Return to study ST003245 main page

MB Sample ID: SA353448

Local Sample ID:190905_AG_Brabletz_ZEB1_EMT_Lipidomics__shGFP_#4_1
Subject ID:SU003364
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU003364
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
190905_AG_Brabletz_ZEB1_EMT_Lipidomics__shGFP_#4_1SA353448FL041191Breast cancer cell lineSample source
190905_AG_Brabletz_ZEB1_EMT_Lipidomics__shGFP_#4_1SA353448FL041191control for Zeb1 stable knockdownGenotype

Collection:

Collection ID:CO003357
Collection Summary:Cultured cells were washed, trypsinized, counted and flash-frozen in liquid N2 and stored at -80°C.
Sample Type:Breast cancer cells
Storage Conditions:-80℃

Treatment:

Treatment ID:TR003373
Treatment Summary:Human breast cancer MDA-MB-231 wildtype (WT) cells and the stably transduced MDA-MB-231 shZeb1 (stable Zeb1 knockdown) and shCtrl cell lines (control cell line for the stable Zeb1 knockdown) (Spaderna et al. 2008, DOI: 10.1158/0008-5472.CAN-07-5682) were collected, snap-frozen and stored at -80°C.

Sample Preparation:

Sampleprep ID:SP003371
Sampleprep Summary:Phospholipids were extracted from cell pellets by successive addition of PBS pH 7.4, methanol, chloroform, and saline to a final ratio of 14:34:35:17. Evaporation of the organic layer yielded a lipid film that was dissolved in methanol and subjected to UPLC-MS/MS.
Extract Storage:-80℃

Combined analysis:

Analysis ID AN005315
Analysis type MS
Chromatography type Reversed phase
Chromatography system Waters Acquity H-Class
Column Waters ACQUITY UPLC BEH C8 (100 x 2.1mm,1.7um)
MS Type ESI
MS instrument type QTRAP
MS instrument name ABI Sciex 6500+
Ion Mode NEGATIVE
Units relative intensities

Chromatography:

Chromatography ID:CH004019
Chromatography Summary:Chromatographic separation of phospholipids was carried out on an Acquity BEH C8 column (1.7 μm, 2.1×100 mm, Waters, Milford, MA) using an Acquity UHPLC.
Instrument Name:Waters Acquity H-Class
Column Name:Waters ACQUITY UPLC BEH C8 (100 x 2.1mm,1.7um)
Column Temperature:45
Flow Gradient:The gradient was ramped from 75 to 85% B over 5 min and further increased to 100% B within 2 min, followed by isocratic elution for another 2 min
Flow Rate:0.75 mL/min
Solvent A:90% Water, 10% acetonitrile; 2 mM ammonium acetate
Solvent B:95% Acetonitrile, 5% Water; 2 mM ammonium acetate
Chromatography Type:Reversed phase

MS:

MS ID:MS005045
Analysis ID:AN005315
Instrument Name:ABI Sciex 6500+
Instrument Type:QTRAP
MS Type:ESI
MS Comments:Targeted MRM with pre-optimized settings and subsequent automated integration of selected signals using Analyst 1.6.3 or Analyst 1.7.1 (Sciex).
Ion Mode:NEGATIVE