Collection:

Collection ID:CO003182
Collection Summary:The presented study is on chemical standards
Sample Type:synthetic

Treatment:

Treatment ID:TR003198
Treatment Summary:no treatments were performed

Sample Preparation:

Sampleprep ID:SP003195
Sampleprep Summary:standards were solubilized in 50/50 methanol/water with 10uM ammonium hydroxide

Combined analysis:

Analysis ID AN005032
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Vanquish
Column Merck Supelco Ascentis Express C18 (150 x 2.1mm,2.7um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode POSITIVE
Units NA

Chromatography:

Chromatography ID:CH003803
Methods Filename:C18_LC_Conditions.pdf
Instrument Name:Thermo Vanquish
Column Name:Merck Supelco Ascentis Express C18 (150 x 2.1mm,2.7um)
Column Temperature:30
Flow Gradient:0–5 min: gradient was held at 5% B; 2–12.1 min: linear gradient of 5% to 95% B; 12.1–17.0 min: 95% B; 17.1–21.0 min: gradient was returned to 5% B
Flow Rate:0.25 ml/min
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:Reversed phase

MS:

MS ID:MS004771
Analysis ID:AN005032
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS data acquisition was performed using a Q Exactive Orbitrap benchtop orbitrap mass spectrometer equipped with an Ion Max source and a HESI II probe (Thermo Fisher Scientific, San Jose, CA, USA)in positive ionization mode and a PRM acquisition with the resolution set at 17,500, the AGC target at 2 × 10^5, and the maximum injection time (Max IT) at 40 msec. Collision energies were set at 20,40,60 and 80 NCE. Inclusion list was 651.7973 m/z for T3 and 777.6940 m/z for T4. HESI conditions were as follows: sheath gas flow rate: 40 units; Aug gas flow rate: 10 units; sweet gas flow rate: 0; spray voltage: 3.5 kV (pos), 2.8 kV (neg); capillary temperature: 380 °C; S-lens RF: 60; Aux gas heater temperature: 420 °C. MS spectra were consolidated using the mzVault software, automatically thresholded for noise and recalibrated for mass error.
Ion Mode:POSITIVE