Return to study ST003162 main page

MB Sample ID: SA342890

Local Sample ID:WL_RPLC_POS_WT_3
Subject ID:SU003281
Subject Type:Insect
Subject Species:Drosophila melanogaster
Taxonomy ID:7227

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU003281
Subject Type:Insect
Subject Species:Drosophila melanogaster
Taxonomy ID:7227

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
WL_RPLC_POS_WT_3SA342890FL040443Wild-typeGenotype
WL_RPLC_POS_WT_3SA342890FL040443Whole LarvaeSample source

Collection:

Collection ID:CO003274
Collection Summary:Whole larvae and dissected CNS
Sample Type:Larvae, CNS

Treatment:

Treatment ID:TR003290
Treatment Summary:Untargeted lipidomics analysis was conducted on whole larva and dissected CNS of wild type and ifc-/- mutants at the late-third instar stage. Five replicates were prepared for each set of experiments. For whole larvae, at least 15 larvae of each genotype were used for each replicate. For the dissected CNS, at least 50 wild type and 60 ifc-/- CNS were used per replicate. Immediately following collection or dissection, larvae and the dissected CNS were flash frozen in liquid nitrogen and placed at -80°C.

Sample Preparation:

Sampleprep ID:SP003288
Sampleprep Summary:Whole larvae and CNS samples were extracted utilizing a tissue homogenizer, employing a solvent mixture of acetonitrile, methanol, and water in a 2:2:1 ratio, using 40 µL per mg of wet weight. The samples were then stored at -20°C overnight. Following centrifugation at 14,000 x g for 10 minutes at 4°C, the supernatant was transferred into an LC/MS vial and subsequently stored at -80°C until LC/MS analysis.

Combined analysis:

Analysis ID AN005187 AN005188 AN005189 AN005190
Analysis type MS MS MS MS
Chromatography type HILIC HILIC Reversed phase Reversed phase
Chromatography system Thermo Vanquish Flex UHPLC Systems Thermo Vanquish Flex UHPLC Systems Agilent 1290 Infinity II Agilent 1290 Infinity II
Column HILICON iHILIC-(P) Classic (100 x 2.1mm,5um) HILICON iHILIC-(P) Classic (100 x 2.1mm,5um) Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.7um) Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap QTOF Orbitrap
MS instrument name Thermo Orbitrap ID-X tribrid Thermo Orbitrap ID-X tribrid Agilent 6545 QTOF Thermo Orbitrap ID-X tribrid
Ion Mode NEGATIVE NEGATIVE POSITIVE POSITIVE
Units peak area peak area peak area peak area

Chromatography:

Chromatography ID:CH003924
Instrument Name:Thermo Vanquish Flex UHPLC Systems
Column Name:HILICON iHILIC-(P) Classic (100 x 2.1mm,5um)
Column Temperature:45
Flow Gradient:0–1 min: 90% B, 1–12 min: 90-35% B, 12–12.5 min: 35-25% B, 12.5–14.5 min: 25% B
Flow Rate:250 uL/min
Solvent A:water/acetonitrile (95/5); 20 mM ammonium bicarbonate; 0.1% ammonium hydroxide; 2.5 μM medronic acid
Solvent B:acetonitrile/water (95/5)
Chromatography Type:HILIC
  
Chromatography ID:CH003925
Instrument Name:Agilent 1290 Infinity II
Column Name:Waters ACQUITY UPLC HSS T3 (150 x 2.1mm,1.7um)
Column Temperature:60
Flow Gradient:0-2min: 30% B, 2-17 min: 30%-75% B, 17-20 min: 75%-85% B, 20-23 min: 85%-100% B, 23-26 min: 100% B
Flow Rate:250 uL/min
Solvent A:acetronitrile/water (60/40); 10mM ammonium formate; 2.5 uM medronic acid; 0.1% formic acid
Solvent B:2-propanol/acetonitrile (90/10); 10mM ammonium formate; 0.1% formic acid
Chromatography Type:Reversed phase

MS:

MS ID:MS004920
Analysis ID:AN005187
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were collected with the following MS source settings: spray voltage, -2.8 kV; sheath gas, 50; auxiliary gas, 10; sweep gas, 1; ion transfer tube temperature, 300°C; vaporizer temperature, 200°C; mass range, 67 – 1000 Da; resolution, 120,000; maximum injection time, 200 ms; isolation window, 1.6 Da. XCMS and Skyline software were used for data processing
Ion Mode:NEGATIVE
  
MS ID:MS004921
Analysis ID:AN005188
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were collected with the following MS source settings: spray voltage, -2.8 kV; sheath gas, 50; auxiliary gas, 10; sweep gas, 1; ion transfer tube temperature, 300°C; vaporizer temperature, 200°C; mass range, 67 – 1000 Da; resolution, 120,000; maximum injection time, 200 ms; isolation window, 1.6 Da. XCMS and Skyline software were used for data processing
Ion Mode:NEGATIVE
  
MS ID:MS004922
Analysis ID:AN005189
Instrument Name:Agilent 6545 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Data were collected with the following MS source settings: gas temp, 250°C; drying gas, 11 l/min; nebulizer, 35 psi; sheath gas temp, 300°C; sheath gas flow 12 l/min; capillary voltage, 3 kV; nozzle voltage, 500 V; isolation window, 1.3 Da. XCMS and Skyline software were used for data processing
Ion Mode:POSITIVE
  
MS ID:MS004923
Analysis ID:AN005190
Instrument Name:Thermo Orbitrap ID-X tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were collected with the following MS source settings: spray voltage, -3 kV; sheath gas, 50; auxiliary gas, 10; sweep gas, 1; ion transfer tube temperature, 300°C; vaporizer temperature, 350°C; mass range, 100 – 1500 Da; resolution, 120,000; maximum injection time, 150 ms; isolation window, 1.6 Da. XCMS and Skyline software were used for data processing
Ion Mode:POSITIVE
  logo