Return to study ST002386 main page

MB Sample ID: SA238028

Local Sample ID:PS5
Subject ID:SU002475
Subject Type:Fish
Subject Species:Scyliorhinus canicula

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002475
Subject Type:Fish
Subject Species:Scyliorhinus canicula

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
PS5SA238028FL029579wild-capturedGroup
PS5SA238028FL029579seminal plasmaSample

Collection:

Collection ID:CO002468
Collection Summary:Seminal plasma samples were collected and immediately snap frozen for metabolomics analysis at the end of experiment
Sample Type:Seminal plasma

Treatment:

Treatment ID:TR002487
Treatment Summary:Samples were collected from a total of 12 wild small-spotted catsharks from the Mediterranean Sea and 7 aquarium-housed small-spotted catsharks in collaboration with Oceanogràfic of Valencia. Location (wild vs. aquarium). Wild individuals were donated from local fisheries at the Valencian Community and were part of accidental captures intended to commercial fisheries ports at Valencia (39°26′45″N 0°19′12″O), Jávea (38°47′21″N 0°09′47″E) and Cullera port (39°09′58″N 0°15′10″O). Mediterranean Sea water parameters, measured by Valencia buoy (39º52′N0º20′E) were 14.6-19 °C temperature and 34-37 g/l salinity (http://www.puertos.es/es-es/oceanografia/Paginas/portus.aspx). Small-spotted catsharks under managed care were housed at Oceanogràfic of Valencia, Spain, in closed and recirculation system under controlled conditions, monitored water quality (17–21°C, 5.1 mg/l oxygen, 36 g/l salinity and 7.6–8.2 pH), fixed photoperiod (12:12 h) and disinfection using UV light and ozone.

Sample Preparation:

Sampleprep ID:SP002481
Sampleprep Summary:Seminal plasma were subjected to a comparative metabolomics analysis. For aquarium-housed individuals’ 7 samples of both types (Seminal plasma and peripheral blood plasma), were analysed to study the semi-polar and non-polar fractions. For wild-captured individuals’ 12 samples of both types (Seminal plasma and peripheral blood plasma), were analysed to study the semi-polar and non-polar fractions. For semi-polar analysis, metabolites were extracted from 100 μL of each Seminal plasma or peripheral blood plasma samples following a published method with a little modification (Y. Yu et al., 2021). Briefly, samples were dissolved in 200 μL of cold aqueous methanol (75 %), and 200 μL of acetronitrile (75 %), spiked with 10 μg/ml formononetin as internal standard. Then, the mixture was centrifugated at 20,000 xg for 15 min at 4 °C. The supernate (200 μL) was gained, and dried under low-temperature vacuum (Thermo Scientific, USA). The samples were redissolved resuspended with 100 μL of methanol (10 %) and transferred to HPLC tubes and an aliquot of 3 μL was injected for the analysis. For no-polar analysis, metabolites were extracted from 50 μL of each Seminal plasma or peripheral blood plasma samples following a published method with a little modification (Y. Yu et al., 2021). Briefly, samples were dissolved in 300 μL of cold aqueous methanol (100 %), spiked with 50 μg/ml alpha-tocopherol acetate as internal standard. Then, the mixture was swirled for 120 seconds, and 900 μL MTBE and 250 μL ultrapure water were added. After vortexed for 15 mins, the mixture was placed 30 min at 4 ℃. Then, the supernatants (900 μL) were gained, and dried under low-temperature vacuum (Thermo Scientific, USA). The samples were redissolved resuspended with 600 μL of acetonitrile–isopropanol mixture and transferred to HPLC tubes and an aliquot of 3 μL was injected for the analysis.

Combined analysis:

Analysis ID AN003887 AN003888
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Phenomenex Luna (100 x 2.1mm,2.5um) Phenomenex Luna (100 x 2.1mm,2.5um)
MS Type APCI APCI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units m/z ratio m/z ratio

Chromatography:

Chromatography ID:CH002880
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Phenomenex Luna (100 x 2.1mm,2.5um)
Chromatography Type:Reversed phase

MS:

MS ID:MS003627
Analysis ID:AN003887
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:APCI
MS Comments:For the untargeted metabolomic analysis, Compound Discoverer software (Thermofisher Scientific) was used to identify the peaks, peak filtration, and peak alignment, and performed chromatogram alignment, peak picking, and public database (e.g., ChemSpider, KEGG, Metabolika) querying based on accurate masses (m/z).
Ion Mode:POSITIVE
  
MS ID:MS003628
Analysis ID:AN003888
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:APCI
MS Comments:For the untargeted metabolomic analysis, Compound Discoverer software (Thermofisher Scientific) was used to identify the peaks, peak filtration, and peak alignment, and performed chromatogram alignment, peak picking, and public database (e.g., ChemSpider, KEGG, Metabolika) querying based on accurate masses (m/z).
Ion Mode:NEGATIVE
  logo