MB Sample ID: SA255620

Local Sample ID:hm4
Subject ID:SU002643
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606
Cell Strain Details:MDA-MB-231

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002643
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606
Cell Strain Details:MDA-MB-231

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
hm4SA255620FL032730MediaSample Type
hm4SA255620FL032730HypoxiaTreatment

Collection:

Collection ID:CO002636
Collection Summary:Cells were placed in static headspace chambers as previously described [4] with new, clean silicon gaskets. Low oxygen, hypoxic gas (1 % O2, 5 % CO2, 94 % N2; purchased from BOC Specialty Gases, Woking, UK) was flushed through the chambers at a rate of 4 L/min for 10 min (chamber volume = 25 L). Chambers were then closed and placed at 37 ˚C for 2 hours to allow residual oxygen in the media to equilibrate with chamber headspace. Chambers were then flushed again at a rate of 4 L/min for 10 min, sealed and returned to 37 ˚C. After a further 24 hours, chambers were flushed again at a rate of 4 L/min for 10 min. 15 ml of gas standards (MeCl, 520 ppb (parts per billion); MeBr, 22 ppb; MeI, 26 ppb; DMS, 110 ppb; CFC-11, 400 ppb and CH3Cl3, 110ppb; BOC Specialty Gases, Woking, UK) were then injected into the chambers through a butyl seal and time zero sample taken. Injected compounds are either known metabolites for cancer cells, or internal standards (CFC-11) for the analysis and quantification of metabolism. Final chamber concentrations were similar to environmental concentrations, e.g MeCl, 1.2 ppb and MeBr 0.05 ppb, particularly more polluted urban spaces (Redeker et al., 2007). Injected gases are the same as those used for calibration. Compounds not injected but detected at first time point, due to residual presence from laboratory air, (including isoprene, acetone, 2-MP, 3-MP and n-hexane) were quantified. Two time zero (T0) samples were taken using an evacuated 500 mL electropolished stainless steel canister (LabCommerce, San Jose, USA) through fine mesh Ascarite® traps (Archbold et al., 2005), after which the chamber was resealed and left on a platform rocker on its slowest setting for 120 min, at which point two further air samples (T1) were collected. Duplicate samples were taken so that two analytical approaches could be performed (targeted and non-untargeted MS). Cells were removed from the chamber, washed with PBS twice and lysed in 500 µL RIPA buffer (NaCl (5 M), 5 mL Tris-HCl (1 M, pH 8.0), 1 mL Nonidet P-40, 5 mL sodium deoxycholate (10 %), 1 mL SDS (10 %)) with protease inhibitor (Sigma-Aldrich, Roche; Mannheim, Germany). Protein concentration of lysates were determined using BCA assay (Thermo Scientific, Waltham, MA, USA). Media alone was treated exactly the same as cells, and only acetone was found to differ significantly between conditions (Supplementary figure 1). These media blank outcomes were subtracted from respective cellular samples prior to protein normalisation. Comparative controls include lab air blanks and those data available from the dataset and collection method published previously which created and quantified metabolic fluxes of volatile compounds from MDA-MB-231 under hyperoxic (lab air) conditions (Issitt et al., 2022a).
Sample Type:Cultured cells

Treatment:

