#METABOLOMICS WORKBENCH epannkuk_20210512_073836 DATATRACK_ID:2637 STUDY_ID:ST001792 ANALYSIS_ID:AN002908 PROJECT_ID:000000
VERSION             	1
CREATED_ON             	May 12, 2021, 9:30 am
#PROJECT
PR:PROJECT_TITLE                 	LDR_mouse_biofluid_metabolomics
PR:PROJECT_SUMMARY               	An important component of ionizing radiation (IR) exposure after a radiological
PR:PROJECT_SUMMARY               	incident may include low-dose rate (LDR) exposures either externally or
PR:PROJECT_SUMMARY               	internally, such as from 137Cs deposition. LDR exposures can have different
PR:PROJECT_SUMMARY               	effects compared to acute high-dose rate exposures from a health and
PR:PROJECT_SUMMARY               	biodosimetry perspective. In this study, a novel irradiation system, VAriable
PR:PROJECT_SUMMARY               	Dose-rate External 137Cs irradiatoR (VADER), was used to expose male and female
PR:PROJECT_SUMMARY               	mice to a variable LDR over a 30-day time span to cumulative doses of 1 (only in
PR:PROJECT_SUMMARY               	males), 2, 2.8, 4.1, 8.8 (only in males), or 9.7 Gy to simulate fall-out type
PR:PROJECT_SUMMARY               	exposures. Urine and serum from mice exposed to an acute dose (~0.8 Gy/min) of
PR:PROJECT_SUMMARY               	x-rays were collected in parallel. Radiation markers were identified by global
PR:PROJECT_SUMMARY               	mass spectrometry based metabolomics and the machine learning algorithm Random
PR:PROJECT_SUMMARY               	Forests.
PR:INSTITUTE                     	Georgetown University
PR:LAST_NAME                     	Pannkuk
PR:FIRST_NAME                    	Evan
PR:ADDRESS                       	3970 Reservoir Rd, NW New Research Building E504
PR:EMAIL                         	elp44@georgetown.edu
PR:PHONE                         	2026875650
#STUDY
ST:STUDY_TITLE                   	Effect of external low-dose rate radiation on mouse biofluid metabolomic
ST:STUDY_TITLE                   	signatures
ST:STUDY_SUMMARY                 	An important component of ionizing radiation (IR) exposure after a radiological
ST:STUDY_SUMMARY                 	incident may include low-dose rate (LDR) exposures either externally or
ST:STUDY_SUMMARY                 	internally, such as from 137Cs deposition. LDR exposures can have different
ST:STUDY_SUMMARY                 	effects compared to acute high-dose rate exposures from a health and
ST:STUDY_SUMMARY                 	biodosimetry perspective. In this study, a novel irradiation system, VAriable
ST:STUDY_SUMMARY                 	Dose-rate External 137Cs irradiatoR (VADER), was used to expose male and female
ST:STUDY_SUMMARY                 	mice to a variable LDR over a 30-day time span to cumulative doses of 1 (only in
ST:STUDY_SUMMARY                 	males), 2, 2.8, 4.1, 8.8 (only in males), or 9.7 Gy to simulate fall-out type
ST:STUDY_SUMMARY                 	exposures. Urine and serum from mice exposed to an acute dose (~0.8 Gy/min) of
ST:STUDY_SUMMARY                 	x-rays were collected in parallel. Radiation markers were identified by global
ST:STUDY_SUMMARY                 	mass spectrometry based metabolomics and the machine learning algorithm Random
ST:STUDY_SUMMARY                 	Forests.
