MoNA MS database records for Atalaphylline
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
VF-NPL-QTOF003250 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF006786 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003251 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF006787 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003252 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF006788 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M-H]- | negative | MS2 |
VF-NPL-QTOF003247 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF006789 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 10 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003248 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF006790 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 20 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF003249 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
VF-NPL-QTOF006791 | Agilent 6530 Q-TOF | LC-ESI-QTOF | - | 40 V | [M+H]+ | positive | MS2 |
CCMSLIB00000846702 | Maxis II HD Q-TOF Bruker | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00000845597 | Maxis II HD Q-TOF Bruker | - | - | - | [M+H]+ | positive | MS2 |
VF-NPL-LTQ004777 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ004778 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS5 Composite |
VF-NPL-LTQ004775 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2 |
VF-NPL-LTQ004776 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | positive | MS2-MS5 Composite |
VF-NPL-QEHF018772 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF018773 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF018774 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF018769 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF018770 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF018771 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF018778 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF018779 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF018780 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+K]+ | positive | MS2 |
VF-NPL-QEHF018775 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF018776 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF018777 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+Na]+ | positive | MS2 |
VF-NPL-QEHF018781 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF018782 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+NH4]+ | positive | MS2 |
VF-NPL-QEHF018783 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+NH4]+ | positive | MS2 |