Return to study ST002523 main page

MB Sample ID: SA254503

Local Sample ID:MK115
Subject ID:SU002623
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:68 (63, 73)
Weight Or Weight Range:77 (62, 87)
Height Or Height Range:170 (160, 176)
Gender:Male and female
Human Ethnicity:White
Human Medications:anti-PD-1 immune checkpoint inhibitors (nivolumab or pembrolizumab)
Human Inclusion Criteria:consecutive advanced cancer patients

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002623
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Age Or Age Range:68 (63, 73)
Weight Or Weight Range:77 (62, 87)
Height Or Height Range:170 (160, 176)
Gender:Male and female
Human Ethnicity:White
Human Medications:anti-PD-1 immune checkpoint inhibitors (nivolumab or pembrolizumab)
Human Inclusion Criteria:consecutive advanced cancer patients

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
MK115SA254503FL032603LowCandida
MK115SA254503FL032603FemaleGender
MK115SA254503FL032603NivolumabImmunotherapy

Collection:

Collection ID:CO002616
Collection Summary:Human urine samples were collected by from lung cancer patients and frozen at -80 °C. Samples were shipped to MS-OMICS for metabolomic analysis.
Sample Type:Urine
Storage Conditions:-80℃

Treatment:

Treatment ID:TR002635
Treatment Summary:To unfreeze samples at MS-OMICS, samples were assigned to their SpinX filters and centrifugated at 15,000 RPM for 5 minutes at 4 °C. Urine samples were then diluted 11 times in mobile phase eluent A and fortified with stable isotope labelled standards before analysis.
Treatment Compound:mobile phase eluent A

Sample Preparation:

Sampleprep ID:SP002629
Sampleprep Summary:Urine samples were then diluted 11 times in mobile phase eluent A and fortified with stable isotope labelled standards before analysis.

Combined analysis:

Analysis ID AN004157
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Vanquish
Column Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.8um)
MS Type ESI
MS instrument type QTRAP
MS instrument name Thermo Orbitrap Exploris 240
Ion Mode UNSPECIFIED
Units Peak area

Chromatography:

Chromatography ID:CH003076
Chromatography Summary:The samples were analysed with our semi-polar metabolites method, which is a slightly modified version of the protocol described by Catalin et al. (UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes, Water Application note 2011, 720004042en). The analysis was carried out in a randomised order using a UPLC system (Vanquish, Thermo Fisher Scientific) coupled with a high-resolution quadrupole-orbitrap mass spectrometer Orbitrap Exploris 240 MS, Thermo Fisher Scientific.
Instrument Name:Thermo Vanquish
Column Name:Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.8um)
Column Temperature:30
Flow Gradient:300 μL/min: 0-2 min: 0% B, 2-12 min: 35% B, 12-13 min: 90% B, 13-14 min: 90% B, 14-15 min: 0% B
Flow Rate:300 μL/min
Solvent A:100% water; 10 mM ammonium formate; 0.1% formic acid (pH 3.1)
Solvent B:100% methanol; 10 mM ammonium formate; 0.1% formic acid
Chromatography Type:Reversed phase

MS:

MS ID:MS003904
Analysis ID:AN004157
Instrument Name:Thermo Orbitrap Exploris 240
Instrument Type:QTRAP
MS Type:ESI
MS Comments:The ionization was achieved with an electrospray ionization interface operated in positive and negative ionization mode under polarity switching. Data were processed using Compound Discoverer 3.3 (Thermo Fisher Scientific) and Skyline 21.2.
Ion Mode:UNSPECIFIED