Treatment ID:TR002655
Treatment Summary:Cells were placed in static headspace chambers as previously described [4] with new, clean silicon gaskets. Low oxygen, hypoxic gas (1 % O2, 5 % CO2, 94 % N2; purchased from BOC Specialty Gases, Woking, UK) was flushed through the chambers at a rate of 4 L/min for 10 min (chamber volume = 25 L). Chambers were then closed and placed at 37 ˚C for 2 hours to allow residual oxygen in the media to equilibrate with chamber headspace. Chambers were then flushed again at a rate of 4 L/min for 10 min, sealed and returned to 37 ˚C. After a further 24 hours, chambers were flushed again at a rate of 4 L/min for 10 min. 15 ml of gas standards (MeCl, 520 ppb (parts per billion); MeBr, 22 ppb; MeI, 26 ppb; DMS, 110 ppb; CFC-11, 400 ppb and CH3Cl3, 110ppb; BOC Specialty Gases, Woking, UK) were then injected into the chambers through a butyl seal and time zero sample taken. Injected compounds are either known metabolites for cancer cells, or internal standards (CFC-11) for the analysis and quantification of metabolism. Final chamber concentrations were similar to environmental concentrations, e.g MeCl, 1.2 ppb and MeBr 0.05 ppb, particularly more polluted urban spaces (Redeker et al., 2007). Injected gases are the same as those used for calibration. Compounds not injected but detected at first time point, due to residual presence from laboratory air, (including isoprene, acetone, 2-MP, 3-MP and n-hexane) were quantified. Two time zero (T0) samples were taken using an evacuated 500 mL electropolished stainless steel canister (LabCommerce, San Jose, USA) through fine mesh Ascarite® traps (Archbold et al., 2005), after which the chamber was resealed and left on a platform rocker on its slowest setting for 120 min, at which point two further air samples (T1) were collected. Duplicate samples were taken so that two analytical approaches could be performed (targeted and non-untargeted MS). Cells were removed from the chamber, washed with PBS twice and lysed in 500 µL RIPA buffer (NaCl (5 M), 5 mL Tris-HCl (1 M, pH 8.0), 1 mL Nonidet P-40, 5 mL sodium deoxycholate (10 %), 1 mL SDS (10 %)) with protease inhibitor (Sigma-Aldrich, Roche; Mannheim, Germany). Protein concentration of lysates were determined using BCA assay (Thermo Scientific, Waltham, MA, USA). Media alone was treated exactly the same as cells, and only acetone was found to differ significantly between conditions (Supplementary figure 1). These media blank outcomes were subtracted from respective cellular samples prior to protein normalisation. Comparative controls include lab air blanks and those data available from the dataset and collection method published previously which created and quantified metabolic fluxes of volatile compounds from MDA-MB-231 under hyperoxic (lab air) conditions (Issitt et al., 2022a).
Treatment:Hypoxia
Treatment Vehicle:Nitrogen
Cell Storage:37 degrees
Cell Media:DMEM
Cell Envir Cond:Hypoxia/lab air

Sample Preparation:

Sampleprep ID:SP002649
Sampleprep Summary:Collected canister samples were transferred to a liquid nitrogen trap through pressure differential. Pressure change between beginning and end of “injection” was measured, allowing calculation of the moles of canister collected air injected. Sample in the trap was then transferred, via heated helium flow, to an Aglient/HP 5972 MSD system (Santa Clara, CA, USA) equipped with a PoraBond Q column (25 m x 0.32 mm x 0.5 μm film thickness) (Restek©, Bellefonte, PN, USA). Targeted samples were analyzed in selected ion monitoring (SIM) mode, and untargeted samples in full scan (SCAN) mode with the mass range of 45-200 amu. The mass spectrometer was operated in electron impact ionization mode with 70 eV ionization energy, and transfer line, ion source, and quadrupole temperatures of 250, 280 and 280, respectively. For details on SIM and significantly altered, identified SCAN compounds, see Table 1. All samples were analysed within 6 days of collection. The oven program for both SIM and SCAN analyses were identical and are as follows: 35 ˚C for 2 min, 10 ˚C/min to 155 ˚C, 1 ˚C/min to 131 ˚C and 25 ˚C/min to 250 with a 5 min 30 second hold. Calibration was performed using standard gases (BOC Specialty Gases, Woking, UK). Linear regression of calibration curves confirmed strong, positive linear relationships between observed compound peak areas and moles of gas injected for each VOC (r2 > 0.9 in all cases). For compounds not purchased in gaseous state (BOC Specialty gases, as above), 1–2 mL of compound in liquid phase was injected neat into butyl sealed Wheaton-style glass vials (100 mL) and allowed to equilibrate for 1 h. 1 mL of headspace air was then removed from neat vial headspace using a gas tight syringe (Trajan, SGE) and injected into the headspace of a second 100 mL butyl sealed Wheaton-style glass vial. This was then repeated, and 1 mL of the 2nd serial dilution vial was injected into the GCMS system with 29 mL of lab air to give ppb concentrations. This was performed for methanethiol (MeSH (SPEXorganics, St Neots, UK)), isoprene (Alfa Aesar, Ward Hill, MA, USA), acetone (Sigma-Aldrich, Burlington, MA, USA), 2- & 3-methyl pentane and n-hexane (Thermo Scientific, Waltham, MA, USA). Reported compounds detected by the GC/-MS were confirmed by matching retention times and mass–charge (m/z) ratios with known standards.
Processing Storage Conditions:Room temperature

Combined analysis:

Analysis ID AN004190
Analysis type MS
Chromatography type GC
Chromatography system HP GCD 1800B
Column Agilent PoraBOND Q (25m x 0.32mm x 0.5um)
MS Type EI
MS instrument type Single quadrupole
MS instrument name Agilent/HP 5972 MSD
Ion Mode POSITIVE
Units pg/hr/ug and g/hr for media