ST:INSTITUTE                     	Georgetown University
ST:LAST_NAME                     	Pannkuk
ST:FIRST_NAME                    	Evan
ST:ADDRESS                       	3970 Reservoir Rd, NW New Research Building E504
ST:EMAIL                         	elp44@georgetown.edu
ST:PHONE                         	2026875650
#SUBJECT
SU:SUBJECT_TYPE                  	Mammal
SU:SUBJECT_SPECIES               	Mus musculus
SU:TAXONOMY_ID                   	10090
SU:GENDER                        	Male
#SUBJECT_SAMPLE_FACTORS:         	SUBJECT(optional)[tab]SAMPLE[tab]FACTORS(NAME:VALUE pairs separated by |)[tab]Raw file names and additional sample data
SUBJECT_SAMPLE_FACTORS           	114V	12	Factor:LDR | Factor:D5	RAW_FILE_NAME=vader_met_12
SUBJECT_SAMPLE_FACTORS           	93A	13	Factor:Control | Factor:D3	RAW_FILE_NAME=vader_met_13
SUBJECT_SAMPLE_FACTORS           	63A	14	Factor:HDR | Factor:D1	RAW_FILE_NAME=vader_met_14
SUBJECT_SAMPLE_FACTORS           	113V	15	Factor:LDR | Factor:D5	RAW_FILE_NAME=vader_met_15
SUBJECT_SAMPLE_FACTORS           	123V	16	Factor:LDR | Factor:D20	RAW_FILE_NAME=vader_met_16
SUBJECT_SAMPLE_FACTORS           	159V	19	Factor:Control | Factor:D30	RAW_FILE_NAME=vader_met_19
SUBJECT_SAMPLE_FACTORS           	99A	20	Factor:Control | Factor:D5	RAW_FILE_NAME=vader_met_20
SUBJECT_SAMPLE_FACTORS           	153V	21	Factor:Control | Factor:D20	RAW_FILE_NAME=vader_met_21
SUBJECT_SAMPLE_FACTORS           	151V	22	Factor:Control | Factor:D20	RAW_FILE_NAME=vader_met_22
SUBJECT_SAMPLE_FACTORS           	89A	23	Factor:Control | Factor:D2	RAW_FILE_NAME=vader_met_23
SUBJECT_SAMPLE_FACTORS           	87A	29	Factor:Control | Factor:D2	RAW_FILE_NAME=vader_met_29
SUBJECT_SAMPLE_FACTORS           	90A	30	Factor:Control | Factor:D2	RAW_FILE_NAME=vader_met_30
SUBJECT_SAMPLE_FACTORS           	115V	31	Factor:LDR | Factor:D5	RAW_FILE_NAME=vader_met_31
SUBJECT_SAMPLE_FACTORS           	72A	32	Factor:HDR | Factor:D3	RAW_FILE_NAME=vader_met_32
SUBJECT_SAMPLE_FACTORS           	186V	33	Factor:Control | Factor:D3	RAW_FILE_NAME=vader_met_33
SUBJECT_SAMPLE_FACTORS           	77A	36	Factor:HDR | Factor:D5	RAW_FILE_NAME=vader_met_36
SUBJECT_SAMPLE_FACTORS           	100A	37	Factor:Control | Factor:D5	RAW_FILE_NAME=vader_met_37
SUBJECT_SAMPLE_FACTORS           	172V	38	Factor:LDR | Factor:D2	RAW_FILE_NAME=vader_met_38
SUBJECT_SAMPLE_FACTORS           	130V	39	Factor:LDR | Factor:D30	RAW_FILE_NAME=vader_met_39
SUBJECT_SAMPLE_FACTORS           	126V	40	Factor:LDR | Factor:D30	RAW_FILE_NAME=vader_met_40
SUBJECT_SAMPLE_FACTORS           	75A	46	Factor:HDR | Factor:D3	RAW_FILE_NAME=vader_met_46
SUBJECT_SAMPLE_FACTORS           	171V	47	Factor:LDR | Factor:D2	RAW_FILE_NAME=vader_met_47
SUBJECT_SAMPLE_FACTORS           	158V	48	Factor:Control | Factor:D30	RAW_FILE_NAME=vader_met_48
SUBJECT_SAMPLE_FACTORS           	176V	49	Factor:Control | Factor:D2	RAW_FILE_NAME=vader_met_49
SUBJECT_SAMPLE_FACTORS           	156V	50	Factor:Control | Factor:D30	RAW_FILE_NAME=vader_met_50
