MoNA MS database records for Ureidopropionic acid
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MoNA017555 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M-H]- | negative | MS2 |
MoNA017556 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M-H]- | negative | MS2 |
MoNA019745 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 10 | [M+H]+ | positive | MS2 |
MoNA019746 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 20 | [M+H]+ | positive | MS2 |
MoNA019747 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 30 | [M+H]+ | positive | MS2 |
MoNA019748 | Agilent 6550 iFunnel | LC-ESI-QTOF | ESI | 40 | [M+H]+ | positive | MS2 |
MoNA024002 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M-H]- | negative | MS2 |
MoNA024011 | Thermo Scientific Orbitrap ID-... | LC-ESI-Orbitrap | ESI | HCD (NCE 40%) | [M+H]+ | positive | MS2 |
PS030601 | TQD, Waters | Flow-injection QqQ/MS | ESI | 10 | [M+H]+ | positive | MS2 |
PS030603 | TQD, Waters | Flow-injection QqQ/MS | ESI | 30 | [M+H]+ | positive | MS2 |
PS030605 | TQD, Waters | Flow-injection QqQ/MS | ESI | 50 | [M+H]+ | positive | MS2 |
MoNA018860 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA018863 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | - | [M+H]+ | positive | MS2 |
MoNA018861 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA018864 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 10 | [M+H]+ | positive | MS2 |
MoNA018862 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA018865 | Agilent 6550 iFunnel | LC-ESI-QTOF | - | 30 | [M+H]+ | positive | MS2 |
MoNA034206 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 10 eV | [M-H]- | negative | MS2 |
MoNA034204 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 20 eV | [M-H]- | negative | MS2 |
MoNA034207 | Agilent qTOF 6545 | LC-ESI-QTOF | - | 40 eV | [M-H]- | negative | MS2 |
FiehnLib000732 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
FiehnLib000733 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
CCMSLIB00005463995 | Orbitrap | - | - | - | [M-H]- | negative | MS2 |
CCMSLIB00005464003 | Orbitrap | - | - | - | [M+Na]+ | positive | MS2 |
CCMSLIB00000578026 | Q-Exactive Plus | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00005720760 | qTof | - | - | - | [M-H]- | negative | MS2 |
FiehnHILIC001674 | SCIEX TripleTOF 6600 | LC-ESI-QTOF | - | 35 eV | [M+H]+ | positive | MS2 |
MoNA037929 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M-H]- | negative | MS2 |
FiehnHILIC000091 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
EMBL-MCF_spec59992 | Thermo Q-Exactive Plus | LC-ESI-QFT | - | 35.0 eV | [M-H]- | negative | MS2 |
HMDB0062812_ms_ms_45 | Thermo Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | MS2 |
HMDB0062812_ms_ms_46 | Thermo Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | MS2 |
HMDB0062812_ms_ms_47 | Thermo Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | MS2 |
HMDB0000026_ms_ms_45 | Thermo Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | - |
HMDB0000026_ms_ms_46 | Thermo Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | - |
HMDB0000026_ms_ms_47 | Thermo Q-Exactive Plus | Quattro_QQQ | - | - | - | positive | - |
HMDB0000026_c_ms_1106 | Thermo Q-Exactive Plus | GC-MS | - | - | - | - | - |
HMDB0000026_c_ms_1271 | Thermo Q-Exactive Plus | GC-MS | - | - | - | - | - |
HMDB0000026_c_ms_1302 | Thermo Q-Exactive Plus | GC-MS | - | - | - | - | - |
HMDB0000026_c_ms_1334 | Thermo Q-Exactive Plus | GC-MS | - | - | - | - | - |
HMDB0062812_c_ms_1106 | Thermo Q-Exactive Plus | GC-MS | - | - | - | - | - |
HMDB0062812_c_ms_1271 | Thermo Q-Exactive Plus | GC-MS | - | - | - | - | - |
HMDB0062812_c_ms_1302 | Thermo Q-Exactive Plus | GC-MS | - | - | - | - | - |
HMDB0062812_c_ms_1334 | Thermo Q-Exactive Plus | GC-MS | - | - | - | - | - |