Return to study ST002345 main page

MB Sample ID: SA235375

Local Sample ID:Naive_248
Subject ID:SU002434
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Age Or Age Range:12-24 weeks
Gender:Male
Animal Animal Supplier:Jackson
Animal Light Cycle:12L/12D

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002434
Subject Type:Mammal
Subject Species:Mus musculus
Taxonomy ID:10090
Age Or Age Range:12-24 weeks
Gender:Male
Animal Animal Supplier:Jackson
Animal Light Cycle:12L/12D

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
Naive_248SA235375FL029196NaïveGroup

Collection:

Collection ID:CO002427
Collection Summary:Whole blood was extracted from animals at the time of euthanization from the heart chamber. Blood was collected into blood collection tubes (Fisher Scientific; #02-675-185) and spun for 10 min at 11,000g. Serum was collected and frozen in liquid nitrogen. 25uL of plasma was extracted with 500uL of acetonitrile by vortexing and centrifugation at 10min at 14,000rpm. 450uL of supernatant was transferred to new tube and dried via SpeedVac. Dried samples were reconstituted with 25uL of 50% methanol and transferred to autosampler vials. Injection volume =10uL in PRM mode for detection and quantification of 10 different analytes. Metabolite mixture was analyzed on Thermo Orbitrap IDX MS system coupled to a Vanquish UPLC system. Samples were transported via the autosampler (10uL injection volume) onto a Waters BEH C18 column. Runtime was 15min in PRM mode. Buffer A: 0.1% formic acid in water. Buffer B: 0.1% formic acid in methanol. LC Gradient: 0min: 0% B, 8min: 50% B, 9 min: 98% B, 13min: 98% B. Recalibration of system up to 15 min at 0% B for next injection.
Sample Type:Blood (serum)
Collection Method:Cardiac Puncture
Collection Location:Heart
Storage Conditions:Described in summary

Treatment:

Treatment ID:TR002446
Treatment Summary:Mice were subjected to 3weeks of unpredictable chronic mild restraint stress or kept in a naive setting

Sample Preparation:

Sampleprep ID:SP002440
Sampleprep Summary:Whole blood was extracted from animals at the time of euthanization from the heart chamber. Blood was collected into blood collection tubes (Fisher Scientific; #02-675-185) and spun for 10 min at 11,000g. Serum was collected and frozen in liquid nitrogen. 25uL of plasma was extracted with 500uL of acetonitrile by vortexing and centrifugation at 10min at 14,000rpm. 450uL of supernatant was transferred to new tube and dried via SpeedVac. Dried samples were reconstituted with 25uL of 50% methanol and transferred to autosampler vials. Injection volume =10uL in PRM mode for detection and quantification of 10 different analytes. Metabolite mixture was analyzed on Thermo Orbitrap IDX MS system coupled to a Vanquish UPLC system. Samples were transported via the autosampler (10uL injection volume) onto a Waters BEH C18 column. Runtime was 15min in PRM mode. Buffer A: 0.1% formic acid in water. Buffer B: 0.1% formic acid in methanol. LC Gradient: 0min: 0% B, 8min: 50% B, 9 min: 98% B, 13min: 98% B. Recalibration of system up to 15 min at 0% B for next injection.
Processing Storage Conditions:Described in summary
Extract Storage:Described in summary

Combined analysis:

Analysis ID AN003829
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Vanquish
Column Waters Acquity BEH C18 (100 x 2mm,1.7um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Orbitrap ID-X tribrid
Ion Mode UNSPECIFIED
Units ug/mL

Chromatography:

Chromatography ID:CH002834
Instrument Name:Thermo Vanquish
Column Name:Waters Acquity BEH C18 (100 x 2mm,1.7um)
Flow Gradient:0min: 0% B, 8min: 50% B, 9 min: 98% B, 13min: 98% B. Recalibration of system up to 15 min at 0% B for next injection.
Solvent A:100% water; 0.1% formic acid
Solvent B:100% methanol 0.1% formic acid
Analytical Time:15 min
Chromatography Type:Reversed phase

MS:

MS ID:MS003571
Analysis ID:AN003829
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Raw data files were brought into Skyline software. Targeted peak detection was done based on the parent mass. Mass analyzer set to Orbitrap and resolution power set to 120,000 resolution. Then all raw files and unknown samples were imported to Skyline. Calibration curves were generated by Linear regression fit. Targeted precursor MZ and MZ of analytes was used to track and quantification of the metabolite. Peak areas for analytes in samples were used for quantification based in the generated calibration curves.
Ion Mode:UNSPECIFIED
  logo