SUBJECT_SAMPLE_FACTORS           	152V	53	Factor:Control | Factor:D20	RAW_FILE_NAME=vader_met_53
SUBJECT_SAMPLE_FACTORS           	70A	54	Factor:HDR | Factor:D2	RAW_FILE_NAME=vader_met_54
SUBJECT_SAMPLE_FACTORS           	95A	55	Factor:Control | Factor:D3	RAW_FILE_NAME=vader_met_55
SUBJECT_SAMPLE_FACTORS           	157V	56	Factor:Control | Factor:D30	RAW_FILE_NAME=vader_met_56
SUBJECT_SAMPLE_FACTORS           	5V	57	Factor:LDR | Factor:D1	RAW_FILE_NAME=vader_met_57
SUBJECT_SAMPLE_FACTORS           	178V	63	Factor:Control | Factor:D2	RAW_FILE_NAME=vader_met_63
SUBJECT_SAMPLE_FACTORS           	67A	64	Factor:HDR | Factor:D2	RAW_FILE_NAME=vader_met_64
SUBJECT_SAMPLE_FACTORS           	112V	65	Factor:LDR | Factor:D5	RAW_FILE_NAME=vader_met_65
SUBJECT_SAMPLE_FACTORS           	2V	66	Factor:LDR | Factor:D1	RAW_FILE_NAME=vader_met_66
SUBJECT_SAMPLE_FACTORS           	96A	67	Factor:Control | Factor:D5	RAW_FILE_NAME=vader_met_67
SUBJECT_SAMPLE_FACTORS           	160V	70	Factor:Control | Factor:D30	RAW_FILE_NAME=vader_met_70
SUBJECT_SAMPLE_FACTORS           	97A	71	Factor:Control | Factor:D5	RAW_FILE_NAME=vader_met_71
SUBJECT_SAMPLE_FACTORS           	84A	72	Factor:Control | Factor:D1	RAW_FILE_NAME=vader_met_72
SUBJECT_SAMPLE_FACTORS           	122V	73	Factor:LDR | Factor:D20	RAW_FILE_NAME=vader_met_73
SUBJECT_SAMPLE_FACTORS           	174V	74	Factor:LDR | Factor:D2	RAW_FILE_NAME=vader_met_74
SUBJECT_SAMPLE_FACTORS           	88A	80	Factor:Control | Factor:D2	RAW_FILE_NAME=vader_met_80
SUBJECT_SAMPLE_FACTORS           	173V	81	Factor:LDR | Factor:D2	RAW_FILE_NAME=vader_met_81
SUBJECT_SAMPLE_FACTORS           	69A	82	Factor:HDR | Factor:D2	RAW_FILE_NAME=vader_met_82
SUBJECT_SAMPLE_FACTORS           	154V	83	Factor:Control | Factor:D20	RAW_FILE_NAME=vader_met_83
SUBJECT_SAMPLE_FACTORS           	82A	84	Factor:Control | Factor:D1	RAW_FILE_NAME=vader_met_84
SUBJECT_SAMPLE_FACTORS           	68A	87	Factor:HDR | Factor:D2	RAW_FILE_NAME=vader_met_87
SUBJECT_SAMPLE_FACTORS           	71A	88	Factor:HDR | Factor:D3	RAW_FILE_NAME=vader_met_88
SUBJECT_SAMPLE_FACTORS           	183V	89	Factor:LDR | Factor:D3	RAW_FILE_NAME=vader_met_89
SUBJECT_SAMPLE_FACTORS           	3V	90	Factor:LDR | Factor:D1	RAW_FILE_NAME=vader_met_90
SUBJECT_SAMPLE_FACTORS           	155V	91	Factor:Control | Factor:D20	RAW_FILE_NAME=vader_met_91
SUBJECT_SAMPLE_FACTORS           	175V	97	Factor:LDR | Factor:D2	RAW_FILE_NAME=vader_met_97
SUBJECT_SAMPLE_FACTORS           	62A	98	Factor:HDR | Factor:D1	RAW_FILE_NAME=vader_met_98
SUBJECT_SAMPLE_FACTORS           	190V	99	Factor:Control | Factor:D3	RAW_FILE_NAME=vader_met_99
SUBJECT_SAMPLE_FACTORS           	141V	100	Factor:Control | Factor:D5	RAW_FILE_NAME=vader_met_100
SUBJECT_SAMPLE_FACTORS           	85A	101	Factor:Control | Factor:D1	RAW_FILE_NAME=vader_met_101
SUBJECT_SAMPLE_FACTORS           	177V	104	Factor:Control | Factor:D2	RAW_FILE_NAME=vader_met_104
SUBJECT_SAMPLE_FACTORS           	78A	105	Factor:HDR | Factor:D5	RAW_FILE_NAME=vader_met_105
SUBJECT_SAMPLE_FACTORS           	64A	106	Factor:HDR | Factor:D1	RAW_FILE_NAME=vader_met_106
