Massbank MS database records for Dronedarone
| Massbank ID | Instrument | Inst. type | Collision energy | Ion type | Ion mode | MS level |
|---|---|---|---|---|---|---|
| MSBNK-Athens_Univ-AU218101 | Bruker maXis Impact | LC-ESI-QTOF | 10 eV | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218102 | Bruker maXis Impact | LC-ESI-QTOF | 20 eV | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218103 | Bruker maXis Impact | LC-ESI-QTOF | 30 eV | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218104 | Bruker maXis Impact | LC-ESI-QTOF | 40 eV | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218105 | Bruker maXis Impact | LC-ESI-QTOF | 50 eV | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218107 | Bruker maXis Impact | LC-ESI-QTOF | 10 eV | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218108 | Bruker maXis Impact | LC-ESI-QTOF | 20 eV | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218109 | Bruker maXis Impact | LC-ESI-QTOF | 30 eV | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218110 | Bruker maXis Impact | LC-ESI-QTOF | 40 eV | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218111 | Bruker maXis Impact | LC-ESI-QTOF | 50 eV | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218130 | Bruker maXis Impact | LC-ESI-QTOF | 10 eV | [M+Na]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218131 | Bruker maXis Impact | LC-ESI-QTOF | 20 eV | [M+Na]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218132 | Bruker maXis Impact | LC-ESI-QTOF | 30 eV | [M+Na]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218133 | Bruker maXis Impact | LC-ESI-QTOF | 40 eV | [M+Na]+ | POSITIVE | MS2 |
| MSBNK-Athens_Univ-AU218151 | Bruker maXis Impact | LC-ESI-QTOF | 10 eV | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Athens_Univ-AU218152 | Bruker maXis Impact | LC-ESI-QTOF | 20 eV | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Athens_Univ-AU218153 | Bruker maXis Impact | LC-ESI-QTOF | 30 eV | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Athens_Univ-AU218154 | Bruker maXis Impact | LC-ESI-QTOF | 40 eV | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Athens_Univ-AU218155 | Bruker maXis Impact | LC-ESI-QTOF | 50 eV | [M-H]- | NEGATIVE | MS2 |
| MSBNK-Eawag-EA285501 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 35 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285502 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 15 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285503 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 30 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285504 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 45 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285505 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 60 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285506 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 75 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285507 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 90 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285508 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 15 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285509 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 30 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285510 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 45 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285511 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 60 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285512 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 75 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285513 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 90 % (nominal) | [M+H]+ | POSITIVE | MS2 |
| MSBNK-Eawag-EA285514 | LTQ Orbitrap XL Thermo Scienti... | LC-ESI-ITFT | 35 % (nominal) | [M+H]+ | POSITIVE | MS2 |