MoNA MS database records for L-Asparagine
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
CCMSLIB00000578143 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005463998 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005720644 | qTof | - | - | - | [M-H]- | negative | MS2 |
EMBL-MCF_spec28318 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec379930 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H2O-H]- | negative | MS2 |
EMBL-MCF_spec379938 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H]- | negative | MS2 |
EMBL-MCF_spec379948 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H2O-H]- | negative | MS2 |
EMBL-MCF_spec379953 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 33.33 eV | [M-H]- | negative | MS2 |
FiehnHILIC001081 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC002606 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M-H]- | negative | MS2 |
KNA00483 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | negative | MS1 |
KNA00484 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M-H]- | negative | MS2 |
KNA00485 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M]- | negative | MS2 |
KNA00486 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [2M-H]- | negative | MS2 |
KNA00736 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | negative | MS1 |
KNA00737 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | negative | MS2 |
KNA00738 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M-H]- | negative | MS2 |
KNA00739 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [2M-H]- | negative | MS2 |
KO000024 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M-H]- | negative | MS2 |
KO000025 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M-H]- | negative | MS2 |
KO000026 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M-H]- | negative | MS2 |
KO000027 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M-H]- | negative | MS2 |
KO000028 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M-H]- | negative | MS2 |
MoNA017778 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
MoNA017779 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
MoNA017780 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M-H]- | negative | MS2 |
MoNA024292 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA034727 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034728 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA034731 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
MoNA038118 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
PM000980 | API 2000 | QqQ | ESI | -12 | [M-H]- | negative | MS2 |
RP001511 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
RP001512 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
CCMSLIB00000577910 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005463981 | Orbitrap | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005463982 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00005720354 | qTof | - | - | - | [M+H]+ | positive | MS2 |
EMBL-MCF_spec103531 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec354413 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M+H]+ | positive | MS2 |
EMBL-MCF_spec354445 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 30.0 eV | [M+H]+ | positive | MS2 |
FiehnHILIC000202 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
FiehnHILIC001775 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
FiehnLib000964 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000965 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000966 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000967 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000968 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
GLS00010 | GCMS-2010 Plus, Shimadzu | EI-B | - | - | - | positive | MS1 |
HMDB0000168_ms_ms_266 | GCMS-2010 Plus, Shimadzu | Quattro_QQQ | - | - | - | positive | - |
HMDB0000168_ms_ms_267 | GCMS-2010 Plus, Shimadzu | Quattro_QQQ | - | - | - | positive | - |
HMDB0000168_ms_ms_268 | GCMS-2010 Plus, Shimadzu | Quattro_QQQ | - | - | - | positive | - |
KNA00045 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
KNA00046 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
KNA00048 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [2M+H]+ | positive | MS2 |
KNA00352 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS1 |
KNA00353 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [M+H]+ | positive | MS2 |
KNA00354 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | - | positive | MS2 |
KNA00355 | LTQ Orbitrap XL, Thermo Scient... | LC-ESI-ITFT | ESI | 35eV | [2M+H]+ | positive | MS2 |
KO002058 | API3000, Applied Biosystems | LC-ESI-QQ | - | 10 V | [M+H]+ | positive | MS2 |
KO002059 | API3000, Applied Biosystems | LC-ESI-QQ | - | 20 V | [M+H]+ | positive | MS2 |
KO002060 | API3000, Applied Biosystems | LC-ESI-QQ | - | 30 V | [M+H]+ | positive | MS2 |
KO002061 | API3000, Applied Biosystems | LC-ESI-QQ | - | 40 V | [M+H]+ | positive | MS2 |
