Summary of Study ST003104
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001927. The data can be accessed directly via it's Project DOI: 10.21228/M8N42X This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST003104 |
Study Title | Metabolomics studies on human cardiac samples |
Study Summary | Targeted metabolomics was performed to measure polar metabolites in both positive and negative ionization mode on left ventricular tissue acquired from pre-mortem healthy donor hearts as classified by formal pathological examination and stored at the Sydney Heart Bank. The minimum number of observations for young (age ≤ 25 years) and old (age ≥ 50 years) cohorts using liquid chromatography-tandem mass spectrometry (LC-MS/MS). |
Institute | University of Sydney |
Department | Medicine and Health |
Last Name | Koay |
First Name | Yen Chin |
Address | Charles Perkin Centre |
yen.koay@sydney.edu.au | |
Phone | +61486275851 |
Submit Date | 2023-09-10 |
Num Groups | 2 |
Total Subjects | 25 |
Num Males | 15 |
Num Females | 10 |
Raw Data Available | Yes |
Raw Data File Type(s) | mzML |
Analysis Type Detail | API |
Release Date | 2024-03-11 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN005082 | AN005083 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | HILIC |
Chromatography system | Agilent 1260 | Agilent 1260 |
Column | Waters Atlantis T3 (150 x 4.6mm,5um) | Waters XBridge BEH Amide (100 x 2.1mm,2.5um) |
MS Type | API | API |
MS instrument type | Triple quadrupole | Triple quadrupole |
MS instrument name | ABI Sciex 5500 QTrap | ABI Sciex 5500 QTrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | abundance | abundance |
MS:
MS ID: | MS004820 |
Analysis ID: | AN005082 |
Instrument Name: | ABI Sciex 5500 QTrap |
Instrument Type: | Triple quadrupole |
MS Type: | API |
MS Comments: | Targeted metabolite profiling was performed using MS multiple reaction-monitoring transitions. Multiple Reaction Monitoring (MRM) Q1/Q3 peak integration of the raw data files (Analyst software, v.1.6.2; ABSciex) was performed using software MultiQuant 3.0 (ABSciex). |
Ion Mode: | POSITIVE |
MS ID: | MS004821 |
Analysis ID: | AN005083 |
Instrument Name: | ABI Sciex 5500 QTrap |
Instrument Type: | Triple quadrupole |
MS Type: | API |
MS Comments: | Targeted metabolite profiling was performed using MS multiple reaction-monitoring transitions. Multiple Reaction Monitoring (MRM) Q1/Q3 peak integration of the raw data files (Analyst software, v.1.6.2; ABSciex) was performed using software MultiQuant 3.0 (ABSciex). |
Ion Mode: | NEGATIVE |