Return to study ST002353 main page

MB Sample ID: SA249786

Local Sample ID:MED1 Library 100 nM Input Sample 1
Subject ID:SU002593
Subject Type:Synthetic sample

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002593
Subject Type:Synthetic sample

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
MED1 Library 100 nM Input Sample 1SA249786FL031533100 nM librarymetabolite_source
MED1 Library 100 nM Input Sample 1SA249786FL031533MED1protein
MED1 Library 100 nM Input Sample 1SA249786FL031533150 nMRNA
MED1 Library 100 nM Input Sample 1SA249786FL031533inputfraction

Collection:

Collection ID:CO002586
Collection Summary:Chemical library to perform condensate metabolomics with a defined set of lipids. To analyze a defined set of lipids at known concentrations, the following molecules were purchased: phosphatidylcholine (3:0/3:0)(Cayman Chemical, 32703), phosphatidylcholine (9:0/9:0)(Cayman Chemical, 10009874), phosphatidylcholine (12:0/12:0)(Echelon Biosciences, L-1112), phosphatidylcholine (16:0/16:0)(Echelon Biosciences, L-1116), phosphatidylcholine (18:0/18:0)(Echelon Biosciences, L-1118), sn-glycero-3-phosphocholine, lysophosphatidylcholine (16:0)(Echelon Biosciences, L-1516), palmitic acid (Sigma Aldrich, P5585), phosphatidylethanolamine (16:0/16:0)(Avanti Polar Lipids, 850705), phosphatidylglycerol (16:0/16:0)(Avanti Polar Lipids, 840455), phosphatidylinositol (16:0/16:0)(Echelon Biosciences, P-0016), PIP2 (16:0/16:0)(Echelon Biosciences, P-4516), phosphatidylserine (16:0/16:0)(Echelon Biosciences, L-3116). These molecules were first dissolved in an appropriate organic solvent and then either 0.33 pmoles, 3.3 pmoles, or 33 pmoles of each molecule were combined in an eppendorf tube. The organic solvents were removed using a SpeedVac Concentrator (Savant, SPD131DDA) at 25oC and the dried chemical libraries were stored at -80oC. Each tube containing a chemical library was used to perform a single condensate metabolomics experiment. These libraries were initially re-suspended in condensate buffer (50 mM NH4HCO3 pH 7.5, 50 mM NaCl, 1 mM DTT). Molecules that were not fully soluble in condensate buffer were removed by centrifugation (2x5 min, 16,000 g each), in which only the supernatant was retained. Due to the lack of crowding agents, phase separation required greater concentrations of protein and RNA than typically employed for nucleocapsid and MED1 condensate formation17,32. Purified protein (37.5 μM) was centrifuged (1 min, 1,000 g) to disrupt any existing condensates and to remove any precipitated proteins. Purified protein (final concentration, 30 μM) was combined with metabolites (final concentration, 150 g/l protein equivalent) and then phage lambda RNA (final concentration, 0.15 μM) in a total volume of 300 µl. An input sample (10 µl) was saved and then the sample was allowed to incubate for 10 min at 25oC. Condensates were then separated from the aqueous environment by centrifugation (10 min, 12,500 g, 25oC). The aqueous phase was removed from the condensate phase and then equal volumes (usually ~ 2 µl) of the aqueous fraction, condensate fraction and input sample were processed for metabolomics using identical approaches as described below. First the samples were diluted in ammonium bicarbonate buffer (50 mM NH4HCO3 pH 7.5) and briefly heated (2 min, 65oC) to disrupt condensates before being added immediately to 4x volume of ice-cold 100% methanol to precipitate protein and RNA. Protein and RNA were separated from metabolites by vortexing the samples (2 min), followed by incubation at -25oC (10 min) and then centrifugation (5 min, 13,000 rpm). The supernatant was saved and the process was repeated on the pellet two more times after adding 200 µl of 80% methanol each time to the pellet. The three supernatants were combined and centrifuged (10 min, 14000 rpm) to remove any additional macromolecules. The final supernatant was collected and dried using a SpeedVac Concentrator run at 25oC.
Sample Type:Synthetic Mixture
Collection Method:80% methanol
Storage Conditions:-80℃

