Return to study ST002331 main page

MB Sample ID: SA229994

Local Sample ID:VT_181030_M338_212
Subject ID:SU002418
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002418
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
VT_181030_M338_212SA229994FL029041ControlTreatment

Collection:

Collection ID:CO002411
Collection Summary:Individuals were enrolled in the PrecisionLink Biobank for Health Discovery at Boston Children’s Hospital (BCH) from January 2016 to November 2019. We collected 441 plasma samples from 230 females and 211 males with mean ages 15.7 and 14.3 years old, respectively (ranges from 4.8 months to 60.1 years). The International Classification of Diseases (versions 9 and 10) and SNOMED CT codes were collected for participants from the BCH Cerner electric health record database. To comply with the Health Insurance Portability and Accountability Act rules for protected health information, medical record identifier and personal information were removed from the EHR extracts and universal unique identifiers (UUIDs) were assigned to everyone. All analyses were performed with UUIDs, age at blood collection, gender information, and sample identifiers for plasma and DNA samples, which were provided by the BCH Biobank. The study was reviewed and approved by the BCH Institutional Review Board.
Sample Type:Blood (plasma)

Treatment:

Treatment ID:TR002430
Treatment Summary:Plasma samples in 50μL aliquot were mixed with acetonitrile containing 14 stable isotope internal standards at a 2:1 ratio to precipitate proteins. Samples were then equilibrated on ice for 30 minutes and centrifuged for 10 minutes at 13,400 rpm at 4°C. The supernatant was transferred to autosampler vials and kept in a refrigerated autosampler until analysis. Each extract was analyzed in triplicate using a dual column chromatography scheme that includes hydrophilic interaction liquid chromatography (HILIC; XBridge BEH Amide XP HILIC column; Waters, Waltham, MA, 50x2.1mm, 2.5μm) and reversed phase liquid chromatography (RPLC; C18 column; Higgins Analytical, Mountain View, CA, 50x2.1mm, 2.6 μm).

Sample Preparation:

Sampleprep ID:SP002424
Sampleprep Summary:Samples are prepared for metabolomics analysis using established methods (Johnson et al. (2010). Analyst; Go et al. (2015). Tox Sci). Prior to analysis, plasma aliquots were removed from storage at -80°C and thawed on ice. Each cryotube is then vortexed briefly to ensure homogeneity, and 50 μL transferred to a clean microfuge tube. Immediately after, the plasma is treated with 100 μL of ice-cold LC-MS grade acetonitrile (Sigma Aldrich) containing 2.5 μL of internal standard solution with eight stable isotopic chemicals selected to cover a range of chemical properties. Following addition of acetonitrile, plasma is then equilibrated for 30 min on ice, upon which precipitated proteins are removed by centrifuge (16.1 ×g at 4°C for 10 min). The resulting supernatant (100 μL) is removed, added to a low volume autosampler vial and maintained at 4°C until analysis (<22 h).
Sampleprep Protocol Filename:EmoryUniversity_HRM_sample_preparation_082016_01.pdf

Combined analysis:

Analysis ID AN003804 AN003805
Analysis type MS MS
Chromatography type HILIC Reversed phase
Chromatography system Dionex UltiMate 3000 Dionex UltiMate 3000
Column Waters XBridge BEH Amide XP HILIC (50 x 2.1mm,2.5um) Product #186006089; Thermo Accucore HILIC guard with holder,Product # 17526-012105 Higgins endcapped C18 stainless steel (50 x 2.1mm,3um),Product #TS-0521-C183; Thermo Accucore C18 guard with holder,Product #17126-014005
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid orbitrap Thermo Q Exactive HF hybrid orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak area peak area

Chromatography:

Chromatography ID:CH002814
Chromatography Summary:The HILIC column is operated parallel to reverse phase column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10- port and 6-port switching valves. During operation of HILIC separation method, the MS is operated in positive ion mode and 10 μL of sample is injected onto the HILIC column while the reverse phase column is flushing with wash solution. Flow rate is maintained at 0.35 mL/min until 1.5 min, increased to 0.4 mL/min at 4 min and held for 1 min. Solvent A is 100% LC-MS grade water, solvent B is 100% LC-MS grade acetonitrile and solvent C is 2% formic acid (v/v) in LC-MS grade water. Initial mobile phase conditions are 22.5% A, 75% B, 2.5% C hold for 1.5 min, with linear gradient to 77.5% A, 20% B, 2.5% C at 4 min, hold for 1 min, resulting in a total analytical run time of 5 min. During the flushing phase (reverse phase analytical separation), the HILIC column is equilibrated with a wash solution of 77.5% A, 20% B, 2.5% C.
Methods Filename:EmoryUniversity_HRM_QEHF_chromatography_5min_092017_v1.pdf
Instrument Name:Dionex UltiMate 3000
Column Name:Waters XBridge BEH Amide XP HILIC (50 x 2.1mm,2.5um) Product #186006089; Thermo Accucore HILIC guard with holder,Product # 17526-012105
Column Temperature:60
Solvent A:100% water
Solvent B:100% acetonitrile
Chromatography Type:HILIC
  
Chromatography ID:CH002815
Chromatography Summary:The C18 column is operated parallel to the HILIC column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10-port and 6- port switching valves. During operation of the C18 method, the MS is operated in negative ion mode and 10 μL of sample is injected onto the C18 column while the HILIC column is flushing with wash solution. Flow rate is maintained at 0.4 mL/min until 1.5 min, increased to 0.5 mL/min at 2 min and held for 3 min. Solvent A is 100% LC-MS grade water, solvent B is 100% LC-MS grade acetonitrile and solvent C is 10mM ammonium acetate in LC-MS grade water. Initial mobile phase conditions are 60% A, 35% B, 5% C hold for 0.5 min, with linear gradient to 0% A, 95% B, 5% C at 1.5 min, hold for 3.5 min, resulting in a total analytical run time of 5 min. During the flushing phase (HILIC analytical separation), the C18 column is equilibrated with a wash solution of 0% A, 95% B, 5% C until 2.5 min, followed by an equilibration solution of 60% A, 35% B, 5% C for 2.5 min.
Instrument Name:Dionex UltiMate 3000
Column Name:Higgins endcapped C18 stainless steel (50 x 2.1mm,3um),Product #TS-0521-C183; Thermo Accucore C18 guard with holder,Product #17126-014005
Column Temperature:60
Solvent A:100% water
Solvent B:100% acetonitrile
Chromatography Type:Reversed phase

MS:

MS ID:MS003546
Analysis ID:AN003804
Instrument Name:Thermo Q Exactive HF hybrid orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:no comment
Ion Mode:POSITIVE
Processing Parameters File:EmoryUniversity_HRM_DataAnalysis_MS_092017_v1.pdf
Analysis Protocol File:EmoryUniversity_HRM_QEHF_MassSpec_092017_v1.pdf
  
MS ID:MS003547
Analysis ID:AN003805
Instrument Name:Thermo Q Exactive HF hybrid orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:no comment
Ion Mode:NEGATIVE
Processing Parameters File:EmoryUniversity_HRM_DataAnalysis_MS_092017_v1.pdf
Analysis Protocol File:EmoryUniversity_HRM_QEHF_MassSpec_092017_v1.pdf
  logo