Return to study ST003147 main page
MB Sample ID: SA340752
Local Sample ID: | Blank_NoFlow |
Subject ID: | SU003264 |
Subject Type: | Cultured cells |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Age Or Age Range: | 60 |
Gender: | Female |
Cell Biosource Or Supplier: | ATCC |
Cell Strain Details: | BT-474, breast cancer cell line |
Select appropriate tab below to view additional metadata details:
Subject:
Subject ID: | SU003264 |
Subject Type: | Cultured cells |
Subject Species: | Homo sapiens |
Taxonomy ID: | 9606 |
Age Or Age Range: | 60 |
Gender: | Female |
Cell Biosource Or Supplier: | ATCC |
Cell Strain Details: | BT-474, breast cancer cell line |
Factors:
Local Sample ID | MB Sample ID | Factor Level ID | Level Value | Factor Name |
---|---|---|---|---|
Blank_NoFlow | SA340752 | FL040303 | BT-474 | Sample source |
Blank_NoFlow | SA340752 | FL040303 | NA | [13C2] Acetate |
Blank_NoFlow | SA340752 | FL040303 | NA | Drug Treatment |
Collection:
Collection ID: | CO003257 |
Collection Summary: | One PBS washing, 80% methanol extraction. |
Collection Protocol Filename: | DM_metabolomics_samples.txt |
Sample Type: | Cultured cells |
Collection Method: | 80% methanol extraction |
Volumeoramount Collected: | 500 ul |
Storage Conditions: | -80℃ |
Collection Vials: | 1.5 ml plastic centrifuge tubes |
Storage Vials: | 1.5 ml plastic centrifuge tubes |
Treatment:
Treatment ID: | TR003273 |
Treatment Summary: | Cells were grown in RPMI-1640 supplemented with 200 uM [13C2] acetate and treated with 1 uM Fasnall or 1 uM GSK2194069. |
Treatment Compound: | Fasnall, GSK2194069 |
Treatment Dose: | 0 - 1 uM |
Treatment Doseduration: | 24 h |
Treatment Vehicle: | DMSO |
Cell Growth Container: | 6-well plates |
Cell Media: | RPMI-1640 |
Cell Envir Cond: | 37C, 5% CO2 |
Cell Pct Confluence: | ~70% |
Sample Preparation:
Sampleprep ID: | SP003271 |
Sampleprep Summary: | Metabolites were extracted with ice-cold 80% methanol. |
Sampleprep Protocol Filename: | DM_metabolomics_samples.txt |
Extraction Method: | 80% methanol |
Extract Enrichment: | None |
Extract Cleanup: | None |
Extract Storage: | -80℃ |
Sample Resuspension: | None |
Sample Derivatization: | None |
Sample Spiking: | None |
Subcellular Location: | Intracellular metabolites |
Combined analysis:
Analysis ID | AN005163 | AN005164 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | HILIC |
Chromatography system | Thermo Dionex Ultimate 3000 RS | Thermo Dionex Ultimate 3000 RS |
Column | Merck SeQuant ZIC-pHILIC (150 x 2.1mm,5um) | Merck SeQuant ZIC-pHILIC (150 x 2.1mm,5um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF-X Orbitrap | Thermo Q Exactive HF-X Orbitrap |
Ion Mode | NEGATIVE | POSITIVE |
Units | AU | AU |
Chromatography:
Chromatography ID: | CH003908 |
Instrument Name: | Thermo Dionex Ultimate 3000 RS |
Column Name: | Merck SeQuant ZIC-pHILIC (150 x 2.1mm,5um) |
Column Temperature: | 40 |
Flow Gradient: | A linear solvent gradient of a total duration 22.5 min was starting with 0.2 ml/min flow rate of 80% solvent B, 12.5 min – 30%, 15 min – 30%, 15.2 min – 80%, 20 min – 80%, 21 min – flow rate 0.3 ml/min, 22 min – flow rate 0.3 ml/min, 22.1 min – flow rate 0.2 ml/min. |
Flow Rate: | 0.2 ml/min |
Solvent A: | 100% Water; 0.01% ammonium hydroxide; 20 mM ammonium bicarbonate |
Solvent B: | 100% Acetonitrile |
Chromatography Type: | HILIC |
MS:
MS ID: | MS004899 |
Analysis ID: | AN005163 |
Instrument Name: | Thermo Q Exactive HF-X Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The HESI ion source voltage was set to the following parameters: 3,600 V in both polarity modes, sheath gas 30, auxiliary gas 5, spare gas 0, probe heater 200 °C, capillary temperature 325 °C, S-Lens RF level 65. The mass spectrometer was set to acquire data in the polarity-switching mode averaging two microscans with 60,000 resolution, automatic gain control (AGC) target 5e6, scan range 72-1080 m/z, and maximum orbitrap injection time (IT) 200 ms. Data were converted into the mzXML format by ProteoWizard and analyzed in MAVEN. |
Ion Mode: | NEGATIVE |
Ion Source Temperature: | 200 |
Ion Spray Voltage: | 3600 |
Ionization: | Both |
Source Temperature: | 200 |
Automatic Gain Control: | 5e6 |
Dataformat: | RAW |
MS ID: | MS004900 |
Analysis ID: | AN005164 |
Instrument Name: | Thermo Q Exactive HF-X Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The HESI ion source voltage was set to the following parameters: 3,600 V in both polarity modes, sheath gas 30, auxiliary gas 5, spare gas 0, probe heater 200 °C, capillary temperature 325 °C, S-Lens RF level 65. The mass spectrometer was set to acquire data in the polarity-switching mode averaging two microscans with 60,000 resolution, automatic gain control (AGC) target 5e6, scan range 72-1080 m/z, and maximum orbitrap injection time (IT) 200 ms. Data were converted into the mzXML format by ProteoWizard and analyzed in MAVEN. |
Ion Mode: | POSITIVE |
Ion Source Temperature: | 200 |
Ion Spray Voltage: | 3600 |
Ionization: | Both |
Source Temperature: | 200 |
Automatic Gain Control: | 5e6 |
Dataformat: | RAW |