Treatment:

Treatment ID:TR002605
Treatment Summary:Chemical libraries were added with individual molecules at a concentration of 100 nM, 1 uM or 10 uM to the condensate-forming low-complexity domain MED1 tagged with mCherry. Condensates were stimulated with 150 nM RNA. Condensates were centrifuged to the bottom of a 600 ul tube. Equal fractions from the input sample, aqueous phase and condensate phases were collected separately. Metabolites were extracted from each fraction.

Sample Preparation:

Sampleprep ID:SP002599
Sampleprep Summary:Metabolites were extracted from each fraction and the input for LC-MS as follows. First the samples were diluted in ammonium bicarbonate buffer (50 mM NH4HCO3 pH 7.5) and briefly heated (2 min, 65oC) to disrupt condensates before being added immediately to 4x volume of ice-cold 100% methanol to precipitate protein and RNA. Protein and RNA were separated from metabolites by vortexing the samples (2 min), followed by incubation at -25oC (10 min) and then centrifugation (5 min, 13,000 rpm). The supernatant was saved and the process was repeated on the pellet two more times after adding 200 µl of 80% methanol each time to the pellet. The three supernatants were combined and centrifuged (10 min, 14000 rpm) to remove any additional macromolecules. The final supernatant was collected and dried using a SpeedVac Concentrator run at 25oC. On the day of metabolite analysis, dried-down extracts were reconstituted in 150 µl 70% acetonitrile, at a relative protein concentration of ~ 2 µg/µl, and 4 µl of this reconstituted extract was injected for LC/MS-based untargeted metabolite profiling.
Extract Storage:-80℃

Combined analysis:

Analysis ID AN004099 AN004100
Analysis type MS MS
Chromatography type Normal phase Normal phase
Chromatography system Agilent Model 1290 Infinity II liquid chromatography system Agilent Model 1290 Infinity II liquid chromatography system
Column Cogent Diamond Hydride (150 × 2.1 mm, 4um) Cogent Diamond Hydride (150 × 2.1 mm, 4um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6550 QTOF Agilent 6550 QTOF
Ion Mode POSITIVE NEGATIVE
Units Ion counts Ion counts

Chromatography:

Chromatography ID:CH003035
Chromatography Summary:Tissue extracts were analyzed by LC/MS as described previously, using a platform comprised of an Agilent Model 1290 Infinity II liquid chromatography system coupled to an Agilent 6550 iFunnel time-of-flight MS analyzer. Chromatography of metabolites utilized aqueous normal phase (ANP) chromatography on a Diamond Hydride column (Microsolv). Mobile phases consisted of: (A) 50% isopropanol, containing 0.025% acetic acid, and (B) 90% acetonitrile containing 5 mM ammonium acetate. To eliminate the interference of metal ions on chromatographic peak integrity and electrospray ionization, EDTA was added to the mobile phase at a final concentration of 5 µM. The following gradient was applied: 0-1.0 min, 99% B; 1.0-15.0 min, to 20% B; 15.0 to 29.0, 0% B; 29.1 to 37min, 99% B.
Instrument Name:Agilent Model 1290 Infinity II liquid chromatography system
Column Name:Cogent Diamond Hydride (150 × 2.1 mm, 4um)
Solvent A:50% isopropanol, containing 0.025% acetic acid
Solvent B:90% acetonitrile containing 5 mM ammonium acetate
Chromatography Type:Normal phase

MS:

