Summary of Study ST000602
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000439. The data can be accessed directly via it's Project DOI: 10.21228/M8TX3S This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
Study ID | ST000602 |
Study Title | PIXiE: An Algorithm for Automated Ion Mobility Arrival Time Extraction and Collision Cross Section Calculation using Global Data Association |
Study Summary | Motivation: Drift tube ion mobility spectrometry coupled with mass spectrometry (DTIMS-MS) is increasingly implemented in high throughput omics workflows, and new informatics approaches are necessary for processing the associated data. To automatically extract arrival times for molecules measured by DTIMS at multiple electric fields and compute their associated collisional cross sections (CCS), we created the PNNL Ion Mobility Cross Section Extractor (PIXiE). The primary application presented for this algorithm is the extraction of that can then be used to create a reference library of CCS valuesinformation necessary to create a reference library containing accurate masses, DTIMS arrival times and CCSs for use in high throughput omics analyses. Results: We demonstrate the utility of this approach by automatically extracting arrival times and calculating the associated CCSs for a set of endogenous metabolites and xenobiotics. The PIXiE-generated CCS values were within error of those calculated using commercially available instrument vendor software. |
Institute | Pacific Northwest National Laboratory |
Last Name | Casey |
First Name | Cameron |
Address | 902 Battelle Blvd, Richland, WA 99354 |
cameron.casey@pnnl.gov | |
Phone | 5093716612 |
Submit Date | 2017-04-03 |
Raw Data Available | Yes |
Raw Data File Type(s) | uimf |
Analysis Type Detail | LC-MS |
Release Date | 2017-07-10 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Project:
Project ID: | PR000439 |
Project DOI: | doi: 10.21228/M8TX3S |
Project Title: | PIXiE: An Algorithm for Automated Ion Mobility Arrival Time Extraction and Collision Cross Section Calculation using Global Data Association |
Project Summary: | Motivation: Drift tube ion mobility spectrometry coupled with mass spectrometry (DTIMS-MS) is increasingly implemented in high throughput omics workflows, and new informatics approaches are necessary for processing the associated data. To automatically extract arrival times for molecules measured by DTIMS at multiple electric fields and compute their associated collisional cross sections (CCS), we created the PNNL Ion Mobility Cross Section Extractor (PIXiE). The primary application presented for this algorithm is the extraction of that can then be used to create a reference library of CCS values for use in high throughput omics analyses. Results: We demonstrate the utility of this approach by automatically extracting arrival times and calculating the associated CCSs for a set of endogenous metabolites and xenobiotics. The PIXiE-generated CCS values were within error of those calculated using commercially available instrument vendor software. |
Institute: | Pacific Northwest National Laboratory |
Last Name: | Casey |
First Name: | Cameron |
Address: | 902 Battelle Blvd, Richland, WA 99354 |
Email: | cameron.casey@pnnl.gov |
Phone: | 5093716612 |
Subject:
Subject ID: | SU001172 |
Subject Type: | Standards |
Subject Species: | Standard |
Factors:
Subject type: Standards; Subject species: Standard (Factor headings shown in green)
mb_sample_id | local_sample_id | Sample Type |
---|---|---|
SA076999 | CCS_Pos-3_3616-42-0_7Jul16_Beech_Infuse | Standard |
SA077000 | CCS_Pos-2_59-30-3_30Jun16_Beech_Infuse | Standard |
SA077001 | CCS_Pos-1_57-50-1_30Jun16_Beech_Infuse | Standard |
SA077002 | CCS_Pos-3_58-61-7_7Jul16_Beech_Infuse | Standard |
SA077003 | CCS_Pos-1_65-46-3_30Jun16_Beech_Infuse | Standard |
SA077004 | CCS_Pos-3_62-49-7_7Jul16_Beech_Infuse | Standard |
SA077005 | CCS-Pos-1-70-18-8_20Jul16_Beech_Infuse | Standard |
SA077006 | CCS-Neg-1-70-18-8_23Jul16_Beech_Infuse | Standard |
SA077007 | EXP-PMR_pos2_9Oct14_Columbia_DI | Standard |
SA077008 | CCS_Pos-1_53-84-9_30Jun16_Beech_Infuse | Standard |
SA077009 | CCS_Pos-1_153-94-6_30Jun16_Beech_Infuse | Standard |
SA077010 | CCS_Neg-3_137868-52-1_7Jul16_Beech_Infuse | Standard |
SA077011 | CCS_Neg-2_57-50-1_7Jul16_Beech_Infuse | Standard |
SA077012 | CCS_Neg-2_53-84-9_7Jul16_Beech_Infuse | Standard |
SA077013 | CCS_Neg-1_59-30-3_7Jul16_Beech_Infuse | Standard |
SA077014 | CCS_Neg-3_3616-42-0_7Jul16_Beech_Infuse | Standard |
SA077015 | CCS_Neg-3_38099-82-0_7Jul16_Beech_Infuse | Standard |
SA077016 | CCS_Pos-1_107-35-7_30Jun16_Beech_Infuse | Standard |
SA077017 | CCS_Neg-3_58-61-7_7Jul16_Beech_Infuse | Standard |
SA077018 | CCS_Neg-3_51-43-4_7Jul16_Beech_Infuse | Standard |
SA077019 | CCS_Neg-1_153-94-6_7Jul16_Beech_Infuse | Standard |
Showing results 1 to 21 of 21 |
Collection:
Collection ID: | CO001166 |
Collection Summary: | Authentic standards were purchased from Sigma Aldrich (St. Louis, MO). |
Sample Type: | Synthetic Mixture |
Treatment:
Treatment ID: | TR001186 |
Treatment Summary: | Standards were not treated. |
Sample Preparation:
Sampleprep ID: | SP001179 |
Sampleprep Summary: | Standards were prepared in 100% methanol to a concentration of 1 µM. |
Combined analysis:
Analysis ID | AN001824 |
---|---|
Analysis type | MS |
Chromatography type | Unspecified |
Chromatography system | Agilent 6560 |
Column | N/A |
MS Type | ESI |
MS instrument type | QTOF |
MS instrument name | Agilent 6560 Ion Mobility |
Ion Mode | UNSPECIFIED |
Units |
Chromatography:
Chromatography ID: | CH001293 |
Instrument Name: | Agilent 6560 |
Column Name: | N/A |
Chromatography Type: | Unspecified |
MS:
MS ID: | MS001687 |
Analysis ID: | AN001824 |
Instrument Name: | Agilent 6560 Ion Mobility |
Instrument Type: | QTOF |
MS Type: | ESI |
Ion Mode: | UNSPECIFIED |