SUBJECT_SAMPLE_FACTORS           	184V	107	Factor:LDR | Factor:D3	RAW_FILE_NAME=vader_met_107
SUBJECT_SAMPLE_FACTORS           	143V	108	Factor:Control | Factor:D5	RAW_FILE_NAME=vader_met_108
SUBJECT_SAMPLE_FACTORS           	94A	114	Factor:Control | Factor:D3	RAW_FILE_NAME=vader_met_114
SUBJECT_SAMPLE_FACTORS           	4V	115	Factor:LDR | Factor:D1	RAW_FILE_NAME=vader_met_115
SUBJECT_SAMPLE_FACTORS           	180V	116	Factor:Control | Factor:D2	RAW_FILE_NAME=vader_met_116
SUBJECT_SAMPLE_FACTORS           	80A	117	Factor:HDR | Factor:D5	RAW_FILE_NAME=vader_met_117
SUBJECT_SAMPLE_FACTORS           	121V	118	Factor:LDR | Factor:D20	RAW_FILE_NAME=vader_met_118
SUBJECT_SAMPLE_FACTORS           	66A	121	Factor:HDR | Factor:D2	RAW_FILE_NAME=vader_met_121
SUBJECT_SAMPLE_FACTORS           	187V	122	Factor:Control | Factor:D3	RAW_FILE_NAME=vader_met_122
SUBJECT_SAMPLE_FACTORS           	86A	123	Factor:Control | Factor:D2	RAW_FILE_NAME=vader_met_123
SUBJECT_SAMPLE_FACTORS           	92A	124	Factor:Control | Factor:D3	RAW_FILE_NAME=vader_met_124
SUBJECT_SAMPLE_FACTORS           	185V	125	Factor:LDR | Factor:D3	RAW_FILE_NAME=vader_met_125
SUBJECT_SAMPLE_FACTORS           	179V	131	Factor:Control | Factor:D2	RAW_FILE_NAME=vader_met_131
SUBJECT_SAMPLE_FACTORS           	144V	132	Factor:Control | Factor:D5	RAW_FILE_NAME=vader_met_132
SUBJECT_SAMPLE_FACTORS           	189V	133	Factor:Control | Factor:D3	RAW_FILE_NAME=vader_met_133
SUBJECT_SAMPLE_FACTORS           	124V	134	Factor:LDR | Factor:D20	RAW_FILE_NAME=vader_met_134
SUBJECT_SAMPLE_FACTORS           	33V	135	Factor:Control | Factor:D1	RAW_FILE_NAME=vader_met_135
SUBJECT_SAMPLE_FACTORS           	73A	138	Factor:HDR | Factor:D3	RAW_FILE_NAME=vader_met_138
SUBJECT_SAMPLE_FACTORS           	81A	139	Factor:Control | Factor:D1	RAW_FILE_NAME=vader_met_139
SUBJECT_SAMPLE_FACTORS           	128V	140	Factor:LDR | Factor:D30	RAW_FILE_NAME=vader_met_140
SUBJECT_SAMPLE_FACTORS           	127V	141	Factor:LDR | Factor:D30	RAW_FILE_NAME=vader_met_141
SUBJECT_SAMPLE_FACTORS           	111V	142	Factor:LDR | Factor:D5	RAW_FILE_NAME=vader_met_142
SUBJECT_SAMPLE_FACTORS           	65A	148	Factor:HDR | Factor:D1	RAW_FILE_NAME=vader_met_148
SUBJECT_SAMPLE_FACTORS           	1V	149	Factor:LDR | Factor:D1	RAW_FILE_NAME=vader_met_149
SUBJECT_SAMPLE_FACTORS           	181V	150	Factor:LDR | Factor:D3	RAW_FILE_NAME=vader_met_150
SUBJECT_SAMPLE_FACTORS           	142V	151	Factor:Control | Factor:D5	RAW_FILE_NAME=vader_met_151
SUBJECT_SAMPLE_FACTORS           	182V	152	Factor:LDR | Factor:D3	RAW_FILE_NAME=vader_met_152
SUBJECT_SAMPLE_FACTORS           	188V	155	Factor:Control | Factor:D3	RAW_FILE_NAME=vader_met_155
SUBJECT_SAMPLE_FACTORS           	145V	156	Factor:Control | Factor:D5	RAW_FILE_NAME=vader_met_156
SUBJECT_SAMPLE_FACTORS           	83A	157	Factor:Control | Factor:D1	RAW_FILE_NAME=vader_met_157
SUBJECT_SAMPLE_FACTORS           	76A	158	Factor:HDR | Factor:D5	RAW_FILE_NAME=vader_met_158
