MB Sample ID: SA342138

Local Sample ID:VT_200807_M394_224
Subject ID:SU003277
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU003277
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606
Gender:Male and female

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
VT_200807_M394_224SA342138FL040425PDFactor
VT_200807_M394_224SA342138FL040425SerumSample source

Collection:

Collection ID:CO003270
Collection Summary:Blood samples were drawn from participants during field visits. Samples were centrifuged, kept on dry ice, and then stored in a −80 °C freezer at UCLA. Serum samples were shipped frozen to Emory University on dry ice for metabolomics analyses, where they were stored at −80 °C until LC-MS processing.
Sample Type:Blood (serum)

Treatment:

Treatment ID:TR003286
Treatment Summary:Samples are from participants of the PEG study, which is a population-based Parkinson's disease case-control study from Central California

Sample Preparation:

Sampleprep ID:SP003284
Sampleprep Summary:Blood samples were drawn from participants during field visits. Samples were centrifuged, kept on dry ice, and then stored in a −80 °C freezer at UCLA. Serum samples were shipped frozen to Emory University on dry ice for metabolomics analyses, where they were stored at −80 °C until LC-MS analysis. High-Resolution Metabolomics (HRM) was conducted according to established methods at Emory University (Clincal Biomarkers Laboratory). See the attached SOP protocol. Methods related to the PEG study population and data processing are found in Study_Methods.pdf
Sampleprep Protocol Filename:EmoryUniversity_HRM_SP_082016_01.pdf

Combined analysis:

Analysis ID AN005181 AN005182
Analysis type MS MS
Chromatography type HILIC Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Waters XBridge BEH Amide (50 x 2.1mm,2.5um) Thermo Higgins C18 (50 x 2.1mm,3um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units log2 transformed intensity log2 transformed intensity

Chromatography:

Chromatography ID:CH003919
Chromatography Summary:The HILIC column is operated parallel to reverse phase column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10-port and 6-port switching valves. During operation of HILIC separation method, the MS is operated in positive ion mode and 10 microliters of sample is injected onto the HILIC column while the reverse phase column is flushing with wash solution. Flow rate is maintained at 0.35 mL/min until 1.5 min, increased to 0.4 mL/min at 4 min and held for 1 min. Solvent A is 100% LC-MS grade water, solvent B is 100% LC-MS grade acetonitrile and solvent C is 2% formic acid (v/v) in LC-MS grade water. Initial mobile phase conditions are 22.5% A, 75% B, 2.5% C hold for 1.5 min, with linear gradient to 77.5% A, 20% B, 2.5% C at 4 min, hold for 1 min, resulting in a total analytical run time of 5 min. During the flushing phase (reverse phase analytical separation), the HILIC column is equilibrated with a wash solution of 77.5% A, 20% B, 2.5% C.
Methods Filename:EmoryUniversity_HRM-QEHF_chromatography_5min_092017_v1.pdf
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Waters XBridge BEH Amide (50 x 2.1mm,2.5um)
Column Temperature:60
Flow Gradient:22.5% A, 75% B, 2.5% C hold for 1.5 min, linear gradient to 77.5% A, 20% B, 2.5% C at 4 min, hold for 1 min
Flow Rate:0.35 mL/min for 1.5 min; linear increase to 0.4 mL/min at 4 min, hold for 1 mi
Sample Injection:10 uL
Solvent A:100% water
Solvent B:100% acetonitrile
Analytical Time:5 min
Chromatography Type:HILIC
Solvent C:98% water/2% formic acid
  
Chromatography ID:CH003920
Chromatography Summary:The C18 column is operated parallel to the HILIC column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10-port and 6- port switching valves. During operation of the C18 method, the MS is operated in negative ion mode and 10 μL of sample is injected onto the C18 column while the HILIC column is flushing with wash solution. Flow rate is maintained at 0.4 mL/min until 1.5 min, increased to 0.5 mL/min at 2 min and held for 3 min. Solvent A is 100% LC-MS grade water, solvent B is 100% LC-MS grade acetonitrile and solvent C is 10mM ammonium acetate in LC-MS grade water. Initial mmobile phase conditions are 60% A, 35% B, 5% C hold for 0.5 min, with linear gradient to 0% A, 95% B, 5% C at 1.5 min, hold for 3.5 min, resulting in a total analytical run time of 5 min. During the flushing phase (HILIC analytical separation), the C18 column is equilibrated with a wash solution of 0% A, 95% B, 5% C until 2.5 min, followed by an equilibration solution of 60% A, 35% B, 5% C for 2.5 min.
Methods Filename:EmoryUniversity_HRM-QEHF_chromatography_5min_092017_v1.pdf
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Thermo Higgins C18 (50 x 2.1mm,3um)
Column Temperature:60
Flow Gradient:60% A, 35% B, 5% C hold for 0.5 min, linear gradient to 0% A, 95% B, 5% C at 1.5 min, hold for 3 min
Flow Rate:0.4 mL/min for 1.5 min; linear increase to 0.5 mL/min at 2 min held for 3 min
Sample Injection:10 uL
Solvent A:100% water
Solvent B:100% acetonitrile
Analytical Time:5 min
Chromatography Type:Reversed phase
Solvent C:100% water; 10mM ammonium acetate

MS:

MS ID:MS004914
Analysis ID:AN005181
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:See attached files
Ion Mode:POSITIVE
Capillary Temperature:250C
Collision Gas:N2
Dry Gas Flow:45
Dry Gas Temp:150C
Mass Accuracy:< 3ppm
Spray Voltage:3500
Activation Parameter:5.00E+05
Activation Time:118ms
Interface Voltage:S-Lens RF level= 55
Acquisition Parameters File:EmoryUniversity_HRM_QEHF-MassSpec_092017_v1.pdf
Processing Parameters File:EmoryUniversity_SOP_DataAnalysis_092017_v1.pdf
Analysis Protocol File:Study_Methods.pdf
  
MS ID:MS004915
Analysis ID:AN005182
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:See attached files
Ion Mode:NEGATIVE
Capillary Temperature:250C
Collision Gas:N2
Dry Gas Flow:45
Dry Gas Temp:150C
Mass Accuracy:< 3ppm
Spray Voltage:-4000
Activation Parameter:5.00E+05
Activation Time:118ms
Interface Voltage:S-Lens RF level= 55
Acquisition Parameters File:EmoryUniversity_HRM_QEHF-MassSpec_092017_v1.pdf
Processing Parameters File:EmoryUniversity_SOP_DataAnalysis_092017_v1.pdf
Analysis Protocol File:Study_Methods.pdf