Return to study ST001155 main page

MB Sample ID: SA080282

Local Sample ID:NR1
Subject ID:SU001220
Subject Type:Plant
Subject Species:Phoenix dactylifera
Taxonomy ID:42345

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001220
Subject Type:Plant
Subject Species:Phoenix dactylifera
Taxonomy ID:42345

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
NR1SA080282FL012298NaCl-RootTreatment

Collection:

Collection ID:CO001214
Collection Summary:Leaf and root tissues were collected from date palm seedlings after treatment with NaCl and/or silicon, flash frozen with liquid nitrogen, and freeze dried.
Sample Type:Plant

Treatment:

Treatment ID:TR001235
Treatment Summary:Once the radicle of the seeds had emerged, they were then transferred to potting compost and maintained at 32C/30C with a photoperiod of 16/8 h in the growth chamber. The seedlings were then divided into four sets based on their treatments and were irrigated either with tap water with an electrical conductivity of 50 mS/m, considered as a control treatment (control), 300 mM NaCl without additional silicon for salt stress (NaCl), 5 mM Na2SiO3 (+Si) for silicon treatment or 5 mM of sodium silicate (Na2SiO3) along with 300 mM NaCl (NaCl+Si) for salt stress and silicon treatment. The NaCl and silicon treatments were administered on a weekly basis, as irrigation.

Sample Preparation:

Sampleprep ID:SP001228
Sampleprep Summary:A total of 24 samples were analyzed using LC-MS by HILIC chromatography on a 0.5 x 150 mm Zic-pHILIC column using 10 mM NH4HCO3 in water (A) and 10 mM NH4HCO3 in 95% acetonitrile (B) as solvents and by RPLC chromatography using the same solvents and a 0.5 x 100 mm PLRPS column. The Samples were extracted at a tissue concentration of 100 mg/mL (leaves) or 50 mg/mL (roots) in 80% methanol by vortexing for 10 minutes. The solids were collected by centrifugation, and then the supernatant was filtered through a 0.8 μm spin filter. Samples were injected onto the LC-MS and data was acquired in polarity switching mode with data dependent acquisition of MS/MS spectra.

Combined analysis:

Analysis ID AN001911 AN001912
Analysis type MS MS
Chromatography type HILIC Reversed phase
Chromatography system Thermo Q-Exactive Thermo Q-Exactive
Column Zic-pHILIC 0.5 x 150 mm 0.5 x 100 mm PLRPS column
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode UNSPECIFIED UNSPECIFIED
Units log10(peak area) log10(peak area)

Chromatography:

Chromatography ID:CH001384
Instrument Name:Thermo Q-Exactive
Column Name:Zic-pHILIC 0.5 x 150 mm
Chromatography Type:HILIC
  
Chromatography ID:CH001385
Instrument Name:Thermo Q-Exactive
Column Name:0.5 x 100 mm PLRPS column
Chromatography Type:Reversed phase

MS:

MS ID:MS001767
Analysis ID:AN001911
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Samples were injected onto the LC-MS and data was acquired in polarity switching mode with data dependent acquisition of MS/MS spectra. The ion mode is polarity-switching, which means it scans in positive and negative ion mode during the sample run, switching between the two modes about every 20 milliseconds.
Ion Mode:UNSPECIFIED
  
MS ID:MS001768
Analysis ID:AN001912
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Samples were injected onto the LC-MS and data was acquired in polarity switching mode with data dependent acquisition of MS/MS spectra. The ion mode is polarity-switching, which means it scans in positive and negative ion mode during the sample run, switching between the two modes about every 20 milliseconds.
Ion Mode:UNSPECIFIED
  logo