KO002062 | API3000, Applied Biosystems | LC-ESI-QQ | - | 50 V | [M+H]+ | positive | MS2 |
KZ000041 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
KZ000148 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
MoNA002281 | Agilent QTOF 6550 | LC-ESI-QTOF | - | 20 | [M+H]+ | positive | MS2 |
MoNA002405 | Agilent QTOF 6550 | - | - | - | - | positive | MS1 |
MoNA002500 | Agilent QTOF 6550 | - | - | - | - | positive | MS1 |
MoNA002515 | Agilent QTOF 6550 | - | - | - | - | positive | MS1 |
MoNA002525 | Agilent QTOF 6550 | - | - | - | - | positive | MS1 |
MoNA003275 | Agilent QTOF 6550 | - | Electrospray Ionization (ESI) | - | [M+H]+ | positive | MS2 |
MoNA003276 | Agilent QTOF 6550 | - | Electrospray Ionization (ESI) | - | [M+H]+ | positive | MS2 |
MoNA003277 | Agilent QTOF 6550 | - | Electrospray Ionization (ESI) | - | [M+H]+ | positive | MS2 |
MoNA003278 | Agilent QTOF 6550 | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 50(NCE) | [M+H]+ | positive | MS2 |
MoNA003279 | Agilent QTOF 6550 | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 70(NCE) | [M+H]+ | positive | MS2 |
MoNA003280 | Agilent QTOF 6550 | LC-ESI-Q-Orbitrap | Electrospray Ionization (ESI) | 90(NCE) | [M+H]+ | positive | MS2 |
MoNA010938 | Agilent 6550 iFunnel | Q-TOF | - | 10 | [M+H]+ | positive | - |
MoNA010939 | Agilent 6550 iFunnel | Q-TOF | - | 20 | [M+H]+ | positive | - |
MoNA010940 | Agilent 6550 iFunnel | Q-TOF | - | 30 | [M+H]+ | positive | - |
MoNA010941 | Agilent 6550 iFunnel | Q-TOF | - | 40 | [M+H]+ | positive | - |
MoNA011485 | Thermo Fisher Scientific Trace... | - | - | - | [M-CH3]+ | positive | MS2 |
MoNA016664 | XEVO-G2S | LC-ESI-QTOF | - | 6V (MS1); Ramp 15V-30V (MSE) | [M+H]+ | positive | - |
MoNA018952 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA018953 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA018954 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA018955 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA018956 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA018957 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA019609 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
MoNA019610 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
MoNA019611 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M+H]+ | positive | MS2 |
MoNA019612 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
MoNA024271 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
MoNA032602 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA032603 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA032605 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA036461 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M+H]+ | positive | MS2 |
MoNA036462 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M+H]+ | positive | MS2 |
MoNA036463 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M+H]+ | positive | MS2 |
MoNA037030 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA037371 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038473 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MoNA038698 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
OUF00299 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
OUF01013 | Agilent 7000B QqQMS, Agilent; ... | GC-EI-QQ | - | - | - | positive | MS1 |
PB000456 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 10 eV | [M+H]+ | positive | MS2 |
PB000457 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 15 eV | [M+H]+ | positive | MS2 |
PB000458 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 20 eV | [M+H]+ | positive | MS2 |
PB000459 | API QSTAR Pulsar i | LC-ESI-QTOF | ESI | 30 eV | [M+H]+ | positive | MS2 |
PM000927 | API 2000 | QqQ | ESI | 22 | [M+H]+ | positive | MS2 |
PR010172 | Pegasus III TOF-MS system, Lec... | GC-EI-TOF | - | - | - | positive | MS1 |
PR030003 | CE-system connected to 6210 Ti... | CE-ESI-TOF | ESI | - | [M+H]+ | positive | MS1 |
PS026701 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS026702 | TQD, Waters | Flow-injection QqQ/MS | ESI | 20 | [M+H]+ | positive | MS2 |
PS026703 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
RP001501 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
RP001502 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
RP001503 | maXis plus UHR-ToF-MS, Bruker ... | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
HMDB0000168_c_ms_1192 | maXis plus UHR-ToF-MS, Bruker ... | GC-MS | - | - | - | - | - |
HMDB0000168_c_ms_1254 | maXis plus UHR-ToF-MS, Bruker ... | GC-MS | - | - | - | - | - |
HMDB0000168_c_ms_1258 | maXis plus UHR-ToF-MS, Bruker ... | GC-MS | - | - | - | - | - |
HMDB0000168_c_ms_1289 | maXis plus UHR-ToF-MS, Bruker ... | GC-MS | - | - | - | - | - |
HMDB0000168_c_ms_1309 | maXis plus UHR-ToF-MS, Bruker ... | GC-MS | - | - | - | - | - |
HMDB0000168_c_ms_1338 | maXis plus UHR-ToF-MS, Bruker ... | GC-MS | - | - | - | - | - |
HMDB0000168_c_ms_1566 | maXis plus UHR-ToF-MS, Bruker ... | GC-MS | - | - | - | - | - |
MoNA002344 | GCMS-TQ8040 | GC-EI-QqQMS | - | - | - | - | - |