 |
HMDB0012204_c_ms_2079 | LC/MSD Trap XCT, Agilent Techn... | GC-MS | - | - | - | - | - |