Chromatography:

Chromatography ID:CH003104
Chromatography Summary:Collected canister samples were transferred to a liquid nitrogen trap through pressure differential. Pressure change between beginning and end of “injection” was measured, allowing calculation of the moles of canister collected air injected. Sample in the trap was then transferred, via heated helium flow, to an Aglient/HP 5972 MSD system (Santa Clara, CA, USA) equipped with a PoraBond Q column (25 m x 0.32 mm x 0.5 μm film thickness) (Restek©, Bellefonte, PN, USA). Targeted samples were analyzed in selected ion monitoring (SIM) mode, and untargeted samples in full scan (SCAN) mode with the mass range of 45-200 amu. The mass spectrometer was operated in electron impact ionization mode with 70 eV ionization energy, and transfer line, ion source, and quadrupole temperatures of 250, 280 and 280, respectively. For details on SIM and significantly altered, identified SCAN compounds, see Table 1. All samples were analysed within 6 days of collection. The oven program for both SIM and SCAN analyses were identical and are as follows: 35 ˚C for 2 min, 10 ˚C/min to 155 ˚C, 1 ˚C/min to 131 ˚C and 25 ˚C/min to 250 with a 5 min 30 second hold.
Instrument Name:HP GCD 1800B
Column Name:Agilent PoraBOND Q (25m x 0.32mm x 0.5um)
Column Temperature:250
Flow Gradient:NA
Flow Rate:10ml/min
Solvent A:NA
Solvent B:NA
Chromatography Type:GC

MS:

MS ID:MS003937
Analysis ID:AN004190
Instrument Name:Agilent/HP 5972 MSD
Instrument Type:Single quadrupole
MS Type:EI
MS Comments:Calibration was performed using standard gases (BOC Specialty Gases, Woking, UK). Linear regression of calibration curves confirmed strong, positive linear relationships between observed compound peak areas and moles of gas injected for each VOC (r2 > 0.9 in all cases). For compounds not purchased in gaseous state (BOC Specialty gases, as above), 1–2 mL of compound in liquid phase was injected neat into butyl sealed Wheaton-style glass vials (100 mL) and allowed to equilibrate for 1 h. 1 mL of headspace air was then removed from neat vial headspace using a gas tight syringe (Trajan, SGE) and injected into the headspace of a second 100 mL butyl sealed Wheaton-style glass vial. This was then repeated, and 1 mL of the 2nd serial dilution vial was injected into the GCMS system with 29 mL of lab air to give ppb concentrations. This was performed for methanethiol (MeSH (SPEXorganics, St Neots, UK)), isoprene (Alfa Aesar, Ward Hill, MA, USA), acetone (Sigma-Aldrich, Burlington, MA, USA), 2- & 3-methyl pentane and n-hexane (Thermo Scientific, Waltham, MA, USA). Reported compounds detected by the GC/-MS were confirmed by matching retention times and mass–charge (m/z) ratios with known standards. Equation 1: [VOC](ppt)=(CF x 〖10〗^12 x Peak area x Calibration slope)/n Equation 1 outlines the approach to calculating VOC concentrations in parts-per-trillion-by-volume, or pptv. Here Peak area refers to the combined peak areas for the mass-charge ratios identified in Table 1. Multiplying Peak areas by their associated calibration curves (Calibration Slope) generate molar amounts which, when divided by the number of moles of headspace air injected (n), generate a unitless (moles compound/moles of air) ratio. Pptv concentrations are then obtained by multiplying this unitless ratio by 1x1012. For clarity, part-per-billion-by-volume values would be obtained by multiplying the unitless ratios by 1x109, or one billion. Sample VOC concentrations were then normalised to CFC-11 concentrations (240 parts-per-trillion-by-volume (pptv)) through multiplication by a “correction factor”, or CF, Equation 1). CFC-11 was used as an internal standard, since atmospheric concentrations of CFC-11 are globally consistent and stable (Redeker et al., 2007). Quantification of Styrene was done as above but normalisation to CFC-11 was not possible under flushed, hypoxic conditions. NEGATIVE VALUES IN DATA SHOW CONSUMPTION OVER TIME. VARIATION IN SCALE BETWEEN MEDIA SAMPLES ARE DUE TO NORMALISATION OF CELLULAR DATA TO PROTEIN. AS DESCRIBED, MEDIA VALUES ARE SUBTRACTED FROM CELLULAR DATA PRIOR TO NORMALISATION AND EXPRESSED AS PG/HR/UG.
Ion Mode:POSITIVE