Return to study ST003177 main page

MB Sample ID: SA344420

Local Sample ID:POS_107
Subject ID:SU003296
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU003296
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
POS_107SA344420FL040581RA-followClinical group
POS_107SA344420FL040581bloodSample source

Collection:

Collection ID:CO003289
Collection Summary:The study collected plasma samples from all participants at West China Hospital, Sichuan University. These were approved by the Research Ethics Committee of West China Hospital, Sichuan University (Permission number: 2021(790)), and informed consent was obtained from all participants. Patients were diagnosed with RA according to the 2010 American College of Rheumatology (ACR)/European League Against Rheumatism (EULAR) criteria. The healthy control group consisted of individuals matched in age and gender, with no history or clinical evidence of autoimmune or rheumatic diseases. Blood collection followed standard venipuncture procedures using anticoagulant tubes. Plasma samples were obtained after centrifugation and stored at -80°C. ACPA levels were measured using Elecsys anti-CCP detection on the Cobas® e 801 module (Roche Diagnostics, Mannheim, Germany), with results categorized as positive (≥17.0 U/ml) or negative (<17.0 U/ml).
Sample Type:Blood (plasma)

Treatment:

Treatment ID:TR003305
Treatment Summary:A subset of RA patients were followed-up for three months after treatment with MTX monotherapy or a combination of csDMARDs. During this period, clinical data and blood specimens were gathered at the conclusion.

Sample Preparation:

Sampleprep ID:SP003303
Sampleprep Summary:The plasma samples were thawed by transferring them from -80°C to a 4°C refrigerator. Then, take out 50 μL of the plasma sample into another tube after vortex mixing and added to 250 μL of pre-cooled Spike MeOH containing isotopic chemicals (120.89 μM 13C6-D-glucose, 23.12 mM 13C5-L-glutamate-15N). The mixture was thoroughly mixed by vortexing at 1500 rpm for 2 minutes at 4°C. The mixture was then placed in a -20°C refrigerator and allowed to stand for 30 minutes. Afterward, ultrasonication was performed in an ice-water bath for 10 minutes. Following ultrasonication, the mixture was centrifuged at 13,000 rpm for 20 minutes at 4°C. 20 μL of each sample from every batch was extracted from the tube and mixed for QC analysis using mass spectrometry (MS). The 150ul remaining extract was concentrated, vacuum dried, and stored at -80°C.

Combined analysis:

Analysis ID AN005215 AN005216
Analysis type MS MS
Chromatography type HILIC HILIC
Chromatography system SCIEX ExionLC UHPLC SCIEX ExionLC UHPLC
Column Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Triple quadrupole Triple quadrupole
MS instrument name ABI SCIEX Triple Quad 5500+ LC-MS/MS ABI SCIEX Triple Quad 5500+ LC-MS/MS
Ion Mode POSITIVE NEGATIVE
Units peak area Peak area

Chromatography:

Chromatography ID:CH003944
Chromatography Summary:SCIEX ExionLC UHPLC system coupled with a SCIEX Triple Quad 5500+ LC-MS/MS
Instrument Name:SCIEX ExionLC UHPLC
Column Name:Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um)
Column Temperature:40°C
Flow Gradient:1.5 min, 90% B; 5 min, 45% B; 10 min, 45% B; 12 min, 90% B; 25 min, 90% B
Flow Rate:0.3 mL/min
Solvent A:90% water/10% acetonitrile; 10 mM ammonium acetate; 0.2% acetic acid
Solvent B:90% acetonitrile/10% water; 10 mM ammonium acetate; 0.2% acetic acid
Chromatography Type:HILIC

MS:

MS ID:MS004948
Analysis ID:AN005215
Instrument Name:ABI SCIEX Triple Quad 5500+ LC-MS/MS
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Within each batch, normalization was performed by dividing the level of each metabolite by the average value of the first and last QC samples in that batch. Subsequently, a cross-sample total sum correction was conducted for all metabolites. Then, the data was mean-centered and divided by the standard deviation of each variable for standardization. Finally, a log10 transformation was applied to the data. We further removed metabolites with a coefficient of variation (CV) greater than 0.35 and any metabolites with more than 50% missing values within any group (RA, at-risk of RA, and Health). For analyses intolerant to missing data, any missing values are substituted with 1/5 of the minimum positive value of their corresponding variables.
Ion Mode:POSITIVE
  
MS ID:MS004949
Analysis ID:AN005216
Instrument Name:ABI SCIEX Triple Quad 5500+ LC-MS/MS
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:Within each batch, normalization was performed by dividing the level of each metabolite by the average value of the first and last QC samples in that batch. Subsequently, a cross-sample total sum correction was conducted for all metabolites. Then, the data was mean-centered and divided by the standard deviation of each variable for standardization. Finally, a log10 transformation was applied to the data. We further removed metabolites with a coefficient of variation (CV) greater than 0.35 and any metabolites with more than 50% missing values within any group (RA, at-risk of RA, and Health). For analyses intolerant to missing data, any missing values are substituted with 1/5 of the minimum positive value of their corresponding variables.
Ion Mode:NEGATIVE
  logo