Return to study ST002988 main page
MB Sample ID: SA325697
Local Sample ID: | 78 |
Subject ID: | SU003101 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Age Or Age Range: | < 5 years old |
Gender: | Male and female |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU003101 |
Subject Type: | Human |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Age Or Age Range: | < 5 years old |
Gender: | Male and female |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
78 | SA325697 | FL038733 | 0 | IgE CMA |
78 | SA325697 | FL038733 | 0 | IgE other |
78 | SA325697 | FL038733 | 1 | non-IgE CMA |
78 | SA325697 | FL038733 | 0 | Healthy |
Collection:
Collection ID: | CO003094 |
Collection Summary: | Urine samples were collected using The Newcastle Urine Collector (SteriSets Medical Products, Guilhufe, Portugal) or directly in a plastic container. Samples were stored at -20 °C until pick-up (< 1 week). Following cooled transport (dry ice or icepacks). Urine samples were thawed and aliquoted upon arrival and stored at -80 °C awaiting analysis. |
Sample Type: | Urine |
Collection Method: | Spontaneous defecation |
Storage Conditions: | -80℃ |
Treatment:
Treatment ID: | TR003110 |
Treatment Summary: | No treatment was applied, patients were divided into 4 different control groups: - IgE-mediated cow's milk allergy - other functional gastrointestinal disorder - IgE-mediated other food allergy - healthy brothers and sisters |
Sample Preparation:
Sampleprep ID: | SP003107 |
Sampleprep Summary: | Extraction of the urinary metabolome was initiated by pipetting 300 mL urine into a 1.5-mL Eppendorf tube, after which 30 mL of ISTD mixture (100 ng mL&1 D-valine-d8 and of L-alanine-d3) was added. Following this, the sample was centrifuged for 8 min (1 000 x g, 4 %C). Next, 100 mL supernatant was collected and diluted (1:10) with ultrapure water, after which the resulting extract was transferred to a glass HPLC-vial. |
Processing Storage Conditions: | -80℃ |
Sample Spiking: | Internal standard |
Combined analysis:
Analysis ID | AN004908 |
---|---|
Analysis type | MS |
Chromatography type | Reversed phase |
Chromatography system | Thermo Dionex Ultimate 3000 |
Column | Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.8um) |
MS Type | ESI |
MS instrument type | Orbitrap |
MS instrument name | Thermo Q Exactive Orbitrap |
Ion Mode | UNSPECIFIED |
Units | a.u. |
Chromatography:
Chromatography ID: | CH003703 |
Instrument Name: | Thermo Dionex Ultimate 3000 |
Column Name: | Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.8um) |
Column Temperature: | 45 |
Flow Gradient: | A gradient profile with following proportions (v/v) of solvent A was applied: 0-1.5 min at 98%, 1.5-7.0 min from 98% to 75%, 7.0-8.0 min from 75% to 40%, 8.0-12.0 min from 40% to 5%, 12.0-14.0 min at 5%, 14.0-14.1 min from 5 to 98%, followed by 4.0 min of re-equilibration. |
Flow Rate: | 0.4 mL/min |
Internal Standard: | L-alanine-d3, D-valine-d8 |
Sample Injection: | 10 uL |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% acetonitrile; 0.1% formic acid |
Chromatography Type: | Reversed phase |
MS:
MS ID: | MS004651 |
Analysis ID: | AN004908 |
Instrument Name: | Thermo Q Exactive Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | MS acquisition: Xcalibur Targeted data processing: Xcalibur Untargeted data acquisition: Compound Discoverer, R studio Ion mode is unspecified as analysis is performed in polarity switching mode, thereby generating data for both positive and negative ionization at the same time. |
Ion Mode: | UNSPECIFIED |