SUBJECT_SAMPLE_FACTORS           	129V	159	Factor:LDR | Factor:D30	RAW_FILE_NAME=vader_met_159
SUBJECT_SAMPLE_FACTORS           	34V	165	Factor:Control | Factor:D1	RAW_FILE_NAME=vader_met_165
SUBJECT_SAMPLE_FACTORS           	61A	166	Factor:HDR | Factor:D1	RAW_FILE_NAME=vader_met_166
SUBJECT_SAMPLE_FACTORS           	125V	167	Factor:LDR | Factor:D20	RAW_FILE_NAME=vader_met_167
SUBJECT_SAMPLE_FACTORS           	91A	168	Factor:Control | Factor:D3	RAW_FILE_NAME=vader_met_168
SUBJECT_SAMPLE_FACTORS           	32V	169	Factor:Control | Factor:D1	RAW_FILE_NAME=vader_met_169
SUBJECT_SAMPLE_FACTORS           	79A	172	Factor:HDR | Factor:D5	RAW_FILE_NAME=vader_met_172
SUBJECT_SAMPLE_FACTORS           	35V	173	Factor:Control | Factor:D1	RAW_FILE_NAME=vader_met_173
SUBJECT_SAMPLE_FACTORS           	98A	174	Factor:Control | Factor:D5	RAW_FILE_NAME=vader_met_174
SUBJECT_SAMPLE_FACTORS           	74A	175	Factor:HDR | Factor:D3	RAW_FILE_NAME=vader_met_175
#COLLECTION
CO:COLLECTION_SUMMARY            	Serum was collected after irradiation
CO:SAMPLE_TYPE                   	Blood (serum)
#TREATMENT
TR:TREATMENT_SUMMARY             	The VADER was designed to deliver controlled dose rates in the range 0.1 – 1
TR:TREATMENT_SUMMARY             	Gy/day to a cohort of up to 15 mice. The VADER uses ~0.5 Ci of retired 137Cs
TR:TREATMENT_SUMMARY             	brachytherapy seeds that are arranged in two platters placed above and below a
TR:TREATMENT_SUMMARY             	“mouse hotel”. The platters can be placed ~0.5 – 60 cm above and below the
TR:TREATMENT_SUMMARY             	mouse hotel allowing implementation of time-variable dose rates. Offline
TR:TREATMENT_SUMMARY             	dosimetry of the VADER was performed annually using a NIST traceable 10x6-6
TR:TREATMENT_SUMMARY             	ionization chamber (Radcal Corp., Monrovia, CA). Dose uniformity across the
TR:TREATMENT_SUMMARY             	surface was measured using EBT3 film (Ashland, Covington, KY, USA) and the
TR:TREATMENT_SUMMARY             	variation was 15% across the hotel. A lead and high-density concrete brick
TR:TREATMENT_SUMMARY             	shield ensured minimal radiation doses to occupationally exposed personnel
TR:TREATMENT_SUMMARY             	(operators) inside (< 0.1 mGy/wk) and outside the room (< 0.02 mGy/wk). The
TR:TREATMENT_SUMMARY             	mouse hotel consists of an acrylic box (35 x 35 x 12 cm) allowing housing of ≤
TR:TREATMENT_SUMMARY             	15 mice with bedding material and food/water ad libitum. Temperature (20 –
TR:TREATMENT_SUMMARY             	25°C), humidity (40 – 60%), airflow and lighting were fully controlled to
TR:TREATMENT_SUMMARY             	required animal care standards (temperature/humidity sensor, HWg HTemp, TruePath
TR:TREATMENT_SUMMARY             	Technologies Victor, NY). Environmental controls and monitoring were integrated
TR:TREATMENT_SUMMARY             	into the mouse hotel for easy replacement in case of radiation damage. Mice were
TR:TREATMENT_SUMMARY             	monitored in real time using a 180° fisheye ELP USB camera (Amazon).