MS ID:MS003846
Analysis ID:AN004099
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:LC/MS-based targeted and untargeted metabolite profiling. For targeted analysis, raw LC/MS data was extracted by MassProfinder 8.0 (Agilent Technologies) using an in-house annotated personal metabolite database that contains 863 metabolites (Agilent Technologies). Additionally, molecular feature extraction (MFE) was performed for untargeted metabolite profiling using MassProfinder 8.0 (Agilent Technologies). The untargeted molecular features were imported into MassProfiler Professional 15.1 (MPP, Agilent Technologies) and searched against Metlin personal metabolite database (PCDL database 8.0), Human Metabolome Database (HMDB) and an in-house phospholipid database for tentative metabolite ID assignments, based on monoisotopic neutral mass (< 5 ppm mass accuracy) matches. Furthermore, a molecular formula generator (MFG) algorithm in MPP was used to generate and score empirical molecular formulae, based on a weighted consideration of monoisotopic mass accuracy, isotope abundance ratios, and spacing between isotope peaks. A tentative compound ID was assigned when PCDL database and MFG scores concurred for a given candidate molecule. Tentatively assigned molecules were reextracted using Profinder 8.0 for confirmation of untargeted results. For phospholipids, assignment of IDs was based on the defined pattern of neutral loss and head group fragment ions. Metabolites from targeted and untargeted extraction were combined for further statistical analysis among groups of input, aqueous and condensate fractions. Metabolites were removed from our analysis if they had a low ion count or high variation in input samples. Measurements of metabolite ion counts in input samples should be replicates across experiments. As such, differences in metabolite ion counts reflect experimental variability. To determine appropriate cut-offs, we examined the relationship between metabolite ion counts and their variation across input sample technical replicates. Metabolites with a median of < 1000 ion counts/sample tended to have high variation across samples. As a result, these metabolites were removed. Metabolites were also removed with > 2.5 standard deviation in log2(ion counts) since the input measurements for these metabolites were particularly unreliable relative to what was observed for other metabolites.
Ion Mode:POSITIVE
  
MS ID:MS003847
Analysis ID:AN004100
Instrument Name:Agilent 6550 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:LC/MS-based targeted and untargeted metabolite profiling. For targeted analysis, raw LC/MS data was extracted by MassProfinder 8.0 (Agilent Technologies) using an in-house annotated personal metabolite database that contains 863 metabolites (Agilent Technologies). Additionally, molecular feature extraction (MFE) was performed for untargeted metabolite profiling using MassProfinder 8.0 (Agilent Technologies). The untargeted molecular features were imported into MassProfiler Professional 15.1 (MPP, Agilent Technologies) and searched against Metlin personal metabolite database (PCDL database 8.0), Human Metabolome Database (HMDB) and an in-house phospholipid database for tentative metabolite ID assignments, based on monoisotopic neutral mass (< 5 ppm mass accuracy) matches. Furthermore, a molecular formula generator (MFG) algorithm in MPP was used to generate and score empirical molecular formulae, based on a weighted consideration of monoisotopic mass accuracy, isotope abundance ratios, and spacing between isotope peaks. A tentative compound ID was assigned when PCDL database and MFG scores concurred for a given candidate molecule. Tentatively assigned molecules were reextracted using Profinder 8.0 for confirmation of untargeted results. For phospholipids, assignment of IDs was based on the defined pattern of neutral loss and head group fragment ions. Metabolites from targeted and untargeted extraction were combined for further statistical analysis among groups of input, aqueous and condensate fractions. Metabolites were removed from our analysis if they had a low ion count or high variation in input samples. Measurements of metabolite ion counts in input samples should be replicates across experiments. As such, differences in metabolite ion counts reflect experimental variability. To determine appropriate cut-offs, we examined the relationship between metabolite ion counts and their variation across input sample technical replicates. Metabolites with a median of < 1000 ion counts/sample tended to have high variation across samples. As a result, these metabolites were removed. Metabolites were also removed with > 2.5 standard deviation in log2(ion counts) since the input measurements for these metabolites were particularly unreliable relative to what was observed for other metabolites.
Ion Mode:NEGATIVE
  logo