Return to study ST001741 main page

MB Sample ID: SA163126

Local Sample ID:200916_SCD_1_KO_in_vivo_PI_dil_1_20_L_dil_1_10_SMF_#52 - 200916_SCD_1_KO_F8_KO_n2
Subject ID:SU001818
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Genotype Strain:C57BL/6J
Age Or Age Range:6 weeks
Gender:Male
Animal Animal Supplier:Jackson Laboratory

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001818
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Genotype Strain:C57BL/6J
Age Or Age Range:6 weeks
Gender:Male
Animal Animal Supplier:Jackson Laboratory

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
200916_SCD_1_KO_in_vivo_PI_dil_1_20_L_dil_1_10_SMF_#52 - 200916_SCD_1_KO_F8_KO_n2SA163126FL019426Scd1ab-2JGenotype
200916_SCD_1_KO_in_vivo_PI_dil_1_20_L_dil_1_10_SMF_#52 - 200916_SCD_1_KO_F8_KO_n2SA163126FL019426FatTissue

Collection:

Collection ID:CO001811
Collection Summary:Mouse tissues were homogenized in PBS pH 7.4 for lipid extraction and UPLC-MS/MS analysis
Sample Type:Tissue
Storage Conditions:-80℃

Treatment:

Treatment ID:TR001831
Treatment Summary:Tissues from 6-week old male C57BL/6J mice (wildtype or homozygous for the Scd1ab-2J allele) were purchased from Jackson Laboratory.

Sample Preparation:

Sampleprep ID:SP001824
Sampleprep Summary:Phospholipids were extracted from tissue homogenates by successive addition of PBS pH 7.4, methanol, chloroform, and saline to a final ratio of 14:34:35:17. Evaporation of the organic layer yielded a lipid film that was dissolved in methanol and subjected to UPLC-MS/MS.
Extract Storage:-20℃

Combined analysis:

Analysis ID AN002834
Analysis type MS
Chromatography type Reversed phase
Chromatography system ExionLC
Column Waters Acquity BEH C8 (100 x 2.1mm,1.7um)
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name ABI Sciex Qtrap6500+
Ion Mode NEGATIVE
Units relative intensities

Chromatography:

Chromatography ID:CH002097
Chromatography Summary:Chromatographic separation of phospholipids was carried out on an Acquity BEH C8 column (1.7 μm, 2.1×100 mm, Waters, Milford, MA) using an ExionLC UHPLC.
Instrument Name:ExionLC
Column Name:Waters Acquity BEH C8 (100 x 2.1mm,1.7um)
Chromatography Type:Reversed phase

MS:

MS ID:MS002627
Analysis ID:AN002834
Instrument Name:ABI Sciex Qtrap6500+
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Targeted MRM with pre-optimized settings and subsequent automated integration of selected signals using Analyst 1.7 (Sciex).
Ion Mode:NEGATIVE