Return to study ST002136 main page

MB Sample ID: SA205245

Local Sample ID:2.5uM_run1
Subject ID:SU002221
Subject Type:Synthetic sample

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002221
Subject Type:Synthetic sample

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
2.5uM_run1SA205245FL025172standard mixfactor

Collection:

Collection ID:CO002214
Collection Summary:To improve CE peak shape and support electrophoretic focusing, a sample diluent consisting of 133 mM ammonium acetate, and 0.1% formic acid was prepared.13 This sample diluent was spiked with 1 µM 13C phenylalanine, 3 µM 13C6 arginine and 0.8 µM 13C methionine D3 as internal standards. Calibration mixtures were prepared from serial dilution of stock standard solutions using the spiked sample diluent in a 1:4 ratio. Each calibration standard was analyzed twice to yield calibration curves, calculate figures of merit, and perform metabolite quantification.
Sample Type:Synthetic Mixture

Treatment:

Treatment ID:TR002233
Treatment Summary:To improve CE peak shape and support electrophoretic focusing, a sample diluent consisting of 133 mM ammonium acetate, and 0.1% formic acid was prepared.13 This sample diluent was spiked with 1 µM 13C phenylalanine, 3 µM 13C6 arginine and 0.8 µM 13C methionine D3 as internal standards. Calibration mixtures were prepared from serial dilution of stock standard solutions using the spiked sample diluent in a 1:4 ratio. Each calibration standard was analyzed twice to yield calibration curves, calculate figures of merit, and perform metabolite quantification.

Sample Preparation:

Sampleprep ID:SP002227
Sampleprep Summary:To improve CE peak shape and support electrophoretic focusing, a sample diluent consisting of 133 mM ammonium acetate, and 0.1% formic acid was prepared.13 This sample diluent was spiked with 1 µM 13C phenylalanine, 3 µM 13C6 arginine and 0.8 µM 13C methionine D3 as internal standards. Calibration mixtures were prepared from serial dilution of stock standard solutions using the spiked sample diluent in a 1:4 ratio. Each calibration standard was analyzed twice to yield calibration curves, calculate figures of merit, and perform metabolite quantification.

Combined analysis:

Analysis ID AN003497
Analysis type MS
Chromatography type CE
Chromatography system ZipChip (908 Devices)
Column HS chip
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Exactive Plus Orbitrap
Ion Mode POSITIVE
Units Micromolars

Chromatography:

Chromatography ID:CH002583
Instrument Name:ZipChip (908 Devices)
Column Name:HS chip
Chromatography Type:CE

MS:

MS ID:MS003257
Analysis ID:AN003497
Instrument Name:Thermo Exactive Plus Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:All experiments were performed in positive ionization mode in the 50-500 m/z range at a mass resolution setting of 17,500. The capillary temperature was set to 200 °C and the sheath gas flow rate was 2 psi. The automatic gain control (AGC) target value was set to 3E6 and the maximum injection time was 20 ms. Data were acquired using Xcalibur 3.0 (Thermo Scientific) and were imported to Skyline software14 for peak picking and integration. The peak picking procedure used the analyte accurate m/z and migration time. Peak areas obtained from Skyline were exported as spreadsheets for further analysis. Quantitation was performed with the analyte peak areas relative to the peak area of one of the three isotopically labeled internal standards (13C6 arginine, 13C methionine D3 and 13C phenylalanine) chosen based on migration time similarities.
Ion Mode:POSITIVE