#SAMPLEPREP
SP:SAMPLEPREP_SUMMARY            	Samples were prepared and analyzed as previously described.18, 19 Briefly, serum
SP:SAMPLEPREP_SUMMARY            	(5 μl) was deproteinized (195 μl 66% cold acetonitrile [ACN]) with internal
SP:SAMPLEPREP_SUMMARY            	standards (2 μM debrisoquine [M+H]+ = 176.1188; 30 μM 4-nitrobenzoic acid
SP:SAMPLEPREP_SUMMARY            	[M-H]- = 166.0141), vortexed, incubated on ice (10 min), and centrifuged for 10
SP:SAMPLEPREP_SUMMARY            	min (max speed, 4 °C).
SP:PROCESSING_STORAGE_CONDITIONS 	-80℃
#CHROMATOGRAPHY
CH:CHROMATOGRAPHY_SUMMARY        	Mobile phases consisted of the following: solvent A (water/0.1% formic acid
CH:CHROMATOGRAPHY_SUMMARY        	[FA]), solvent B (ACN/0.1% FA), solvent C (isopropanol [IPA]/ACN (90:10)/0.1%
CH:CHROMATOGRAPHY_SUMMARY        	FA). The gradient for urine was (solvent A and B) 4.0 min 5% B, 4.0 min 20% B,
CH:CHROMATOGRAPHY_SUMMARY        	5.1 min 95% B, and 1.9 min 5% B at a flow rate of 0.5 ml/min. The gradient for
CH:CHROMATOGRAPHY_SUMMARY        	serum was (solvent A, B, and C) 4.0 min 98:2 A:B, 4.0 min 40:60 A:B, 1.5 min
CH:CHROMATOGRAPHY_SUMMARY        	2:98 A:B, 2.0 min 2:98 A:C, 0.5 min 50:50 A:C, and 1.0 min 98:2 A:B at a flow
CH:CHROMATOGRAPHY_SUMMARY        	rate of 0.5 ml/min.
CH:CHROMATOGRAPHY_TYPE           	Reversed phase
CH:INSTRUMENT_NAME               	Waters Acquity
CH:COLUMN_NAME                   	Waters Acquity BEH C18 (50 x 2.1mm, 1.7 um)
#ANALYSIS
AN:ANALYSIS_TYPE                 	MS
#MS
MS:INSTRUMENT_NAME               	Waters Synapt G2 S QTOF
MS:INSTRUMENT_TYPE               	QTOF
MS:MS_TYPE                       	ESI
MS:ION_MODE                      	NEGATIVE
MS:MS_COMMENTS                   	Negative and positive electrospray ionization (ESI) data-independent modes were
MS:MS_COMMENTS                   	used for data acquisition with leucine enkephalin ([M+H]+ = 556.2771, [M-H]- =
MS:MS_COMMENTS                   	554.2615) as Lock-Spray®. Operating conditions for ESI were: capillary voltage
MS:MS_COMMENTS                   	2.75 kV, cone voltage 30 V, desolvation temperature 500°C, desolvation gas flow
MS:MS_COMMENTS                   	1000 L/Hr.
MS:MS_RESULTS_FILE               	ST001792_AN002908_Results.txt	UNITS:peak area	Has m/z:Yes	Has RT:Yes	RT units:Minutes
#END