Return to study ST001157 main page
MB Sample ID: SA080323
Local Sample ID: | JHOP-05705 |
Subject ID: | SU001222 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Gender: | Male and female |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU001222 |
Subject Type: | Mammal |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Gender: | Male and female |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
JHOP-05705 | SA080323 | FL012310 | Plasma | Sample |
JHOP-05705 | SA080323 | FL012310 | Angiotensin II | TREATMENT |
Collection:
Collection ID: | CO001216 |
Collection Summary: | Plasma |
Collection Protocol Filename: | Sample_Collection-Feces_Pluznick.pdf |
Sample Type: | Blood (serum) |
Treatment:
Treatment ID: | TR001237 |
Treatment Summary: | Six week old C57BL/6 conventional (mice with gut microbiota; conv, n=6) and germ-free (mice without gut microbiota; GF, n=6) mice were infused with angiotensin-II (AngII) for 4 weeks (400ng.kg-1.min-1; Alzet 1004). In parallel control groups, conv (n=6) and GF (n=6) mice received saline via minipumps. |
Treatment Protocol Filename: | Treatment_Protocol__Pluznick.pdf |
Sample Preparation:
Sampleprep ID: | SP001230 |
Sampleprep Summary: | Samples were prepared using the automated MicroLab STARĀ® system from Hamilton Company. Several recovery standards were added prior to the first step in the extraction process for QC purposes. To remove protein, dissociate small molecules bound to protein or trapped in the precipitated protein matrix, and to recover chemically diverse metabolites, proteins were precipitated with methanol under vigorous shaking for 2 min (Glen Mills GenoGrinder 2000) followed by centrifugation. The resulting extract was divided into five fractions: two for analysis by two separate reverse phase (RP)/UPLC-MS/MS methods with positive ion mode electrospray ionization (ESI), one for analysis by RP/UPLC-MS/MS with negative ion mode ESI, one for analysis by HILIC/UPLC-MS/MS with negative ion mode ESI, and one sample was reserved for backup. Samples were placed briefly on a TurboVapĀ® (Zymark) to remove the organic solvent. The sample extracts were stored overnight under nitrogen before preparation for analysis. |
Combined analysis:
Analysis ID | AN001915 |
---|---|
Analysis type | MS |
Chromatography type | Reversed phase |
Chromatography system | Waters Acquity |
Column | Waters Acquity CSH C18 (100 x 2.1mm,1.7um) |
MS Type | ESI |
MS instrument type | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap |
Ion Mode | NEGATIVE |
Units | Peaks area |
Chromatography:
Chromatography ID: | CH001388 |
Methods Filename: | Ultrahigh_Performance_LC_Method_Pluznick.pdf |
Instrument Name: | Waters Acquity |
Column Name: | Waters Acquity CSH C18 (100 x 2.1mm,1.7um) |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS001771 |
Analysis ID: | AN001915 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | None |
Ion Mode: | NEGATIVE |