Return to study ST002792 main page
MB Sample ID: SA299554
Local Sample ID: | DMSO_iRBC_p_1 |
Subject ID: | SU002899 |
Subject Type: | Cultured cells |
Subject Species: | Plasmodium falciparum |
Taxonomy ID: | 5833 |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU002899 |
Subject Type: | Cultured cells |
Subject Species: | Plasmodium falciparum |
Taxonomy ID: | 5833 |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
DMSO_iRBC_p_1 | SA299554 | FL036377 | DMSO | treatment |
Collection:
Collection ID: | CO002892 |
Collection Summary: | Pf3D7 cultures underwent double sorbitol synchronization 14 h apart, followed by further incubation for 28-42 h to achieve the desired trophozoite stage (28 hpi) at 6% parasitaemia and 2% hematocrit. Infected RBCs (2x108) were treated with 10x the EC50 of MIPS2673 for 1 h, after which metabolites were extracted. During the drug incubation period parasites were at 37°C under a gas atmosphere of 94% N2, 5% CO2 and 1% O2. All samples were centrifuged at 650 g for 3 min, the supernatant was removed, and the pellet washed in 500 µL of ice-cold PBS. Samples were again centrifuged at 650 g for 3 min and pellets were resuspended in 150 µL of ice-cold extraction buffer (100% methanol) and quickly resuspended. The samples were then incubated on a vortex mixer for 1 h at 4°C before being centrifuged at 17,000 g for 10 min; from this 100 µL of supernatant was collected and stored at -80°C until analysis. For each sample, another 10 µL was collected and pooled, to serve as a quality control (QC) sample. |
Sample Type: | Blood (whole) |
Treatment:
Treatment ID: | TR002908 |
Treatment Summary: | Pf3D7 cultures underwent double sorbitol synchronization 14 h apart, followed by further incubation for 28-42 h to achieve the desired trophozoite stage (28 hpi) at 6% parasitaemia and 2% hematocrit. Infected RBCs (2x108) were treated with 10x the EC50 of MIPS2673 for 1 h, after which metabolites were extracted. During the drug incubation period parasites were at 37°C under a gas atmosphere of 94% N2, 5% CO2 and 1% O2. All samples were centrifuged at 650 g for 3 min, the supernatant was removed, and the pellet washed in 500 µL of ice-cold PBS. Samples were again centrifuged at 650 g for 3 min and pellets were resuspended in 150 µL of ice-cold extraction buffer (100% methanol) and quickly resuspended. The samples were then incubated on a vortex mixer for 1 h at 4°C before being centrifuged at 17,000 g for 10 min; from this 100 µL of supernatant was collected and stored at -80°C until analysis. For each sample, another 10 µL was collected and pooled, to serve as a quality control (QC) sample. |
Sample Preparation:
Sampleprep ID: | SP002905 |
Sampleprep Summary: | Pf3D7 cultures underwent double sorbitol synchronization 14 h apart, followed by further incubation for 28-42 h to achieve the desired trophozoite stage (28 hpi) at 6% parasitaemia and 2% hematocrit. Infected RBCs (2x108) were treated with 10x the EC50 of MIPS2673 for 1 h, after which metabolites were extracted. During the drug incubation period parasites were at 37°C under a gas atmosphere of 94% N2, 5% CO2 and 1% O2. All samples were centrifuged at 650 g for 3 min, the supernatant was removed, and the pellet washed in 500 µL of ice-cold PBS. Samples were again centrifuged at 650 g for 3 min and pellets were resuspended in 150 µL of ice-cold extraction buffer (100% methanol) and quickly resuspended. The samples were then incubated on a vortex mixer for 1 h at 4°C before being centrifuged at 17,000 g for 10 min; from this 100 µL of supernatant was collected and stored at -80°C until analysis. For each sample, another 10 µL was collected and pooled, to serve as a quality control (QC) sample. |
Combined analysis:
Analysis ID | AN004542 | AN004543 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | HILIC |
Chromatography system | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS |
Column | ZIC-pHILIC (150 x 4.6mm,5um) equipped with a guard (SeQuant,Merck) | ZIC-pHILIC (150 x 4.6mm,5um) equipped with a guard (SeQuant,Merck) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap | Thermo Q Exactive Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | peak height | peak height |
Chromatography:
Chromatography ID: | CH003412 |
Instrument Name: | Thermo Dionex Ultimate 3000 RS |
Column Name: | ZIC-pHILIC (150 x 4.6mm,5um) equipped with a guard (SeQuant,Merck) |
Column Temperature: | 25 |
Flow Gradient: | 0% B to 50% B over 15 min, then to 5% B at 18 min until 21 min, increasing to 80% B at 24 min until 32 min. |
Flow Rate: | 0.3 ml/min |
Solvent A: | 100% water; 20 mM ammonium carbonate |
Solvent B: | 100% acetonitrile |
Chromatography Type: | HILIC |
MS:
MS ID: | MS004289 |
Analysis ID: | AN004542 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Metabolite detection was performed using a high-resolution Q Exactive MS (ThermoFisher) in both positive and negative ionisation modes. The PBQC sample was run periodically throughout each LC-MS batch to monitor signal reproducibility and support downstream metabolite identification. Extraction solvent blank samples were also analysed to identify possible contaminating chemical species. To aid in metabolite identification, approximately 250 authentic metabolite standards were analysed prior to each LC-MS batch and their peaks and retention time manually checked using the ToxID software (ThermoFisher). Metabolomics data were analysed using the IDEOM workflow (Creek et al. 2012). Briefly, the IDEOM processing pipeline uses msconvert for conversion of raw files to mzXML files and split polarity, XCMS to extract raw peak intensities and mzMatch to align samples, filter noise, fill missing peaks and annotate related peaks. Manual assessment of spiked internal standards, total ion chromatograms and median peak heights ensured signal reproducibility and allowed exclusion of outlier samples. LC MS peak heights representing metabolite abundances were normalised by median peak height. High confidence metabolite identification (MSI level 1) was made by matching accurate mass and retention time to authentic metabolite standards. Putative identifications (MSI level 2) for metabolites lacking standards were based on exact mass and predicted retention times. |
Ion Mode: | POSITIVE |
MS ID: | MS004290 |
Analysis ID: | AN004543 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | Metabolite detection was performed using a high-resolution Q Exactive MS (ThermoFisher) in both positive and negative ionisation modes. The PBQC sample was run periodically throughout each LC-MS batch to monitor signal reproducibility and support downstream metabolite identification. Extraction solvent blank samples were also analysed to identify possible contaminating chemical species. To aid in metabolite identification, approximately 250 authentic metabolite standards were analysed prior to each LC-MS batch and their peaks and retention time manually checked using the ToxID software (ThermoFisher). Metabolomics data were analysed using the IDEOM workflow (Creek et al. 2012). Briefly, the IDEOM processing pipeline uses msconvert for conversion of raw files to mzXML files and split polarity, XCMS to extract raw peak intensities and mzMatch to align samples, filter noise, fill missing peaks and annotate related peaks. Manual assessment of spiked internal standards, total ion chromatograms and median peak heights ensured signal reproducibility and allowed exclusion of outlier samples. LC MS peak heights representing metabolite abundances were normalised by median peak height. High confidence metabolite identification (MSI level 1) was made by matching accurate mass and retention time to authentic metabolite standards. Putative identifications (MSI level 2) for metabolites lacking standards were based on exact mass and predicted retention times. |
Ion Mode: | NEGATIVE |